A novel electrochemical biosensor based on palladium nanoparticles decorated on reduced graphene oxide-polyaminophenol matrix for the detection and discrimination of mitomycin C-DNA and acyclovir-DNA interaction

被引:7
|
作者
Yanik, Suzan [1 ]
Emre, Deniz [2 ]
Alp, Meltem [3 ,4 ]
Algi, Fatih [3 ,4 ]
Yilmaz, Selehattin [1 ]
Bilici, Ali [1 ]
Ozkan-Ariksoysal, Dilsat [5 ]
机构
[1] Canakkale Onsekiz Mart Univ, Fac Sci, Dept Chem, Canakkale, Turkiye
[2] Canakkale Onsekiz Mart Univ, Vocat Sch Hlth Serv, Canakkale, Turkiye
[3] Aksaray Univ, Dept Biotechnol, Aksaray, Turkiye
[4] ASUBTAM M Bilmez BioNanoTech Lab, Aksaray, Turkiye
[5] Ege Univ, Fac Pharm, Dept Analyt Chem, Izmir, Turkiye
关键词
Electrochemical DNA nanobiosensor; Drug -DNA interaction; Acyclovir; Mitomycin C; Reduced graphene oxide; palladium; nanoparticles; Voltammetry; POLYANILINE; NANOCOMPOSITES; NANOSHEETS; GUANINE;
D O I
10.1016/j.jpba.2023.115524
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Both the design of molecules that will interact specifically with DNA and the determination of the mechanism of action of this drug on DNA are important as they allow the control of gene expression. In particular, rapid and precise analysis of this type of interaction is a vital element for pharmaceutical studies. In the present study, a novel reduced graphene oxide/ palladium nanoparticles/ poly(2-amino-4-chlorophenol) (rGO/Pd@PACP) nanocomposite was synthesized by chemical process to modify pencil graphite electrode (PGE) surface. Here, the performance of the newly developed nanomaterial-based biosensor for drug-DNA interaction analysis has been demonstrated. For this purpose, it was determined whether this system, which was developed by selecting a drug molecule (Mitomycin C; MC) known to interact with DNA and a drug molecule (Acyclovir; ACY) that does not interact with DNA, performs a reliable/accurate analysis. Here, ACY was used as a negative control. Compared to bare PGE, the rGO/Pd@PACP nanomaterial modified sensor exhibited 17 times higher sensitivity performance in terms of guanine oxidation signal measured by differential pulse voltammetry (DPV). Moreover, the developed nanobiosensor system provided a highly specific determination between the anticancer drug MC and ACY by discrimination the interactions of these drugs with double-stranded DNA (dsDNA). ACY was also preferred in studies for the optimization of the new nanobiosensor developed. ACY was detected in a concentration as low as 0.0513 & mu;M (51.3 nM) (LOD), and limit of quantification (LOQ) was 0.1711 & mu;M with a linear range from 0.1 to 0.5 & mu;M.
引用
收藏
页数:8
相关论文
共 30 条
  • [1] Graphene oxide integrated sensor for electrochemical monitoring of mitomycin C-DNA interaction
    Erdem, Arzum
    Muti, Mihrican
    Papakonstantinou, Pagona
    Canavar, Ece
    Karadeniz, Hakan
    Congur, Gulsah
    Sharma, Surbhi
    ANALYST, 2012, 137 (09) : 2129 - 2135
  • [2] An ultrasensitive supersandwich electrochemical DNA biosensor based on gold nanoparticles decorated reduced graphene oxide
    Wang, Jiao
    Shi, Anqi
    Fang, Xian
    Han, Xiaowei
    Zhang, Yuzhong
    ANALYTICAL BIOCHEMISTRY, 2015, 469 : 71 - 75
  • [3] ELECTROCHEMICAL BIOSENSOR BASED ON MODIFIED REDUCED GRAPHENE OXIDE WITH SILVER NANOPARTICLES FOR DETECTION OF METHYLATED DNA
    Sedlackova, Eliska
    Birgusova, Eliska
    Bytesnikova, Zuzana
    Svec, Pavel
    Richtera, Lukas
    Adam, Vojtech
    11TH INTERNATIONAL CONFERENCE ON NANOMATERIALS - RESEARCH & APPLICATION (NANOCON 2019), 2020, : 391 - 395
  • [4] A novel and sensitive electrochemical DNA biosensor based on Fe@Au nanoparticles decorated graphene oxide
    Yola, Mehmet Lutfi
    Eren, Tanju
    Atar, Necip
    ELECTROCHIMICA ACTA, 2014, 125 : 38 - 47
  • [5] A Reduced Graphene Oxide-based Electrochemical DNA Biosensor for the Detection of Interaction between Cisplatin and DNA based on Guanine and Adenine Oxidation Signals
    Yardim, Yavuz
    Vandeput, Marie
    Celebi, Metin
    Senturk, Zuhre
    Kauffmann, Jean-Michel
    ELECTROANALYSIS, 2017, 29 (05) : 1451 - 1458
  • [6] Reduced graphene oxide nanoribbon immobilized gold nanoparticle based electrochemical DNA biosensor for the detection of Mycobacterium tuberculosis
    Mogha, Navin Kumar
    Sahu, Vikrant
    Sharma, Raj Kishore
    Masram, Dhanraj T.
    JOURNAL OF MATERIALS CHEMISTRY B, 2018, 6 (31) : 5181 - 5187
  • [7] Gold nanoparticles/single-stranded DNA-reduced graphene oxide nanocomposites based electrochemical biosensor for highly sensitive detection of cholesterol
    Shuyao Wu
    Chengquan Sui
    Chong Wang
    Yulu Wang
    Dongqing He
    Ying Sun
    Yu Zhang
    Qingbo Meng
    Tianyi Ma
    XiMing Song
    Frontiers of Chemical Science and Engineering, 2021, 15 (06) : 1572 - 1582
  • [8] Electrochemical DNA biosensor based on gold nanoparticles and partially reduced graphene oxide modified electrode for the detection of Listeria monocytogenes hly gene sequence
    Niu, Xueliang
    Zheng, Wen
    Yin, Chunxiao
    Weng, Wenju
    Li, Guangjiu
    Sun, Wei
    Men, Yongling
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 806 : 116 - 122
  • [9] Gold nanoparticles/single-stranded DNA-reduced graphene oxide nanocomposites based electrochemical biosensor for highly sensitive detection of cholesterol
    Shuyao Wu
    Chengquan Sui
    Chong Wang
    Yulu Wang
    Dongqing He
    Ying Sun
    Yu Zhang
    Qingbo Meng
    Tianyi Ma
    Xi-Ming Song
    Frontiers of Chemical Science and Engineering, 2021, 15 : 1572 - 1582
  • [10] Gold nanoparticles/single-stranded DNA-reduced graphene oxide nanocomposites based electrochemical biosensor for highly sensitive detection of cholesterol
    Wu, Shuyao
    Sui, Chengquan
    Wang, Chong
    Wang, Yulu
    He, Dongqing
    Sun, Ying
    Zhang, Yu
    Meng, Qingbo
    Ma, Tianyi
    Song, Xi-Ming
    FRONTIERS OF CHEMICAL SCIENCE AND ENGINEERING, 2021, 15 (06) : 1572 - 1582