Seismic behaviour of Exterior RC beam-column joints repaired and strengthened using post-tensioned metal straps

被引:10
作者
Helal, Yasser [1 ]
Garcia, Reyes [2 ]
Imjai, Thanongsak [3 ]
Aosai, Pakjira [3 ]
Guadagnini, Maurizio [4 ]
Pilakoutas, Kypros [4 ]
机构
[1] AECOM Ltd, Manchester, England
[2] Univ Warwick, Sch Engn, Civil Engn Stream, Coventry CV4 7AL, England
[3] Walailak Univ, Ctr Excellence Sustainable Disaster Management, Sch Engn & Technol, Nakhonsithammarat 80161, Thailand
[4] Univ Sheffield, Dept Civil & Struct Engn, Sheffield S1 3JD, England
关键词
Beam-column joints; Reinforced concrete; Seismic strengthening; Concrete repairs; Post-tensioned metal straps; Numerical modelling; RISK-ASSESSMENT; CONCRETE; REHABILITATION; PERFORMANCE; CFRP; RETROFIT; DESIGN;
D O I
10.1007/s10518-024-01904-1
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Exterior beam-column joints are the most vulnerable part of substandard reinforced concrete (RC) buildings and are often the first to be damaged during earthquakes. This article presents an experimental and numerical investigation into the behaviour of exterior RC beam-column joints repaired and strengthened using Post-Tensioned Metal Straps (PTMS) for active confinement. The study focused on full-scale beam-column joints with an inadequate core zone detailing, thus emulating the deficiencies found in existing substandard RC buildings. Initially, four "bare" joints were subjected to cyclic tests to induce substantial damage within the core zone. Subsequently, the damaged core of the joints was repaired and recast with new concrete, and PTMS were applied to strengthen the joints, followed by another round of cyclic testing. The experimental findings were compared with predictions generated through established models from existing literature. The results revealed that ASCE/SEI 41-17 guidelines accurately predict the shear capacity of the bare joints. It is shown that recasting the core with new concrete significantly increased the joint's shear capacity by up to 42% compared their bare counterparts. The use of PTMS strengthening further enhanced the capacity by up to 25%. A "scissors model" was employed for numerical simulations of both bare and PTMS-strengthened joints using DRAIN-2DX, which proved effective at predicting their nonlinear load-displacement envelope response. This article contributes towards the development of new cost-effective post-earthquake strengthening techniques for beam-column joints, with the potential to reduce the vulnerability of substandard RC buildings in developing countries.
引用
收藏
页码:3261 / 3286
页数:26
相关论文
共 65 条
[1]   Shear strengthening of normal steel reinforced concrete beams using post-tensioned metal straps fully wrapped around the beams [J].
Abdullah, Wrya .
ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (09) :1636-1646
[2]   Evaluating the ductility reduction factors of SDOF self-centering earthquake-resisting structural systems [J].
Abou-Elfath, Hamdy ;
Ramadan, Mostafa ;
Elhout, Emad .
BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (03) :1605-1624
[3]   Fatigue performance of flexible steel fibre reinforced rubberised concrete pavements [J].
Alsaif, Abdulaziz ;
Garcia, Reyes ;
Figueiredo, Fabio P. ;
Neocleous, Kyriacos ;
Christofe, Andreas ;
Guadagnini, Maurizio ;
Pilakoutas, Kypros .
ENGINEERING STRUCTURES, 2019, 193 :170-183
[4]   Suitable intensity measure for probabilistic seismic risk assessment of non-ductile Australian reinforced concrete buildings [J].
Amirsardari, Anita ;
Rajeev, Pathmanathan ;
Lumantarna, Elisa ;
Goldsworthy, Helen M. .
BULLETIN OF EARTHQUAKE ENGINEERING, 2019, 17 (07) :3753-3775
[5]  
[Anonymous], 2017, ASCE/SEI 41-17)
[6]  
[Anonymous], 2009, BSI BS EN 12390-3
[7]  
[Anonymous], 2009, BSI BS EN 12390-6
[8]   Strengthening and rehabilitation of exterior RC beam-column joints using carbon-FRP jacketing [J].
Beydokhti, Ebrahim Zamani ;
Shariatmadar, Hashem .
MATERIALS AND STRUCTURES, 2016, 49 (12) :5067-5083
[9]  
Bindhu K., 2010, Asian Journal of Civil Engineering (Building and Housing), V11, P397
[10]   New Reinforcement Detailing for Concrete Jacketing of Nonductile Exterior Beam-Column Joints [J].
Bindhu, K. R. ;
Mohana, N. ;
Sivakumar, S. .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2016, 30 (01)