A novel non-contact heart rate measurement method based on EEMD combined with FastICA

被引:9
作者
Shi, Yingli [1 ,2 ]
Qiu, Jian [1 ,2 ]
Peng, Li [1 ,2 ]
Han, Peng [1 ,2 ]
Luo, Kaiqing [1 ,2 ]
Liu, Dongmei [1 ,2 ]
机构
[1] South China Normal Univ, Sch Phys & Telecommun Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] South China Normal Univ, Qingyuan Inst Sci & Technol Innovat, Qingyuan 511517, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
imaging photoplethysmography (IPPG); modified EEMD; modified FastICA; heart rate (HR); multi-region ROI; EMPIRICAL MODE DECOMPOSITION; IMAGE SENSOR; ROBUST;
D O I
10.1088/1361-6579/accefd
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. The imaging photoplethysmography (IPPG), which is applied to heart rate measurement, is susceptible to interference caused by illumination variations during photography. To improve the accuracy, robustness, and real-time performance of IPPG, a new method combined with modified ensemble empirical mode decomposition (EEMD) and fast independent component analysis (FastICA) was proposed. Approach. On the modified EEMD, to reduce the error caused by the residual white noise of the algorithm, it was characterized by recurrently updating zero-mean white noise for ensemble averaging based on the standard deviation of the input signal. On the modified FastICA, its constructed nonlinear function was superseded by Huber's approximation function to improve the robustness and running speed. Main results. Comparison experiments were conducted between the MAHNOB-HCI database and own collected data. In the hybrid natural light and computer screen light scenario, the mean absolute error (MAE) of heart rate amounted to 0.93 beats per minute and the correlation coefficient r
引用
收藏
页数:15
相关论文
共 35 条
[11]  
Hyvarinen A, 1998, ADV NEUR IN, V10, P273
[12]   One-unit contrast functions for independent component analysis: A statistical analysis [J].
Hyvarinen, A .
NEURAL NETWORKS FOR SIGNAL PROCESSING VII, 1997, :388-397
[13]   A systematic review of novel technology for monitoring infant and newborn heart rate [J].
Kevat, Ajay C. ;
Bullen, Denise V. R. ;
Davis, Peter G. ;
Kamlin, C. Omar F. .
ACTA PAEDIATRICA, 2017, 106 (05) :710-720
[14]   A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion Artifacts [J].
Khan, Emroz ;
Al Hossain, Forsad ;
Uddin, Shiekh Zia ;
Alam, S. Kaisar ;
Hasan, Md. Kamrul .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (03) :550-562
[15]   Assessment of ROI Selection for Facial Video-Based rPPG [J].
Kim, Dae-Yeol ;
Lee, Kwangkee ;
Sohn, Chae-Bong .
SENSORS, 2021, 21 (23)
[16]   Robust Heart Rate Measurement from Video Using Select Random Patches [J].
Lam, Antony ;
Kuno, Yoshinori .
2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2015, :3640-3648
[17]   A deep learning approach to estimate pulse rate by remote photoplethysmography [J].
Lampier, Lucas Cogo ;
Valadao, Carlos Torturella ;
Silva, Leticia Araujo ;
Delisle-Rodriguez, Denis ;
de Oliveira Caldeira, Eliete Maria ;
Bastos-Filho, Teodiano Freire .
PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
[18]  
Lewandowska M., 2011, 2011 Federated Conference on Computer Science and Information Systems (FedCSIS), P405
[19]   Remote Heart Rate Measurement From Face Videos Under Realistic Situations [J].
Li, Xiaobai ;
Chen, Jie ;
Zhao, Guoying ;
Pietikainen, Matti .
2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, :4264-4271
[20]   Remote Measurement of Short-Term Heart Rate With Narrow Beam Millimeter Wave Radar [J].
Lv, Wenjie ;
Zhao, Yan ;
Zhang, Wei ;
Liu, Wenqi ;
Hu, Anyong ;
Miao, Jungang .
IEEE ACCESS, 2021, 9 :165049-165058