Rapid and Simultaneous Determination of 238Pu, 239Pu, 240Pu, and 241Pu in Samples with High-Level Uranium Using ICP-MS/MS and Extraction Chromatography

被引:6
作者
Huang, Zhao [1 ,3 ]
Hou, Xiaolin [1 ,2 ,5 ]
Zhao, Xue [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Inst Earth Environm, Xian AMS Ctr, Shaanxi Key Lab Accelerator Mass Spectrometry,Stat, Xian 710061, Peoples R China
[2] Pilot Natl Lab Marine Sci & Technol Qingdao, Open Studio Ocean Continental Climate & Environm C, Qingdao 266061, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Xian Inst Innovat Earth Environm Res, Xian 710061, Peoples R China
[5] Tech Univ Denmark, Dept Environm & Resource Engn, DK-4000 Roskilde, Denmark
基金
中国国家自然科学基金;
关键词
PLASMA-MASS SPECTROMETRY; PLUTONIUM ISOTOPES; PU ISOTOPES; ENVIRONMENTAL-SAMPLES; SEDIMENT SAMPLES; SOIL; AM; MS; RADIONUCLIDES; ACTINIDES;
D O I
10.1021/acs.analchem.3c02526
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As the most important plutonium isotopes, Pu-238, Pu-239, Pu-240, and Pu-241 arenormallymeasured by two to three techniques, which are tedious, time-consuming,and not suitable for rapid analysis in emergency situations. Recently,ICP-MS has become a competitive technique for the rapid measurementof Pu-239, Pu-240, and Pu-241. However,ICP-MS is difficult to measure Pu-238 due to the seriousisobaric interference of U-238. This work reports a rapidanalytical method to solve this problem for the simultaneous determinationof Pu-238, Pu-239, Pu-240, and Pu-241 using triple-quadrupole inductively coupled plasma massspectrometry (ICP-MS/MS) combined with chemical separation. Chemicalseparation achieved a high decontamination factor of 2.12 x 10(9) for the most critical interfering element, uranium, by usingtwo sequential TK200 columns. The interferences of (UH+)-U-238-H-1 and U-238(+) were effectivelyeliminated by using 12 mL/min He-6 mL/min NH3 asthe reaction gases in the octupole collision/reaction cell in ICP-MS/MS.Combined with chemical separation, the overall elimination efficiencyof (UH+)-U-238-H-1 reached 3.6 x 10(17), which is 10(5) times better than the reportedmethod. With the high U-238(+) elimination efficiencyof 1.12 x 10(4) in the ICP-MS/MS measurement, the overallremoval efficiency of U-238(+) reached 10(13), guaranteeing accurate determination of femtogram-level Pu-238 as well as Pu-239, Pu-240, and Pu-241 in the samples containing milligram-level U-238. Thedetection time is reduced to minutes, well fulfilling the requirementof rapid analysis. This method is validated by analyzing the standardreference material and the spiked samples.
引用
收藏
页码:12931 / 12939
页数:9
相关论文
共 50 条
  • [41] Determination of Femtogram-Level Plutonium Isotopes in Environmental and Forensic Samples with High-Level Uranium Using Chemical Separation and ICP-MS/MS Measurement
    Hou, Xiaolin
    Zhang, Weichao
    Wang, Yanyun
    ANALYTICAL CHEMISTRY, 2019, 91 (18) : 11553 - 11561
  • [42] Retrospective determination of fallout radionuclides and 236U/238U, 233U/236U and 240Pu/239Pu atom ratios on air filters from Vienna and Salzburg, Austria
    Wallner, G.
    Uguz, H.
    Kern, M.
    Jirsa, F.
    Hain, K.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2022, 255
  • [43] Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation
    Huang, Zhaoya
    Ni, Youyi
    Wang, Hai
    Zheng, Jian
    Yamazaki, Shinnosuke
    Sakaguchi, Aya
    Long, Xinggui
    Uchida, Shigeo
    MICROCHEMICAL JOURNAL, 2019, 148 : 597 - 604
  • [44] A rapid method for quantifying 238Pu in the presence of natural 238U via quadrupole inductively coupled plasma mass spectrometry (ICP-MS) and utilizing a resin-based extraction procedure
    Ling Ying Diane Tiong
    Mer Lin Doris Ho
    Boon Kin Pong
    Richard D. Webster
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 314 : 1347 - 1351
  • [45] Sequential chemical separations and multiple ion counting ICP-MS for 241Pu–241Am–237Np dating of environmental collections on a single aliquot
    Steven J. Goldstein
    Kimberly A. Hinrichs
    Andrew J. Nunn
    Daniel W. Gurganus
    Ronald S. Amato
    Warren J. Oldham
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 318 : 695 - 701
  • [46] Limiting spectroscopic interferences of 239Pu and 237Np in a UO2 matrix using LA-ICP-MS
    Campbell, Keri
    Unger, Aaron
    Kerlin, William
    Hartmann, Thomas
    Bertoia, Julie
    Judge, Elizabeth
    Dirmyer, Matthew
    Czerwinski, Ken
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 310 (02) : 533 - 540
  • [47] CROSS-SECTION CALCULATIONS OF PHOTOFISSION REACTIONS FOR 238,239,240,241,242,244Pu ISOTOPES USING NUCLEAR LEVEL DENSITY
    Canbula, D.
    Canbula, B.
    NUCLEAR PHYSICS AND ATOMIC ENERGY, 2022, 23 (01) : 5 - 11
  • [48] Determination of ultra-trace Pu isotopes in large-volume seawater samples from the South Pacific Ocean using sector field ICP-MS combined with extraction chromatography
    Gu, Xiang
    Yang, Bo
    Yang, Guosheng
    Yamada, Masatoshi
    Wu, Fengchang
    Zheng, Jian
    MICROCHEMICAL JOURNAL, 2025, 208
  • [49] Rapid and simultaneous determination of neptunium and plutonium isotopes in environmental samples by extraction chromatography using sequential injection analysis and ICP-MS
    Qiao, Jixin
    Hou, Xiaolin
    Roos, Per
    Miro, Manuel
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (11) : 1769 - 1779
  • [50] Simultaneous determination of 237Np, 238-240Pu and 241Am in HNO3 solution by combining extraction, liquid scintillation counting, and α spectrometry
    Feng, Xiao-gui
    He, Qian-ge
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3) : 165 - 171