Two Parallel Headless Compression Screws for Scaphoid Fractures: Radiographic Analysis and Preliminary Outcome

被引:2
|
作者
Diprinzio, Eliseo V. [1 ]
Dieterich, James D. [1 ]
Walsh, Amanda L. [1 ]
Warburton, Andrew J. [1 ]
Chang, Andy L. [1 ]
Hausman, Michael R. [1 ]
Kim, Jaehon M. [1 ,2 ]
机构
[1] Icahn Sch Med Mt Sinai, New York, NY USA
[2] Icahn Sch Med Mt Sinai, 425 West 59th St,5th Floor, New York, NY 10019 USA
来源
HAND-AMERICAN ASSOCIATION FOR HAND SURGERY | 2023年 / 18卷 / 08期
关键词
scaphoid fractures; headless compression screws; 2-screw construct; INTERNAL-FIXATION; DISPLACED FRACTURES; OPEN REDUCTION; WAIST; IMMOBILIZATION; MANAGEMENT; NONUNION; DELAYS;
D O I
10.1177/15589447221081879
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background:Despite surgical fixation, the scaphoid nonunion rate remains at 3% to 5%. Recent biomechanical studies have demonstrated increased stability with 2-screw constructs. The objective of our study is to determine the preliminary union rate and anatomic feasibility of 2-screw surgical fixation for scaphoid fractures.Methods:This study is a retrospective case series of 25 patients (average age 32 years) with scaphoid fractures treated with 2 parallel headless compression screws (HCS). Postoperative evaluation included Mayo Wrist Score (MWS), range of motion, time to union, and return to activity. Bivariate analysis for gender and Pearson correlation coefficient for body size (height, weight, and body mass index) was conducted against radiographically measured scaphoid width, screw lengths, and the distance between the 2 screws.Results:All fractures healed with an average time to union of 9.9 weeks (median 7.6 weeks; range: 4.1-28.3). The mean MWS was 93.3 (range: 55-100), with 3 complications (12%), one of which affected the outcome of the surgery. The bivariate analysis demonstrated that the female gender was associated with significantly smaller scaphoid width (P = .004) but a similar distance between the 2 screws (P = .281). The distance between the 2 screws and the body size demonstrated a weak-to-no correlation.Conclusions:The 2-screw construct for scaphoid fracture achieved a favorable union rate and clinical outcome. Gender was the only variable significantly associated with scaphoid width and screw length. The distance between the screws was constant regardless of gender and body size, indicating that the technique for parallel screw placement can remain consistent.Type of Study:Therapeutic.Level of Evidence:Level IV.
引用
收藏
页码:1267 / 1274
页数:8
相关论文
共 41 条
  • [1] A comparison of two headless compression screws for operative treatment of scaphoid fractures
    Grewal, Ruby
    Assini, Joseph
    Sauder, David
    Ferreira, Louis
    Johnson, Jim
    Faber, Kenneth
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2011, 6
  • [2] Stabilization of scaphoid type B2 fractures with one or two headless compression screws
    Quadlbauer, S.
    Beer, T.
    Pezzei, Ch.
    Jurkowitsch, J.
    Tichy, A.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (11) : 1587 - 1595
  • [3] Headless Compression Screw Fixation of Scaphoid Fractures
    Fowler, John R.
    Ilyas, Asif M.
    HAND CLINICS, 2010, 26 (03) : 351 - +
  • [4] Two-level fixation with headless compression screws for tibial plateau fractures
    Wagner, Robert Kaspar
    Kloen, Peter
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (06) : 4683 - 4698
  • [5] Treatment of scaphoid waist nonunion by one, two headless compression screws or plate with or without additional extracorporeal shockwave therapy
    Quadlbauer, S.
    Pezzei, Ch.
    Beer, T.
    Jurkowitsch, J.
    Keuchel, T.
    Schlintner, C.
    Schaden, W.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (02) : 281 - 293
  • [6] Arthroscopic treatment of unstable scaphoid fracture and nonunion with two headless compression screws and distal radius bone graft
    Cheng, Cong
    Jiang, Zongyuan
    Sun, Haoran
    Hu, Jiaping
    Ouyang, Yanggang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [7] Scaphoid Nonunions Treated With 2 Headless Compression Screws and Bone Grafting
    Garcia, Ryan M.
    Leversedge, Fraser J.
    Aldridge, J. Mack
    Richard, Marc J.
    Ruch, David S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (07): : 1301 - 1307
  • [8] Fixation of Hand Fractures with Intramedullary Headless Compression Screws
    Dohse, Nicolas M.
    Jones, Christopher M.
    Ilyas, Asif M.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2022, 10 (12): : 1004 - 1012
  • [9] Which is the Best Solution for Achieving Maximal Interfragmentary Compression of the Scaphoid Fractures - One or Two Herbert Screws?
    Simeonov, L.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2023, 90 (01) : 34 - 40
  • [10] Four-corner arthrodesis using two headless compression screws
    Iordache, Sorin Daniel
    Nam, Diane
    Peylan, Jacques
    Axelrod, Terry
    ACTA ORTHOPAEDICA BELGICA, 2016, 82 (02): : 332 - 338