Seismic fragility assessment of reinforced concrete moment frames retrofitted with strongback braced system

被引:10
作者
Azandariani, Mojtaba Gorji [1 ]
Azandariani, Ali Gorji [2 ]
Rousta, Ali Mohammad [3 ]
Nia, Hamid Malek [4 ]
机构
[1] Semnan Univ, Fac Civil Engn, Struct Engn Div, Semnan, Iran
[2] Iran Univ Sci & Technol, Sch Railway Engn, Tehran, Iran
[3] Univ Yasuj, Dept Civil Engn, Yasuj, Iran
[4] Islamic Azad Univ, Dept Civil Engn, Arak Branch, Arak, Iran
关键词
Strongback braced (SB) system; Reinforced concrete moment frames (RCMF); Strengthening; Retrofit; Incremental static/dynamic analysis; Seismic fragility analysis; ENERGY-DISSIPATION SYSTEM; BASE-ISOLATION; RC FRAMES; BUILDINGS; BEHAVIOR;
D O I
10.1016/j.rineng.2023.101504
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study focused on analysing the seismic fragility and retrofitting of reinforced concrete flexural frames using strongback braced system. Using the steel strongback braced system as a means of seismically strengthening and retrofitting reinforced concrete moment frames (RCMFs), this research aims to enhance the effectiveness of RCMFs. In this study, RCMFs of 5-, 10-, and 15-stories are designed according to the first and fourth editions of the Iran Earthquake Standard 2800. The RCMFs designed according to the first edition are strengthened and reinforced using the SB system. The studied structures were analyzed under incremental static loading and time history analysis. The results show that the yield force and maximum base shear for the structures designed with the fourth edition, compared to the structures designed with the first edition, have increased by 1.28-1.42. This demonstrates the necessity of improving structures constructed according to the first edition. Meanwhile, the results of the retrofitted structures with strongback braces show the same or better performance than newly designed structures. The results of the fragility analysis show that the addition of the strong bracing system significantly improves the performance of the structures and brings them closer to the 4th edition standards. The retrofitting system reduces drift ratio between floors and reduces structural damage.
引用
收藏
页数:18
相关论文
共 55 条
[34]   Base-isolation systems for the seismic retrofitting of r.c. framed buildings with soft-storey subjected to near-fault earthquakes [J].
Mazza, Fabio ;
Mazza, Mirko ;
Vulcano, Alfonso .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 109 :209-221
[35]   Seismic retrofitting by base-isolation of r.c. framed buildings exposed to different fire scenarios [J].
Mazza, Fabio ;
Mazza, Mirko .
EARTHQUAKES AND STRUCTURES, 2017, 13 (03) :267-277
[36]  
McCormick J., 2008, P 14 WORLD C EARTHQU
[37]   Investigation of seismic behavior of the reinforced concrete wall-frame system on a flexible bed [J].
Moosavi, Seyyed Mostafa Ayatollahi ;
Mirhoseini, Ramin Tabatabaei ;
Kebriaie, Mohamadhosein .
RESULTS IN ENGINEERING, 2022, 15
[38]   Analytical and numerical study of concrete slabs reinforced by steel rebars and perforated steel plates under blast loading [J].
Peyman, S. ;
Eskandari, A. .
RESULTS IN ENGINEERING, 2023, 19
[39]   A new hybrid energy dissipation system with viscoelastic and flexural yielding strips dampers for multi-level vibration control [J].
Ranaei, Omid ;
Aghakouchak, Ali Akbar .
ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2019, 19 (02) :584-597
[40]  
Rousta A.M., 2023, J. Rehabil. Civ. Eng., V11, P122, DOI [10.22075/JRCE.2022.26848.1639, DOI 10.22075/JRCE.2022.26848.1639]