Optic nerve sheath diameter measurements to predict delayed neurological sequelae after carbon monoxide poisoning

被引:0
作者
Tekin, Yusuf Kenan [1 ,2 ]
机构
[1] Sivas Cumhuriyet Univ, Dept Emergency Med, Sivas, Turkiye
[2] Sivas Cumhuriyet Univ, Fac Med, Dept Emergency Med, TR-58140 Sivas, Turkiye
关键词
Carbon monoxide poisoning; delayed neuropsychiatric syndrome; optic nerve sheath diameter; cranial computed tomography; toxicology; MANAGEMENT; NEUROPATHOLOGY; TOMOGRAPHY;
D O I
10.1080/15563650.2024.2323092
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Objectives: Delayed neurological sequelae are a major complication of carbon monoxide poisoning. However, today there is still no objective screening tool for predicting delayed neurological sequelae in patients with carbon monoxide poisoning. The present study aimed to assess the usefulness of optic nerve sheath diameter measurements in predicting delayed neurological sequelae after carbon monoxide poisoning. Methods: In this retrospective study, patients with a diagnosis of carbon monoxide poisoning in the emergency department from 2010 to 2021 were included in the study. Right and left optic nerve sheath diameters were calculated based on cranial computed tomography scans, and the presence of delayed neurological sequelae was evaluated. Results: The mean (+/- standard deviation) optic nerve sheath diameter in patients who developed delayed neurological sequelae was statistically significantly greater on both the right and left compared to patients who did not develop delayed neurological sequelae (right; 5.02 +/- 0.06 mm versus 4.89 +/- 0.07 mm, P < 0.001; left; 5.03 +/- 0.09 mm versus 4.85 +/- 0.10 mm, P < 0.001). A multivariate linear regression analysis revealed that carboxyhemoglobin and both right and left optic nerve sheath diameter were the factors associated with the delayed neurological sequelae. Discussion: The present study revealed that optic nerve sheath diameter measurements may be a useful screening tool to predict delayed neurological sequelae after carbon monoxide poisoning. The ability to predict a poor neurological prognosis in carbon monoxide poisoning is important for initiating early rehabilitation interventions and make help future trials. Limitations of this study include that normal optic nerve sheath diameters are not well established, and that not every patient underwent computed tomography. Conclusions: Optic nerve sheath diameters measurements may be a helpful screening tool for predicting delayed neurological sequelae after carbon monoxide poisoning.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 27 条
[1]   Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure [J].
Amini, Afshin ;
Kariman, Hamid ;
Dolatabadi, Ali Arhami ;
Hatamabadi, Hamid Reza ;
Derakhshanfar, Hojjat ;
Mansouri, Behnam ;
Safari, Saeed ;
Eqtesadi, Razie .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (01) :236-239
[2]   Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging [J].
Baeuerle, Jochen ;
Schuchardt, Florian ;
Schroeder, Laure ;
Egger, Karl ;
Weigel, Matthias ;
Harloff, Andreas .
BMC NEUROLOGY, 2013, 13
[3]  
Betterman Kerstin, 2014, Handb Clin Neurol, V120, P971, DOI 10.1016/B978-0-7020-4087-0.00064-4
[4]   Sulphoraphane Improves Neuronal Mitochondrial Function in Brain Tissue in Acute Carbon Monoxide Poisoning Rats [J].
Bi, Mingjun ;
Li, Qin ;
Guo, Dadong ;
Ding, Xiaoyu ;
Bi, Weikang ;
Zhang, Yueheng ;
Zou, Yong .
BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2017, 120 (06) :541-549
[5]   The optic nerve sheath diameter as a useful tool for early prediction of outcome after cardiac arrest: A prospective pilot study [J].
Chelly, Jonathan ;
Deye, Nicolas ;
Guichard, Jean-Pierre ;
Vodovar, Dominique ;
Ly Vong ;
Jochmans, Sebastien ;
Thieulot-Rolin, Nathalie ;
Sy, Oumar ;
Serbource-Goguel, Jean ;
Vinsonneau, Christophe ;
Megarbane, Bruno ;
Vivien, Benoit ;
Tazarourte, Karim ;
Monchi, Merhan .
RESUSCITATION, 2016, 103 :7-13
[6]   Delayed leukoencephalopathy after acute carbon monoxide intoxication [J].
Geraldo, Ana Filipa ;
Silva, Cristiana ;
Neutel, Dulce ;
Lucas Neto, Lia ;
Albuquerque, Luisa .
JOURNAL OF RADIOLOGY CASE REPORTS, 2014, 8 (05) :1-8
[7]   Utility of optic nerve ultrasonography in head injury [J].
Goel, Ravishankar S. ;
Goyal, Navin K. ;
Dharap, Satish B. ;
Kumar, Meena ;
Gore, Madhuri A. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (05) :519-524
[8]   Practice Recommendations in the Diagnosis, Management, and Prevention of Carbon Monoxide Poisoning [J].
Hampson, Neil B. ;
Piantadosi, Claude A. ;
Thom, Stephen R. ;
Weaver, Lindell K. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2012, 186 (11) :1095-1101
[9]   Bias in the measurement of optic nerve sheath diameter [J].
Hossein-Nejad, Hooman ;
Bahreini, Maryam ;
Rasooli, Fatemeh .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (02) :323-324
[10]   Impact of Hyperbaric Oxygen Therapy on Subsequent Neurological Sequelae Following Carbon Monoxide Poisoning [J].
Huang, Chien-Cheng ;
Ho, Chung-Han ;
Chen, Yi-Chen ;
Hsu, Chien-Chin ;
Wang, Yi-Fong ;
Lin, Hung-Jung ;
Wang, Jhi-Joung ;
Guo, How-Ran .
JOURNAL OF CLINICAL MEDICINE, 2018, 7 (10)