Comparison of volumetric modulated arc therapy and helical tomotherapy for prostate cancer using Pareto fronts

被引:1
作者
Wuthrich, Diana [1 ,2 ]
Wang, Zirun [1 ,2 ]
Zeverino, Michele [1 ,2 ]
Bourhis, Jean [2 ,3 ]
Bochud, Francois [1 ,2 ]
Moeckli, Raphal [1 ,2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Lausanne Univ, Lausanne, Switzerland
[3] Lausanne Univ Hosp, Dept Radiat Oncol, Lausanne, Switzerland
关键词
helical tomotherapy (HT); multi-criteria optimization (MCO); pareto front; prostate; volumetric modulated arc therapy (VMAT); SINGLE-ARC; PLAN QUALITY; RADIOTHERAPY; IMRT; VMAT; OPTIMIZATION; IRRADIATION; TOXICITY;
D O I
10.1002/mp.16868
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundStudies comparing different radiotherapy treatment techniques-such as volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT)-typically compare one treatment plan per technique. Often, some dose metrics favor one plan and others favor the other, so the final plan decision involves subjective preferences. Pareto front comparisons provide a more objective framework for comparing different treatment techniques. A Pareto front is the set of all treatment plans where improvement in one criterion is possible only by worsening another criterion. However, different Pareto fronts can be obtained depending on the chosen machine settings.PurposeTo compare VMAT and HT using Pareto fronts and blind expert evaluation, to explain the observed differences, and to illustrate limitations of using Pareto fronts.MethodsWe generated Pareto fronts for twenty-four prostate cancer patients treated at our clinic for VMAT and HT techniques using an in-house script that controlled a commercial treatment planning system. We varied the PTV under-coverage (100% - V95%) and the rectum mean dose, and fixed the mean doses to the bladder and femoral heads. In order to ensure a fair comparison, those fixed mean doses were the same for the two treatment techniques and the sets of objective functions were chosen so that the conformity indexes of the two treatment techniques were also the same. We used the same machine settings as are used in our clinic. Then, we compared the VMAT and HT Pareto fronts using a specific metric (clinical distance measure) and validated the comparison using a blinded expert evaluation of treatment plans on these fronts for all patients in the cohort. Furthermore, we investigated the observed differences between VMAT and HT and pointed out limitations of using Pareto fronts.ResultsBoth clinical distance and blind treatment plan comparison showed that VMAT Pareto fronts were better than HT fronts. VMAT fronts for 10 and 6 MV beam energy were almost identical. HT fronts improved with different machine settings, but were still inferior to VMAT fronts.ConclusionsThat VMAT Pareto fronts are better than HT fronts may be explained by the fact that the linear accelerator can rapidly vary the dose rate. This is an advantage in simple geometries that might vanish in more complex geometries. Furthermore, one should be cautious when speaking about Pareto optimal plans as the best possible plans, as their calculation depends on many parameters.
引用
收藏
页码:3010 / 3019
页数:10
相关论文
共 49 条
  • [1] An objective function for radiation treatment optimization based on local biological measures
    Alber, M
    Nüsslin, F
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02) : 479 - 493
  • [2] [Anonymous], 1999, 62 ICRU
  • [3] [Anonymous], 1993, 50 ICRU, DOI 10.1118/1.597396
  • [4] IMRT: a review and preview
    Bortfeld, Thomas
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13) : R363 - R379
  • [5] Reply to 'Letter to the Editor on 'Single-Arc IMRT?''
    Bortfeld, Thomas
    Webb, Steve
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08) : L43 - L44
  • [6] Single-Arc IMRT?
    Bortfeld, Thomas
    Webb, Steve
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01) : N9 - N20
  • [7] Multi-criteria optimization and decision-making in radiotherapy
    Breedveld, Sebastiaan
    Craft, David
    van Haveren, Rens
    Heijmen, Ben
    [J]. EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2019, 277 (01) : 1 - 19
  • [8] The equivalence of multi-criteria methods for radiotherapy plan optimization
    Breedveld, Sebastiaan
    Storchi, Pascal R. M.
    Heijmen, Ben J. M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (23) : 7199 - 7209
  • [9] Static and rotational intensity modulated techniques for head-neck cancer radiotherapy: A planning comparison
    Broggi, Sara
    Perna, Lucia
    Bonsignore, Francesco
    Rinaldin, Giuseppe
    Fiorino, Claudio
    Chiara, Anna
    Frigerio, Cristina
    Butti, Ivana
    Sangalli, Giulia
    Dell'Oca, Italo
    Di Muzio, Nadia
    Cattaneo, Giovanni Mauro
    Declich, Fausto
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (08): : 973 - 979
  • [10] Comparison of plan quality provided by intensity-modulated arc therapy and helical tomotherapy
    Cao, Daliang
    Holmes, Timothy W.
    Afghan, Muhammad K. N.
    Shepard, David M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 240 - 250