Rapid and Simultaneous Determination of 238Pu, 239Pu, 240Pu, and 241Pu in Samples with High-Level Uranium Using ICP-MS/MS and Extraction Chromatography

被引:6
作者
Huang, Zhao [1 ,3 ]
Hou, Xiaolin [1 ,2 ,5 ]
Zhao, Xue [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Inst Earth Environm, Xian AMS Ctr, Shaanxi Key Lab Accelerator Mass Spectrometry,Stat, Xian 710061, Peoples R China
[2] Pilot Natl Lab Marine Sci & Technol Qingdao, Open Studio Ocean Continental Climate & Environm C, Qingdao 266061, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Xian Inst Innovat Earth Environm Res, Xian 710061, Peoples R China
[5] Tech Univ Denmark, Dept Environm & Resource Engn, DK-4000 Roskilde, Denmark
基金
中国国家自然科学基金;
关键词
PLASMA-MASS SPECTROMETRY; PLUTONIUM ISOTOPES; PU ISOTOPES; ENVIRONMENTAL-SAMPLES; SEDIMENT SAMPLES; SOIL; AM; MS; RADIONUCLIDES; ACTINIDES;
D O I
10.1021/acs.analchem.3c02526
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As the most important plutonium isotopes, Pu-238, Pu-239, Pu-240, and Pu-241 arenormallymeasured by two to three techniques, which are tedious, time-consuming,and not suitable for rapid analysis in emergency situations. Recently,ICP-MS has become a competitive technique for the rapid measurementof Pu-239, Pu-240, and Pu-241. However,ICP-MS is difficult to measure Pu-238 due to the seriousisobaric interference of U-238. This work reports a rapidanalytical method to solve this problem for the simultaneous determinationof Pu-238, Pu-239, Pu-240, and Pu-241 using triple-quadrupole inductively coupled plasma massspectrometry (ICP-MS/MS) combined with chemical separation. Chemicalseparation achieved a high decontamination factor of 2.12 x 10(9) for the most critical interfering element, uranium, by usingtwo sequential TK200 columns. The interferences of (UH+)-U-238-H-1 and U-238(+) were effectivelyeliminated by using 12 mL/min He-6 mL/min NH3 asthe reaction gases in the octupole collision/reaction cell in ICP-MS/MS.Combined with chemical separation, the overall elimination efficiencyof (UH+)-U-238-H-1 reached 3.6 x 10(17), which is 10(5) times better than the reportedmethod. With the high U-238(+) elimination efficiencyof 1.12 x 10(4) in the ICP-MS/MS measurement, the overallremoval efficiency of U-238(+) reached 10(13), guaranteeing accurate determination of femtogram-level Pu-238 as well as Pu-239, Pu-240, and Pu-241 in the samples containing milligram-level U-238. Thedetection time is reduced to minutes, well fulfilling the requirementof rapid analysis. This method is validated by analyzing the standardreference material and the spiked samples.
引用
收藏
页码:12931 / 12939
页数:9
相关论文
共 50 条
  • [31] Origin and age of an ongoing radioactive contamination of soils near La hague reprocessing plant based on 239+240Pu/238Pu and 241Am/241Pu current ratios and 90Sr and Ln(III) soil contents
    Pittet, Pierre-Andre
    Josset, Mylene
    Boilley, David
    Bernollin, Antoine
    Rougier, Guillaume
    Froidevaux, Pascal
    CHEMOSPHERE, 2021, 270
  • [32] Distribution and flux of 238Pu, 239,240Pu, 241Am, 137Cs and 210Pb to high arctic lakes in the Thule district (Greenland)
    Eriksson, M
    Holm, E
    Roos, P
    Dahlgaard, H
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2004, 75 (03) : 285 - 299
  • [33] Radionuclides of iron (55Fe), nickel (63Ni), polonium (210Po), uranium (234U, 235U, 238U) and plutonium (238Pu, 239+240Pu, 241Pu) in Poland and Baltic Sea environment
    Skwarzec, Bogdan
    struminska, Dagmara I.
    Borylo, Alicja
    NUKLEONIKA, 2006, 51 : S45 - S51
  • [34] Application of new covalently-bound diglycolamide sorbent in sequential injection analysis flow system for sample pretreatment in ICP-MS determination of 239Pu at ppt level
    Kolacinska, Kamila
    DeVol, Timothy A.
    Seliman, Ayman F.
    Bliznyuk, Valery N.
    Dudek, Jakub
    Dudek, Marta K.
    Piotrowski, Piotr
    Trojanowicz, Marek
    TALANTA, 2019, 205
  • [35] Assessing Gas-Phase Ion Reactivity of 50 Elements with NO and the Direct Application for 239Pu in Complex Matrices Using ICP-MS/MS
    Hobbs, Kirby P.
    French, Amanda D.
    Melby, Kali M.
    Bylaska, Eric J.
    Harouaka, Khadouja
    Cox, Richard M.
    Arnquist, Isaac J.
    Beck, Chelsie L.
    ANALYTICAL CHEMISTRY, 2024, 96 (15) : 5807 - 5814
  • [36] A record of 241Am, 236U, 238U, 239Pu, 240Pu, 134Cs and 137Cs in surface seawater and 241Am in aerosols shortly after the FDNPP incident occurred
    Shinonaga, Taeko
    Gueckel, Katharina
    Yamada, Masatoshi
    Gamo, Toshitaka
    Steier, Peter
    Christl, Marcus
    Wang, Zhongtang
    Czeslik, Uta
    Tazoe, Hirofumi
    Tschiersch, Jochen
    GEOCHEMICAL JOURNAL, 2021, 55 (01) : 33 - 38
  • [37] Determination of 237Np and 239Pu in urine using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS)
    Xiao, Ge
    Liu, Yongzhong
    Jones, Robert L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 324 (02) : 887 - 896
  • [38] Determination of 239Pu and 240Pu isotope ratio for a nuclear bomb particle using X-ray spectrometry in conjunction with γ-ray spectrometry and non-destructive α-particle spectrometry
    Pollanen, R.
    Ruotsalainen, K.
    Toivonen, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (02) : 515 - 521
  • [39] A rapid method for quantifying 238Pu in the presence of natural 238U via quadrupole inductively coupled plasma mass spectrometry (ICP-MS) and utilizing a resin-based extraction procedure
    Tiong, Ling Ying Diane
    Ho, Mer Lin Doris
    Pong, Boon Kin
    Webster, Richard D.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 314 (02) : 1347 - 1351
  • [40] Improved radioanalytical method for the simultaneous determination of Th, U, Np, Pu and Am(Cm) on a single TRU column by alpha spectrometry and ICP-MS
    Macsik, Z.
    Groska, J.
    Vajda, N.
    Vogt, S.
    Kis-Benedek, G.
    Kim, C. S.
    Maddison, A.
    Donohue, D.
    RADIOCHIMICA ACTA, 2013, 101 (04) : 241 - 251