Simultaneous Detection of Prolactin and Growth Hormone Using a Dual-label Time-resolved Fluorescence Immunoassay

被引:0
作者
Zhong, Shuhai [1 ]
Liang, Huankun [2 ]
Peng, Fenglan [3 ]
Lu, Yanhong [2 ]
Liu, Tiancai [4 ]
Kulchytski, Uladzimir [5 ]
Dong, Wenqi [6 ]
机构
[1] Guangzhou Youdi Biotechnol Co Ltd, Guangzhou 510663, Peoples R China
[2] Jinan Laide Biotechnol Co Ltd, Jinan 271100, Peoples R China
[3] Taian Disabled Soldiers Hosp Shandong Prov, Tai An 271099, Peoples R China
[4] Southern Med Univ, Sch Lab Med & Biotechnol, Guangzhou 510515, Guangdong, Peoples R China
[5] Natl Acad Sci Belarus, Inst Physiol, Minsk 220072, BELARUS
[6] Guangzhou Zhenda Biopharmaceut Technol Co Ltd, 3 Juquan Rd, Guangzhou 510663, Peoples R China
关键词
Prolactin; Growth hormone; Time-resolved fluorescence immunoassay; Serum; CANCER; DIAGNOSIS;
D O I
10.1007/s10895-023-03395-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Prolactin (PRL) and growth hormone (GH) are two important hormones secreted by the pituitary gland, and their abnormal levels are often related to disease status. This study aimed to establish a new dual-label time-resolved fluorescence immunoassay (TRFIA) to quantitatively measure PRL and GH levels in serum. A sandwich TRFIA was optimized and established: anti-PRL/GH antibodies immobilized on 96-well plates captured PRL/GH and then banded together with anti-PRL/GH paired antibodies labeled with europium(III) (Eu3+)/samarium(III) (Sm3+) chelates. Finally, a time-resolved analyzer measured the Eu3+/Sm3+ fluorescence values. Clinical serum samples were used to evaluate the detection performance of this method. The sensitivities of this dual-label TRFIA were 0.35 ng/mL and 0.45 ng/mL, respectively, and the detection range was between 0.1 and 1000 ng/mL. All the cross-reactivities were lower than 1.07%. The intra-assay and interassay coefficients of variation were 2.18-7.85% and 2.25-7.30%, respectively. Compared with the registered TRFIA kits, a high Pearson coefficient (r = 0.9626 and 0.9675) was observed. This dual-label TRFIA has high sensitivity, accuracy and specificity with good clinical detection performance, representing a suitable alternative to existing methods for determining PRL and GH levels, and is expected to be used in the clinic in the future.
引用
收藏
页码:1417 / 1422
页数:6
相关论文
共 50 条
[31]   Soluble Tim3 detection by time-resolved fluorescence immunoassay and its application in membranous nephropathy [J].
Chen, Ming ;
Wang, Liang ;
Wang, Yigang ;
Zhou, Xiumei ;
Liu, Xinyuan ;
Chen, Hao ;
Huang, Biao ;
Hu, Zhigang .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2020, 34 (06)
[32]   Development of a Time-Resolved Fluorescence Immunoassay for the Diagnosis of Hepatocellular Carcinoma Based on the Detection of Glypican-3 [J].
Chen, Juan-Juan ;
Xie, Chun-Mei ;
Wang, Cong-Rong ;
Wan, Yong ;
Dong, Zhi-Ning ;
Li, Ming ;
Xu, Wei-Wen .
JOURNAL OF FLUORESCENCE, 2017, 27 (04) :1479-1485
[33]   Establishment of growth stimulating gene 2 protein time-resolved fluorescence immunoassay and its application in sepsis [J].
Wang, Lu ;
Fu, Benqi ;
Xiang, Zhongyi ;
Chen, Xindong ;
Chen, Jianye ;
Qin, Yuan ;
Sheng, Huiming ;
Zhou, Xiumei ;
Li, Qian ;
Huang, Biao .
JOURNAL OF IMMUNOLOGICAL METHODS, 2023, 520
[34]   Time-resolved fluorescence lifetime for cutaneous melanoma detection [J].
Pires, Layla ;
Nogueira, Marcelo Saito ;
Pratavieira, Sebastiao ;
Moriyama, Lilian Tan ;
Kurachi, Cristina .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (09) :3080-3089
[35]   Determination of human COVID-19 total antibodies in serum using a time-resolved fluorescence immunoassay [J].
Xu, Yunjian ;
Chen, Cuicui ;
Lai, Hongrui ;
He, Ying ;
Guo, Guiling ;
Feng, Jianming ;
Li, Laiqing .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2022, 69 (04) :1474-1481
[36]   Sensitivity of Time-Resolved Fluorescence Analysis Methods for Disease Detection [J].
Agrawal, Anant ;
Gallas, Brandon D. ;
Parker, Camisha ;
Agrawal, Krishan M. ;
Pfefer, T. Joshua .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2010, 16 (04) :877-885
[37]   Establishment of a time-resolved immunoassay for acute kidney injury based on the detection of Kim-1 [J].
Shaoxiong, Zheng ;
Zhou, Xiumei ;
Qin, Yuan ;
Xiaomei, Yu ;
Lingli, Chen ;
Xiaobin, Liu ;
Wang, Yigang ;
Jianguang, Gong ;
Shuijuan, Shen ;
Huang, Biao .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (09)
[38]   Development of a rapid time-resolved fluorescence immunoassay for cannabidiol quantification in Cannabis sativa L [J].
Fan, Ziyan ;
Cai, Xianjie ;
Xu, Xiaojie ;
Cui, Xiaokang ;
Zhao, Lin ;
Chen, Jian ;
Xing, Sheng ;
Ding, Bo ;
Ren, Lihong ;
Meng, Xiaoli ;
Ji, Yuan ;
Tang, Gangling .
INDUSTRIAL CROPS AND PRODUCTS, 2025, 226
[39]   Assessment of Urinary Total Testosterone Production by a Highly Sensitive Time-Resolved Fluorescence Immunoassay [J].
Bao, Shihua ;
Peng, Yifeng ;
Sheng, Shile ;
Lin, Qide .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2008, 22 (06) :403-408
[40]   Sensitive Time-Resolved Fluorescence Immunoassay for Quantitative Determination of Oxyfluorfen in Food and Environmental Samples [J].
Sheng, En Ze ;
Tan, Yu Ting ;
Lu, Yu Xiao ;
Xiao, Yue ;
Li, Zhen Xi .
FRONTIERS IN CHEMISTRY, 2021, 8