Midfacial Soft Tissue Recession Following Immediate Implant Placement with Bone Grafting in the Esthetic Area: A Systematic Review and Meta-analysis

被引:7
作者
Wu, Xin-Yu [1 ,2 ,3 ,4 ,5 ]
Shi, Jun-Yu [1 ,2 ,3 ,4 ,5 ]
Yan, Qi [6 ,7 ,8 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Oral & Maxillofacial Implantol, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Coll Stomatol, Shanghai, Peoples R China
[3] Natl Ctr Stomatol, Shanghai, Peoples R China
[4] Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[5] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[6] Wuhan Univ, State Key Lab Breeding Base Basic Sci Stomatol, Wuhan, Peoples R China
[7] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, Minist Educ,Hubei MOST KLOS & KLOBM, Wuhan, Peoples R China
[8] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 237th Luoyu Rd, Wuhan, Peoples R China
关键词
immediate implant placement; midfacial soft tissue recession; systematic review; Shanghai; China; SINGLE-TOOTH IMPLANTS; FRESH EXTRACTION SOCKETS; ANTERIOR MAXILLA; DENTAL IMPLANTS; BUCCAL BONE; PROVISIONALIZATION; FLAPLESS; ZONE; THICKNESS; RESTORATION;
D O I
10.11607/jomi.10014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To systematically analyze the outcomes of immediate implant placement (IIP) with bone grafting in the esthetic area. Materials and Methods: PubMed, Embase, and Cochrane CENTRAL were searched. Prospective studies reporting midfacial soft tissue recession (primary outcome) of single-tooth IIP with bone grafting in the esthetic area were included. Risks of bias were assessed. Meta-analysis, sensitivity analysis, and meta-regression were undertaken. Results: A total of 13 studies and 421 patients were included, with a follow-up length of 1 to 10 years in function. The weighted mean (95% CI) of midfacial soft tissue recession was 0.33 (0.21, 0.46) mm and 0.54 (0.16, 0.93) mm after 1 year and 5 years in function. Meta-regression indicated that after 1 year in function, there was 0.33 mm less midfacial soft tissue recession with soft tissue grafting (P = .021), while there was 0.58 mm more soft tissue recession (P = .007) in defect extraction sockets. Implant survival was 97.8%, and all failures were early failures. Peri-implant soft and hard tissue stability, peri-implant health, esthetic outcomes, and patient satisfaction were predictable within the follow-up period. Conclusion: Midfacial soft tissue recession showed an ongoing status in IIP with bone grafting in the esthetic area within 5 years in function. For extraction sockets with a thin gingival biotype or deficient buccal bone wall, soft tissue grafting was recommended. Int J Oral Maxillofac Implants 2023;38:239-250. doi: 10.11607/jomi.10014
引用
收藏
页码:239 / +
页数:14
相关论文
共 60 条
[1]  
[Anonymous], 2011, BMJ, V343, pd5928, DOI DOI 10.1136/BMJ.D5928
[2]   Tissue modeling following implant placement in fresh extraction sockets [J].
Araujo, Mauricio G. ;
Sukekava, Flavia ;
Wennstroem, Jan L. ;
Lindhe, Jan .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (06) :615-624
[3]   Modeling of the buccal and lingual bone walls of fresh extraction sites following implant installation [J].
Araujo, Mauricio G. ;
Wennstroem, Jan L. ;
Lindhe, Jan .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (06) :606-614
[4]   Ridge alterations following implant placement in fresh extraction sockets:: an experimental study in the dog [J].
Araújo, MG ;
Sukekava, F ;
Wennström, JL ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (06) :645-652
[5]   Immediate and early implant placement in single-tooth gaps in the anterior maxilla: A prospective study on ridge dimensional, clinical, and aesthetic changes [J].
Arora, Himanshu ;
Ivanovski, Saso .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (11) :1143-1154
[6]   Immediate implant placement and restoration in the anterior maxilla: Tissue dimensional changes after 2-5 year follow up [J].
Arora, Himanshu ;
Khzam, Nabil ;
Roberts, David ;
Bruce, William L. ;
Ivanovski, Saso .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (04) :694-702
[7]  
Belser UC, 2009, J PERIODONTOL, V80, P140, DOI [10.1902/jop.2009.080435, 10.1902/jop.2009.080435 ]
[8]  
Bittner N, 2019, INT J ORAL IMPL, V12, P469
[9]   Implant placement in fresh extraction sockets [J].
Blanco, Juan ;
Carral, Cristina ;
Argibay, Olalla ;
Linares, Antonio .
PERIODONTOLOGY 2000, 2019, 79 (01) :151-167
[10]  
Braut V, 2011, INT J PERIODONT REST, V31, P125