A novel non-contact heart rate measurement method based on EEMD combined with FastICA

被引:10
作者
Shi, Yingli [1 ,2 ]
Qiu, Jian [1 ,2 ]
Peng, Li [1 ,2 ]
Han, Peng [1 ,2 ]
Luo, Kaiqing [1 ,2 ]
Liu, Dongmei [1 ,2 ]
机构
[1] South China Normal Univ, Sch Phys & Telecommun Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] South China Normal Univ, Qingyuan Inst Sci & Technol Innovat, Qingyuan 511517, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
imaging photoplethysmography (IPPG); modified EEMD; modified FastICA; heart rate (HR); multi-region ROI; EMPIRICAL MODE DECOMPOSITION; IMAGE SENSOR; ROBUST;
D O I
10.1088/1361-6579/accefd
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. The imaging photoplethysmography (IPPG), which is applied to heart rate measurement, is susceptible to interference caused by illumination variations during photography. To improve the accuracy, robustness, and real-time performance of IPPG, a new method combined with modified ensemble empirical mode decomposition (EEMD) and fast independent component analysis (FastICA) was proposed. Approach. On the modified EEMD, to reduce the error caused by the residual white noise of the algorithm, it was characterized by recurrently updating zero-mean white noise for ensemble averaging based on the standard deviation of the input signal. On the modified FastICA, its constructed nonlinear function was superseded by Huber's approximation function to improve the robustness and running speed. Main results. Comparison experiments were conducted between the MAHNOB-HCI database and own collected data. In the hybrid natural light and computer screen light scenario, the mean absolute error (MAE) of heart rate amounted to 0.93 beats per minute and the correlation coefficient r
引用
收藏
页数:15
相关论文
共 35 条
[1]   Automatic Detection of Driver Impairment Based on Pupillary Light Reflex [J].
Amodio, Alessandro ;
Ermidoro, Michele ;
Maggi, Davide ;
Formentin, Simone ;
Savaresi, Sergio Matteo .
IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2019, 20 (08) :3038-3048
[2]   Combining Chrominance Features and Fast ICA for Noncontact Imaging Photoplethysmography [J].
Cai, Ken ;
Yue, Hongwei ;
Li, Bohan ;
Chen, Weitong ;
Huang, Wenhua .
IEEE ACCESS, 2020, 8 :50171-50179
[3]  
Casado CA, 2022, Arxiv, DOI arXiv:2202.04101
[4]   Image Sensor-Based Heart Rate Evaluation From Face Reflectance Using Hilbert-Huang Transform [J].
Chen, Duan-Yu ;
Wang, Jun-Jhe ;
Lin, Kuan-Yi ;
Chang, Hen-Hong ;
Wu, Han-Kuei ;
Chen, Yung-Sheng ;
Lee, Suh-Yin .
IEEE SENSORS JOURNAL, 2015, 15 (01) :618-627
[5]   Remote Heart Rate Measurement From Near-Infrared Videos Based on Joint Blind Source Separation With Delay-Coordinate Transformation [J].
Cheng, Juan ;
Wang, Ping ;
Song, Rencheng ;
Liu, Yu ;
Li, Chang ;
Liu, Yong ;
Chen, Xun .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70 (70)
[6]   Robust Pulse Rate From Chrominance-Based rPPG [J].
de Haan, Gerard ;
Jeanne, Vincent .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) :2878-2886
[7]   Simple, robust, and memory-efficient FastICA algorithms using the huber m-estimator cost function [J].
Douglas, Scott C. ;
Chao, Jih Cheng .
JOURNAL OF VLSI SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2007, 48 (1-2) :143-159
[8]   Real-Time Webcam Heart-Rate and Variability Estimation with Clean Ground Truth for Evaluation † [J].
Gudi, Amogh ;
Bittner, Marian ;
van Gemert, Jan .
APPLIED SCIENCES-BASEL, 2020, 10 (23) :1-24
[9]   The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis [J].
Huang, NE ;
Shen, Z ;
Long, SR ;
Wu, MLC ;
Shih, HH ;
Zheng, QN ;
Yen, NC ;
Tung, CC ;
Liu, HH .
PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1998, 454 (1971) :903-995
[10]   A fast fixed-point algorithm for independent component analysis [J].
Hyvarinen, A ;
Oja, E .
NEURAL COMPUTATION, 1997, 9 (07) :1483-1492