Removal of harmful oxyanions from contaminated water by Donnan dialysis

被引:4
作者
Akula, Vishnu V. [1 ]
Philip, Ligy [1 ]
机构
[1] IIT Madras, Dept Civil Engn, Environm Engn Div, Chennai 600036, India
关键词
Oxyanion; Donnan dialysis; Anion exchange membranes; FAD PET 75; FAS PET 75; Predictive kinetic modelling; NITRATE REMOVAL; ANION-EXCHANGE; WASTE-WATER; PERCHLORATE; REGENERATION; GROUNDWATER; REDUCTION; MEMBRANES; RESIN;
D O I
10.1016/j.jwpe.2023.104085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The removal of oxyanions like nitrate, sulphate, phosphate, chromate and perchlorate was investigated in single, binary and multi-component feed systems using Donnan dialysis across two homogeneous anion exchange membranes, FAD PET 75 and FAS PET 75. The ion exchange isotherms were established for oxyanion - chloride binary systems with both anion exchange membranes. The effect of initial concentration, recirculation flow rate, and receiver salt concentration was examined with FAD PET 75. The overall kinetic coefficient was calculated from the flux equation and was used to compare the transport kinetics of different oxyanions. The kinetics of oxyanions removal followed the order of nitrate > perchlorate > chromate > sulphate > phosphate, which can be attributed to the hydrated radius and structure of the oxyanions. The presence of co-existing oxyanions did not show a significant effect on the removal of nitrate, perchlorate, and chromate while sulphate and phosphate were influenced by their presence. Based on the present study, FAD PET 75 was able to remove all the target oxyanions effectively whereas FAS PET 75 was ineffective in the removal of sulphate and phosphate because of the higher cross linkage of the matrix which was evident with its lower water content.
引用
收藏
页数:12
相关论文
共 58 条
[21]   Simple Model for Characterizing a Donnan Dialysis Process [J].
Hasson, David ;
Beck, Adam ;
Fingerman, Fiana ;
Tachman, Chen ;
Shemer, Hilla ;
Semiat, Raphael .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (14) :6094-6102
[22]  
Helfferich F., 1962, ION EXCHANGE
[23]  
Hong Young-Seoub, 2014, J Prev Med Public Health, V47, P245, DOI 10.3961/jpmph.14.035
[24]   Development of a predictive kinetic model with statistically analyzed parameters for Donnan Dialysis process [J].
Huang, Yunyan ;
Sagiv, Abraham ;
Semiat, Raphael ;
Shemer, Hilla .
JOURNAL OF MEMBRANE SCIENCE, 2022, 663
[25]   Nitrate removal from groundwater: a review of natural and engineered processes [J].
Huno, Solomon K. M. ;
Rene, Eldon R. ;
van Hullebusch, Eric D. ;
Annachhatre, Ajit P. .
JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2018, 67 (08) :885-902
[26]   A mechanistic approach of chromium (VI) adsorption onto manganese oxides and boehmite [J].
Islam, Md. Aminul ;
Angove, Michael J. ;
Morton, David W. ;
Pramanik, Biplob Kumar ;
Awual, Md. Rabiul .
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2020, 8 (02)
[27]   Perchlorate as an emerging contaminant in soil, water and food [J].
Kumarathilaka, Prasanna ;
Oze, Christopher ;
Indraratne, S. P. ;
Vithanage, Meththika .
CHEMOSPHERE, 2016, 150 :667-677
[28]   Comparative study of nanofiltration and ion exchange for nitrate reduction in the presence of chloride and iron in groundwater [J].
Labarca, Francisca ;
Borquez, Rodrigo .
SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 723
[29]   Removal of oxyanions from synthetic wastewater via carbonation process of calcium hydroxide: Applied and fundamental aspects [J].
Montes-Hernandez, G. ;
Concha-Lozano, N. ;
Renard, F. ;
Quirico, E. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 166 (2-3) :788-795
[30]   Simultaneous removal of chromate and phosphate using different operational combinations for their adsorption on dolomite and banana peel [J].
Natalia Piol, M. ;
Dickerman, Carolina ;
Pilar Ardanza, M. ;
Saralegui, Andrea ;
Boeykens, Susana P. .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2021, 288 (288)