Numerical Optimization of Battery Heat Management of Electric Vehicles

被引:6
作者
Szurke, Szabolcs Kocsis [1 ]
Kovacs, Gabor [1 ]
Sysyn, Mykola [2 ]
Liu, Jianxing [3 ]
Fischer, Szabolcs [1 ]
机构
[1] Szechenyi Istvan Univ, Cent Campus Gyor, H-9026 Gyor, Hungary
[2] Tech Univ Dresden, Inst Railway Syst & Publ Transport, Dept Planning & Design Railway Infrastructure, D-01069 Dresden, Germany
[3] Southwest Jiaotong Univ, Sch Civil Engn, Chengdu 610031, Peoples R China
来源
JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS | 2023年 / 9卷 / 04期
关键词
Lithium-ion battery; thermal management; CFD simulation; battery test; thermal modeling; THERMAL MANAGEMENT; ION BATTERIES;
D O I
10.22055/jacm.2023.43703.4119
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Lithium-ion battery technology in the modern automotive industry utilizes highly temperature-sensitive batteries. Here, air cooling strategies will be the most applicable for the chosen example based on strategies for temperature control. Simulations have been utilized to evaluate the different thermal management strategies. A battery model was developed using the solutions offered by Computational Fluid Dynamics (CFD) simulation technology. It utilizes the heat produced by the discharge of the battery cells. Due to the simulation's limited computational capacity, the energy transfer model was implemented with a simplified but sufficiently complex physical mesh. Ten actual measurements were conducted in the laboratory to investigate the heating of the cell during the charging and discharging of 18650-type batteries. The results were applied to validate the simulation model. The simulation outcomes and thermal camera readings were compared. The cell-level numerical model was then extended to examine the temperature variation at the system level. The primary design objective is to achieve the highest energy density possible, which necessitates that the cells be constructed as closely as possible; however, increasing the distance between the cells can provide superior cooling from a thermal management perspective. The effect of varying the distance between individual cells on the system's heating was analyzed. Greater distance resulted in a more efficient heat transfer. It was also discovered that, in some instances, a small distance between cells produces inferior results compared to when constructed adjacently. A critical distance range has been established based on these simulations, which facilitates the placement of the cells.
引用
收藏
页码:1076 / 1092
页数:17
相关论文
共 29 条
  • [1] [Anonymous], 2013, ANSYS Meshing User's Guide
  • [2] [Anonymous], CFD MODELING BATTERY
  • [3] [Anonymous], 2020, Thermal Resistance Thermal Conductance - C-Therm Technologies Ltd
  • [4] ANSYS, 2021, Ansys fluent theory guide. 2021 R1. ANSYS I, R1. USA. U.S.A
  • [5] Battery Thermal Management Systems: Current Status and Design Approach of Cooling Technologies
    Buidin, Thomas Imre Cyrille
    Mariasiu, Florin
    [J]. ENERGIES, 2021, 14 (16)
  • [6] Li-ion batteries: basics, progress, and challenges
    Deng, Da
    [J]. ENERGY SCIENCE & ENGINEERING, 2015, 3 (05): : 385 - 418
  • [7] Fischer S., 2015, ACTA TECHNICA JAURIN, V8, P240
  • [8] DETECTION PROCESS OF ENERGY LOSS IN ELECTRIC RAILWAY VEHICLES
    Fischer, Szabolcs
    Szurke, Szabolcs Kocsis
    [J]. FACTA UNIVERSITATIS-SERIES MECHANICAL ENGINEERING, 2023, 21 (01) : 81 - 99
  • [9] Thermal Runaway Modelling of Li-Ion Cells at Various States of Ageing with a Semi-Empirical Model Based on a Kinetic Equation
    Grandjacques, Mathilde
    Kuntz, Pierre
    Azais, Philippe
    Genies, Sylvie
    Raccurt, Olivier
    [J]. BATTERIES-BASEL, 2021, 7 (04):
  • [10] Critical review towards thermal management systems of lithium-ion batteries in electric vehicle with its electronic control unit and assessment tools
    Kannan, C.
    Vignesh, R.
    Karthick, C.
    Ashok, B.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2021, 235 (07) : 1783 - 1807