Background:Despite surgical fixation, the scaphoid nonunion rate remains at 3% to 5%. Recent biomechanical studies have demonstrated increased stability with 2-screw constructs. The objective of our study is to determine the preliminary union rate and anatomic feasibility of 2-screw surgical fixation for scaphoid fractures.Methods:This study is a retrospective case series of 25 patients (average age 32 years) with scaphoid fractures treated with 2 parallel headless compression screws (HCS). Postoperative evaluation included Mayo Wrist Score (MWS), range of motion, time to union, and return to activity. Bivariate analysis for gender and Pearson correlation coefficient for body size (height, weight, and body mass index) was conducted against radiographically measured scaphoid width, screw lengths, and the distance between the 2 screws.Results:All fractures healed with an average time to union of 9.9 weeks (median 7.6 weeks; range: 4.1-28.3). The mean MWS was 93.3 (range: 55-100), with 3 complications (12%), one of which affected the outcome of the surgery. The bivariate analysis demonstrated that the female gender was associated with significantly smaller scaphoid width (P = .004) but a similar distance between the 2 screws (P = .281). The distance between the 2 screws and the body size demonstrated a weak-to-no correlation.Conclusions:The 2-screw construct for scaphoid fracture achieved a favorable union rate and clinical outcome. Gender was the only variable significantly associated with scaphoid width and screw length. The distance between the screws was constant regardless of gender and body size, indicating that the technique for parallel screw placement can remain consistent.Type of Study:Therapeutic.Level of Evidence:Level IV.
引用
收藏
页码:1267 / 1274
页数:8
相关论文
共 41 条
  • [31] Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures
    Zhang, Ru-Yi
    Zhang, Wu-Peng
    Yang, Guang-Min
    Wang, Dao-Feng
    Su, Peng
    Zhang, Yi
    Nie, Shao-Bo
    Li, Jia
    Zhao, Zhe
    Li, Jian-Tao
    Zhang, Li-Cheng
    Tang, Pei-Fu
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 953 - 964
  • [32] Clinical analysis of internal fixation femoral neck fractures with two or three canulated screws
    Kostic, Igor M.
    Mitkovic, Milan M.
    Milenkovic, Sasa S.
    Mitkovic, Milorad B.
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2021, 149 (7-8) : 428 - 434
  • [33] Short-Term Clinical and Radiographic Outcome after Stabilization of Femoral Capital Physeal Fractures with Cortical Positional Screws in 39 Cats
    Vink, Joris Johannes Wilhelmus Gerardus
    Hubers, Mike Willem Laurens
    den Hertog, Erik
    Schaeffer, Ingrid Geraldine Fernanda
    van Zuilen, Dick
    Maarschalkerweerd, Roelof Jozef
    van Klaveren, Nicolien Jacoba
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 35 (06) : 403 - 412
  • [34] Open reduction internal fixation of displaced transverse patella fractures with figure-eight wiring through parallel cannulated compression screws
    Berg, EE
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (08) : 573 - 576
  • [35] External Fixation as a Definitive Treatment for Humeral Shaft Fractures: Radiographic and Functional Results With Analysis of Outcome Predictors
    Costa, Giovan Giuseppe
    Aloj, Domenico Costantino
    Cerbasi, Simone
    Rizzo, Maria
    Masse, Alessandro
    Pascarella, Raffaele
    Mariconda, Massimo
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (07) : 354 - 360
  • [36] Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis
    Zhong, Zhou
    Lan, Xuejun
    Xiang, Zhou
    Duan, Xin
    CLINICAL BIOMECHANICS, 2023, 108
  • [37] Is stability of femoral neck fractures in the inverted triangle configuration related to the angle between the fracture line and the cannulated compression screws? A finite element analysis
    Niu, Zhipeng
    Wang, Qian
    Yuan, Baoming
    Cui, Yutao
    Ren, Guangkai
    Wu, Dankai
    Peng, Chuangang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [38] Dhs plus anti-rotational screw vs cannulated screws for femoral neck fractures: an analysis of clinical outcome and incidence regarding avn
    Bisaccia, Michele
    Ceccarini, Paolo
    Rinonapoli, Giuseppe
    Di Giacomo, Lorenzo Maria
    Teodori, Julien
    Schiavone, Andrea
    Vicente, Cristina Ibanez
    De Trana, Giuseppe
    Caraffa, Auro
    ACTA ORTHOPAEDICA BELGICA, 2018, 84 (03): : 279 - 283
  • [39] Analysis of two minimally invasive procedures for osteoporotic vertebral compression fractures with intravertebral cleft: a systematic review and meta-analysis
    Wei, Hongyu
    Dong, Chunke
    Zhu, Yuting
    Ma, Haoning
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [40] Assessment of Two Measurement Techniques of Cervical Spine and C1-C2 Rotation in the Outcome Research of Axis Fractures A Morphometrical Analysis Using Dynamic Computed Tomography Scanning
    Koller, Heiko
    Resch, Herbert
    Acosta, Frank
    Zenner, Juliane
    Schwaiger, Robert
    Tauber, Mark
    Forstner, Rosemarie
    Lederer, Stefan
    Auffarth, Alexander
    Hitzl, Wolfgang
    SPINE, 2010, 35 (03) : 286 - 290