Small-field Dosimetry of 6-and 10-MV Flattening Filter-free and Flattening Filter Photon Beams for Therapeutic Use

被引:0
作者
Shukla, Jooli [1 ]
Dwivedi, Shekhar [2 ]
Kansal, Sandeep [3 ]
Dangwal, Vinod Kumar [4 ]
Tiwari, K. P. [1 ]
Singla, Amit Kumar [3 ]
Rani, Supriya [3 ]
机构
[1] Dr Bhimrao Ambedkar Univ, Agra Coll, Dept Phys, Agra 282004, India
[2] Homi Bhabha Canc Hosp & Res Ctr, Tata Mem Ctr, Dept Med Phys, New Chandigarh Mullanpur 140901, Punjab, India
[3] Maharaja Ranjit Singh Punjab Tech Univ, Dept Phys, Bathinda 151001, India
[4] Govt Med Coll, Dept Radiotherapy, Patiala 147001, Punjab, India
关键词
Small-field dosimetry; flattening filter free beam; Output Factor; Penumbra; Surface dose; MONTE-CARLO; RADIOCHROMIC FILM; DETECTORS; PENUMBRA; IMPROVEMENT;
D O I
10.56042/ijpap.v61i10.2827
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This investigation aimed to measure and commission small unflat photon beams using the detectors described in our previous study10. Furthermore, the dosimetric parameters of small-field unflat and flat photon beams were compared to provide a better interpretation of beam energy and spectrum. The TrueBeam linear accelerator (TrueBeam LINAC, Varian Medical Systems) was employed in this study. The 10 and 6 MV unflat and flat photon beams were used to measure the output factor, depth dose, and beam profile of small-fields ranging in size from 1 cm x 1 cm to 6 cm x 6 cm. All measurements were performed according to the TRS-483 protocols established by the International Atomic Energy Agency. For both 10 and 6 MV, the output factors in unflat beam were significantly higher than in flat beam. The study found that unflat beam penumbras were slightly smaller than flat beam penumbras for both photon energies, which may improve tumor conformity and reduce doses to normal organs. The unflat photon beams had higher suface doses and lower depth doses at 10 cm than the flat photon beams for both energies, leading to considerably more beam energy degradation for unflat beams. The findings of this work are consistent with previously published data, and they will be useful for future research and LINAC commissioning.
引用
收藏
页码:846 / 850
页数:5
相关论文
共 26 条
  • [1] Small-field dosimetry of TrueBeamTM flattened and flattening filter-free beams: A multi-institutional analysis
    Akino, Yuichi
    Mizuno, Hirokazu
    Isono, Masaru
    Tanaka, Yoshihiro
    Masai, Norihisa
    Yamamoto, Toshijiro
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 78 - 87
  • [2] The characterization of unflattened photon beams from a 6 MV linear accelerator
    Cashmore, Jason
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (07) : 1933 - 1946
  • [3] A Monte Carlo study of a flattening filter-free linear accelerator verified with measurements
    Dalaryd, Marten
    Kragl, Gabriele
    Ceberg, Crister
    Georg, Dietmar
    McClean, Brendan
    af Wetterstedt, Sacha
    Wieslander, Elinore
    Knoos, Tommy
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23) : 7333 - 7344
  • [4] Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors
    Dieterich, Sonja
    Sherouse, George W.
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 4166 - 4173
  • [5] Dosimetric characteristics of an unshielded p-type Si diode: linearity, photon energy dependence and spatial resolution
    Djouguela, Armand
    Griessbach, Irmgard
    Harder, Dietrich
    Kollhoff, Ralf
    Chofor, Ndimofor
    Ruehmann, Antje
    Willborn, Kay
    Poppe, Bjoern
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (04): : 301 - 306
  • [6] Dosimetry of a 6 MV flattening filter-free small photon beam using various detectors
    Dwivedi, Shekhar
    Kansal, Sandeep
    Dangwal, Vinod Kumar
    Bharati, Avinav
    Shukla, Jooli
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04):
  • [7] Calculation of kQclin,Qmsrfclin,fmsr for several small detectors and for two linear accelerators using Monte Carlo simulations
    Francescon, P.
    Cora, S.
    Satariano, N.
    [J]. MEDICAL PHYSICS, 2011, 38 (12) : 6513 - 6527
  • [8] Small photon beam measurements using radiochromic film and Monte Carlo simulations in a water phantom
    Garcia-Garduno, Olivia A.
    Larraga-Gutierrez, Jose M.
    Rodriguez-Villafuerte, Mercedes
    Martinez-Davalos, Arnulfo
    Celis, Miguel A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 (02) : 250 - 253
  • [9] Current status and future perspective of flattening filter free photon beams
    Georg, Dietmar
    Knoos, Tommy
    McClean, Brendan
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1280 - 1293
  • [10] Dosimetric properties of a beam quality-matched 6 MV unflattened photon beam
    Huang, Yunfei
    Siochi, R. Alfredo
    Bayouth, John E.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (04): : 71 - 81