Image quality improvement of a one-step spectral CT reconstruction on a prototype photon-counting scanner

被引:2
作者
Rodesch, Pierre-Antoine [1 ]
Si-Mohamed, Salim A. [1 ,2 ]
Lesaint, Jerome [1 ]
Douek, Philippe C. [1 ,2 ]
Rit, Simon [1 ]
机构
[1] Univ Lyon, INSA Lyon, UJM St Etienne, CNRS,Inserm,CREATIS UMR5220,U1294,UCBLyon 1, F-69373 Lyon, France
[2] Louis Pradel Hosp, Dept Radiol, Hosp Civils Lyon, Bron, France
基金
欧盟地平线“2020”;
关键词
computed tomography; spectral CT; photon-counting detector; material decomposition; image quality; one-step; COMPUTED-TOMOGRAPHY; NOISE-REDUCTION; ALGORITHM; DECOMPOSITION; PERFORMANCE; SOCIETY;
D O I
10.1088/1361-6560/ad11a3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. X-ray spectral computed tomography (CT) allows for material decomposition (MD). This study compared a one-step material decomposition MD algorithm with a two-step reconstruction MD algorithm using acquisitions of a prototype CT scanner with a photon-counting detector (PCD). Approach. MD and CT reconstruction may be done in two successive steps, i.e. decompose the data in material sinograms which are then reconstructed in material CT images, or jointly in a one-step algorithm. The one-step algorithm reconstructed material CT images by maximizing their Poisson log-likelihood in the projection domain with a spatial regularization in the image domain. The two-step algorithm maximized first the Poisson log-likelihood without regularization to decompose the data in material sinograms. These sinograms were then reconstructed into material CT images by least squares minimization, with the same spatial regularization as the one step algorithm. A phantom simulating the CT angiography clinical task was scanned and the data used to measure noise and spatial resolution properties. Low dose carotid CT angiographies of 4 patients were also reconstructed with both algorithms and analyzed by a radiologist. The image quality and diagnostic clinical task were evaluated with a clinical score. Main results. The phantom data processing demonstrated that the one-step algorithm had a better spatial resolution at the same noise level or a decreased noise value at matching spatial resolution. Regularization parameters leading to a fair comparison were selected for the patient data reconstruction. On the patient images, the one-step images received higher scores compared to the two-step algorithm for image quality and diagnostic. Significance. Both phantom and patient data demonstrated how a one-step algorithm improves spectral CT image quality over the implemented two-step algorithm but requires a longer computation time. At a low radiation dose, the one-step algorithm presented good to excellent clinical scores for all the spectral CT images.
引用
收藏
页数:14
相关论文
共 50 条
[21]   Evaluation of a preclinical photon-counting CT prototype for pulmonary imaging [J].
Kopp, Felix K. ;
Daerr, Heiner ;
Si-Mohamed, Salim ;
Sauter, Andreas P. ;
Ehn, Sebastian ;
Fingerle, Alexander A. ;
Brendel, Bernhard ;
Pfeiffer, Franz ;
Roessl, Ewald ;
Rummeny, Ernst J. ;
Pfeiffer, Daniela ;
Proksa, Roland ;
Douek, Philippe ;
Noel, Peter B. .
SCIENTIFIC REPORTS, 2018, 8
[22]   Increased separability of K-edge nanoparticles by photon-counting detectors for spectral micro-CT [J].
Getzin, Matthew ;
Garfield, Josephine J. ;
Rundle, David S. ;
Kruger, Uwe ;
Butler, Anthony P. H. ;
Gkikas, Manos ;
Wang, Ge .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (05) :707-726
[23]   Quantum iterative reconstruction on a photon-counting detector CT improves the quality of hepatocellular carcinoma imaging [J].
Graafen, Dirk ;
Stoehr, Fabian ;
Halfmann, Moritz C. C. ;
Emrich, Tilman ;
Foerster, Friedrich ;
Yang, Yang ;
Dueber, Christoph ;
Mueller, Lukas ;
Kloeckner, Roman .
CANCER IMAGING, 2023, 23 (01)
[24]   Spectral Photon-Counting CT Technology in Chest Imaging [J].
Si-Mohamed, Salim Aymeric ;
Miailhes, Jade ;
Rodesch, Pierre-Antoine ;
Boccalini, Sara ;
Lacombe, Hugo ;
Leitman, Valerie ;
Cottin, Vincent ;
Boussel, Loic ;
Douek, Philippe .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
[25]   One-Step Material Decomposition for Photon-Counting CT Using Implicit Neural Representation and Physics-Guided Model [J].
Qin, Wenhui ;
Yu, Xiaopeng ;
Liu, Zhentao ;
Zhong, Tao ;
Zhang, Yikun ;
Ji, Xu ;
Wang, Wenying ;
Cui, Zhiming ;
Quan, Guatao ;
Chen, Yang ;
Lai, Xiaochun .
MEDICAL IMAGING 2025: PHYSICS OF MEDICAL IMAGING, PT 1, 2025, 13405
[26]   Image quality of photon-counting detector CT virtual monoenergetic and polyenergetic reconstructions for head and neck CT angiography [J].
Spampinato, Maria Vittoria ;
Rodgers, Jeffrey ;
McGill, Liam J. ;
Schoepf, Uwe Joseph ;
O'Doherty, Jim .
CLINICAL IMAGING, 2024, 108
[27]   Photon-counting spectral CT reconstruction with sparse and double low-rank components fusion [J].
Yang, Zhaojun ;
Zeng, Li ;
Wang, Zhe ;
Xu, Qiong ;
Gong, ChangCheng ;
Shen, Zhaoqiang ;
He, Yuanwei ;
Niu, Xiaoming ;
Chen, Wei .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 86
[28]   Photon-counting CT: modeling and compensating of spectral distortion effects [J].
Cammin, Jochen ;
Kappler, Steffen ;
Weidinger, Thomas ;
Taguchi, Katsuyuki .
MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
[29]   Image-based spectral distortion correction for photon-counting x-ray detectors [J].
Ding, Huanjun ;
Molloi, Sabee .
MEDICAL PHYSICS, 2012, 39 (04) :1864-1876
[30]   Calibration methods influence quantitative material decomposition in photon-counting spectral CT [J].
Curtis, Tyler E. ;
Roeder, Ryan K. .
MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132