Simultaneous Detection of Prolactin and Growth Hormone Using a Dual-label Time-resolved Fluorescence Immunoassay

被引:0
作者
Zhong, Shuhai [1 ]
Liang, Huankun [2 ]
Peng, Fenglan [3 ]
Lu, Yanhong [2 ]
Liu, Tiancai [4 ]
Kulchytski, Uladzimir [5 ]
Dong, Wenqi [6 ]
机构
[1] Guangzhou Youdi Biotechnol Co Ltd, Guangzhou 510663, Peoples R China
[2] Jinan Laide Biotechnol Co Ltd, Jinan 271100, Peoples R China
[3] Taian Disabled Soldiers Hosp Shandong Prov, Tai An 271099, Peoples R China
[4] Southern Med Univ, Sch Lab Med & Biotechnol, Guangzhou 510515, Guangdong, Peoples R China
[5] Natl Acad Sci Belarus, Inst Physiol, Minsk 220072, BELARUS
[6] Guangzhou Zhenda Biopharmaceut Technol Co Ltd, 3 Juquan Rd, Guangzhou 510663, Peoples R China
关键词
Prolactin; Growth hormone; Time-resolved fluorescence immunoassay; Serum; CANCER; DIAGNOSIS;
D O I
10.1007/s10895-023-03395-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Prolactin (PRL) and growth hormone (GH) are two important hormones secreted by the pituitary gland, and their abnormal levels are often related to disease status. This study aimed to establish a new dual-label time-resolved fluorescence immunoassay (TRFIA) to quantitatively measure PRL and GH levels in serum. A sandwich TRFIA was optimized and established: anti-PRL/GH antibodies immobilized on 96-well plates captured PRL/GH and then banded together with anti-PRL/GH paired antibodies labeled with europium(III) (Eu3+)/samarium(III) (Sm3+) chelates. Finally, a time-resolved analyzer measured the Eu3+/Sm3+ fluorescence values. Clinical serum samples were used to evaluate the detection performance of this method. The sensitivities of this dual-label TRFIA were 0.35 ng/mL and 0.45 ng/mL, respectively, and the detection range was between 0.1 and 1000 ng/mL. All the cross-reactivities were lower than 1.07%. The intra-assay and interassay coefficients of variation were 2.18-7.85% and 2.25-7.30%, respectively. Compared with the registered TRFIA kits, a high Pearson coefficient (r = 0.9626 and 0.9675) was observed. This dual-label TRFIA has high sensitivity, accuracy and specificity with good clinical detection performance, representing a suitable alternative to existing methods for determining PRL and GH levels, and is expected to be used in the clinic in the future.
引用
收藏
页码:1417 / 1422
页数:6
相关论文
共 50 条
[21]   Simultaneous determination of the cytokeratin 19 fragment and carcinoembryonic antigen in human serum by magnetic nanoparticle-based dual-label time-resolved fluoroimmunoassay [J].
Lin, Guanfeng ;
Zhao, Hui ;
Liu, Tiancai ;
Hou, Jingyuan ;
Ren, Zhiqi ;
Huang, Wenhua ;
Dong, Wenqi ;
Wu, Yingsong .
RSC ADVANCES, 2014, 4 (98) :55229-55236
[22]   Development and validation of a time-resolved fluorescence immunoassay for the detection of anti-Toxoplasma gondii antibodies in goats [J].
Huertas-Lopez, Ana ;
Martinez-Subiela, Silvia ;
Joaquin Ceron, Jose ;
Vazquez-Calvo, Angela ;
Danilo Pazmino-Bonilla, Elvis ;
Maria Lopez-Urena, Nadia ;
Martinez-Carrasco, Carlos ;
Alvarez-Garcia, Gema .
VETERINARY PARASITOLOGY, 2021, 293
[23]   A New Method for Detection African Swine Fever Virus: Time-resolved Fluorescence Immunoassay [J].
Cuicui Chen ;
Hongrui Lai ;
Huankun Liang ;
Ying He ;
Guiling Guo ;
Laiqing Li .
Journal of Fluorescence, 2021, 31 :1291-1296
[24]   Residues determination of carbofuran in vegetables based on sensitive time-resolved fluorescence immunoassay [J].
Gui, Wenjun ;
Jin, Maojun ;
Sun, Lifeng ;
Guo, Yirong ;
Zhu, Guonian .
FOOD AND AGRICULTURAL IMMUNOLOGY, 2009, 20 (01) :49-56
[25]   Establishment and Clinical Application in Stroke of a Serum Copeptin Time-Resolved Fluorescence Immunoassay [J].
Zhou, Zixuan ;
Sun, Fan ;
Jiang, Jingwen ;
Dou, Zhijie ;
Lv, Yinglei ;
Zhang, Zhimin ;
Zhou, Xiumei ;
Zhao, Xueqin ;
Qin, Yuan ;
Huang, Biao .
JOURNAL OF FLUORESCENCE, 2024, 34 (05) :2349-2358
[26]   Quantification of apolipoprotein D by an immunoassay with time-resolved fluorescence spectroscopy [J].
Knipping, G ;
GoggFassolter, G ;
Frohnwieser, B ;
Krempler, F ;
Kostner, GM ;
Malle, E .
JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 202 (01) :85-95
[27]   Simultaneous detection of imidacloprid and parathion by the dual-labeled time-resolved fluoroimmunoassay [J].
Shi, Haiyan ;
Sheng, Enze ;
Feng, Lu ;
Zhou, Liangliang ;
Hua, Xiude ;
Wang, Minghua .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (19) :14882-14890
[28]   Rapid diagnosis of Tobacco mosaic virus in tobacco using time-resolved fluorescence immunoassay [J].
Ji, Yuan ;
Guo, Yushuang ;
Deng, Huimin ;
Zhang, Jianfeng ;
Wang, Yuemao ;
Dai, En ;
Fan, Ziyan ;
Tang, Gangling ;
Jia, Mengao ;
Ding, Bo .
FOOD AND AGRICULTURAL IMMUNOLOGY, 2023, 34 (01) :10-20
[29]   Development of a time-resolved fluorescence immunoassay based on immunomagnetic beads for gastrin-17 [J].
Zheng, Shaoxiong ;
Hu, Renjing ;
Yu, Xiaomei ;
Chen, Lingli ;
Wang, Binrong ;
Qin, Yuan ;
Zhou, Xiumei ;
Wang, Yigang ;
Huang, Biao ;
Fang, Hongming ;
Liu, Pengfei .
JOURNAL OF IMMUNOLOGICAL METHODS, 2021, 499
[30]   Comparative performance of five recombinant and chimeric antigens in a time-resolved fluorescence immunoassay for detection of Toxoplasma gondii infection in cats [J].
Huertas-Lopez, Ana ;
Rojo, Marinela Contreras ;
Sukhumavasi, Woraporn ;
Martinez-Subiela, Silvia ;
Alvarez-Garcia, Gema ;
Lopez-Urena, Nadia Maria ;
Ceron, Jose Joaquin ;
Martinez-Carrasco, Carlos .
VETERINARY PARASITOLOGY, 2022, 304