Image quality improvement of a one-step spectral CT reconstruction on a prototype photon-counting scanner

被引:2
作者
Rodesch, Pierre-Antoine [1 ]
Si-Mohamed, Salim A. [1 ,2 ]
Lesaint, Jerome [1 ]
Douek, Philippe C. [1 ,2 ]
Rit, Simon [1 ]
机构
[1] Univ Lyon, INSA Lyon, UJM St Etienne, CNRS,Inserm,CREATIS UMR5220,U1294,UCBLyon 1, F-69373 Lyon, France
[2] Louis Pradel Hosp, Dept Radiol, Hosp Civils Lyon, Bron, France
基金
欧盟地平线“2020”;
关键词
computed tomography; spectral CT; photon-counting detector; material decomposition; image quality; one-step; COMPUTED-TOMOGRAPHY; NOISE-REDUCTION; ALGORITHM; DECOMPOSITION; PERFORMANCE; SOCIETY;
D O I
10.1088/1361-6560/ad11a3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. X-ray spectral computed tomography (CT) allows for material decomposition (MD). This study compared a one-step material decomposition MD algorithm with a two-step reconstruction MD algorithm using acquisitions of a prototype CT scanner with a photon-counting detector (PCD). Approach. MD and CT reconstruction may be done in two successive steps, i.e. decompose the data in material sinograms which are then reconstructed in material CT images, or jointly in a one-step algorithm. The one-step algorithm reconstructed material CT images by maximizing their Poisson log-likelihood in the projection domain with a spatial regularization in the image domain. The two-step algorithm maximized first the Poisson log-likelihood without regularization to decompose the data in material sinograms. These sinograms were then reconstructed into material CT images by least squares minimization, with the same spatial regularization as the one step algorithm. A phantom simulating the CT angiography clinical task was scanned and the data used to measure noise and spatial resolution properties. Low dose carotid CT angiographies of 4 patients were also reconstructed with both algorithms and analyzed by a radiologist. The image quality and diagnostic clinical task were evaluated with a clinical score. Main results. The phantom data processing demonstrated that the one-step algorithm had a better spatial resolution at the same noise level or a decreased noise value at matching spatial resolution. Regularization parameters leading to a fair comparison were selected for the patient data reconstruction. On the patient images, the one-step images received higher scores compared to the two-step algorithm for image quality and diagnostic. Significance. Both phantom and patient data demonstrated how a one-step algorithm improves spectral CT image quality over the implemented two-step algorithm but requires a longer computation time. At a low radiation dose, the one-step algorithm presented good to excellent clinical scores for all the spectral CT images.
引用
收藏
页数:14
相关论文
共 50 条
[31]   Ultrahigh-Resolution Photon-Counting Detector CT of the Lungs: Association of Reconstruction Kernel and Slice Thickness With Image Quality [J].
Milos, Ruxandra-Iulia ;
Roehrich, Sebastian ;
Prayer, Florian ;
Strassl, Andreas ;
Beer, Lucian ;
Heidinger, Benedikt H. ;
Weber, Michael ;
Watzenboeck, Martin L. ;
Kifjak, Daria ;
Tamandl, Dietmar ;
Prosch, Helmut .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (05) :672-680
[32]   Principal Component Analysis in Projection and Image Domains-Another Form of Spectral Imaging in Photon-Counting CT [J].
Xie, Huiqiao ;
Ren, Yan ;
Long, Wenting ;
Yang, Xiaofeng ;
Tang, Xiangyang .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (03) :1074-1083
[33]   Soft Reconstruction Kernels Improve HCC Imaging on a Photon-Counting Detector CT [J].
Graafen, D. ;
Mueller, L. ;
Halfmann, M. C. ;
Stoehr, F. ;
Foerster, F. ;
Dueber, C. ;
Yang, Y. ;
Kloeckner, R. ;
Emrich, T. .
ACADEMIC RADIOLOGY, 2023, 30 :S143-S154
[34]   Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment [J].
Pourmorteza, A. ;
Symons, R. ;
Reich, D. S. ;
Bagheri, M. ;
Cork, T. E. ;
Kappler, S. ;
Ulzheimer, S. ;
Bluemke, D. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (12) :2257-2263
[35]   Voxelwise characterization of noise for a clinical photon-counting CT scanner with a model-based iterative reconstruction algorithm [J].
Masturzo, Luigi ;
Barca, Patrizio ;
De Masi, Luca ;
Marfisi, Daniela ;
Traino, Antonio ;
Cademartiri, Filippo ;
Giannelli, Marco .
EUROPEAN RADIOLOGY EXPERIMENTAL, 2025, 9 (01)
[36]   Photon counting CT: Effects of dynamic beam attenuator on image quality [J].
Atak, Haluk ;
Shikhaliev, Polad M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 867 :58-71
[37]   A Spectral CT Method to Directly Estimate Basis Material Maps From Experimental Photon-Counting Data [J].
Schmidt, Taly Gilat ;
Barber, Rina Foygel ;
Sidky, Emil Y. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (09) :1808-1819
[38]   Comparison of spectral CT imaging methods based a photon-counting detector: Experimental study [J].
Lee, Youngjin ;
Lee, Seungwan ;
Kim, Hee-Joung .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 815 :68-74
[39]   Spectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen [J].
Bjorkman, Ann-Sofi ;
Malusek, Alexandr ;
Gauffin, Hakan ;
Persson, Anders ;
Koskinen, Seppo K. .
EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
[40]   Application of machine-learning models to improve the image quality of photon-counting CT images [J].
Toyoda, T. ;
Sato, S. ;
Kiji, H. ;
Kataoka, J. ;
Kotoku, J. ;
Taki, M. .
JOURNAL OF INSTRUMENTATION, 2021, 16 (05)