Role of deep learning methods in screening for subcutaneous implantable cardioverter defibrillator in heart failure

被引:1
作者
ElRefai, Mohamed [1 ,2 ]
Abouelasaad, Mohamed [1 ]
Wiles, Benedict M. [3 ]
Dunn, Anthony J. [4 ]
Coniglio, Stefano [4 ]
Zemkoho, Alain B. [4 ]
Morgan, John M. [2 ]
Roberts, Paul R. [1 ,2 ]
机构
[1] Univ Hosp Southampton NHS Fdn Trust, Cardiac Rhythm Management Res Dept, Southampton, England
[2] Univ Southampton, Fac Med, Southampton, England
[3] Aberdeen Royal Infirm NHS trust, Aberdeen, Scotland
[4] Univ Southampton, Sch Math Sci, Southampton, England
关键词
artificial intelligence; heart failure; machine learning; subcutaneous implantable cardiac defibrillator; sudden cardiac death; AMPLITUDE; ANASARCA; INTERVAL;
D O I
10.1111/anec.13028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionS-ICD eligibility is assessed at pre-implant screening where surface ECG traces are used as surrogates for S-ICD vectors. In heart failure (HF) patients undergoing diuresis, electrolytes and fluid shifts can cause changes in R and T waves. Subsequently, T:R ratio, a major predictor of S-ICD eligibility, can be dynamic. MethodsThis is a prospective study of patients with structurally normal hearts and HF patients undergoing diuresis. All patients were fitted with Holters (R) to record their S-ICD vectors. Our deep learning model was used to analyze the T:R ratios across the recordings. Welch two sample t-test and Mann-Whitney U were used to compare the data between the two groups. ResultsTwenty-one patients (age 58.43 +/- 18.92, 62% male, 14 HF, 7 normal hearts) were enrolled. There was a significant difference in the T:R ratios between both groups. Mean T: R was higher in the HF group (0.18 +/- 0.08 vs 0.10 +/- 0.05, p < .001). Standard deviation of T: R was also higher in the HF group (0.09 +/- 0.05 vs 0.07 +/- 0.04, p = .024). There was no difference between leads within the same group. ConclusionsT:R ratio, a main determinant for S-ICD eligibility, is higher and has more tendency to fluctuate in HF patients undergoing diuresis. We hypothesize that our novel neural network model could be used to select HF patients eligible for S-ICD by better characterization of T:R ratio reducing the risk of T-wave over-sensing (TWO) and inappropriate shocks. Further work is required to consolidate our findings before applying to clinical practice.
引用
收藏
页数:9
相关论文
共 31 条
[11]   Head-To-Head Comparison of Arrhythmia Discrimination Performance of Subcutaneous and Transvenous ICD Arrhythmia Detection Algorithms: The START Study [J].
Gold, Michael R. ;
Theuns, Dominic A. ;
Knight, Bradley P. ;
Sturdivant, J. Lacy ;
Sanghera, Rick ;
Ellenbogen, Kenneth A. ;
Wood, Mark A. ;
Burke, Martin C. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (04) :359-366
[12]   Relation between Beat-to-Beat QT Interval Variability and T-Wave Amplitude in Healthy Subjects [J].
Hasan, Muhammad A. ;
Abbott, Derek ;
Baumert, Mathias .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2012, 17 (03) :195-203
[13]   Explainable artificial intelligence to detect atrial fibrillation using electrocardiogram [J].
Jo, Yong-Yeon ;
Cho, Younghoon ;
Lee, Soo Youn ;
Kwon, Joon-myoung ;
Kim, Kyung-Hee ;
Jeon, Ki-Hyun ;
Cho, Soohyun ;
Park, Jinsik ;
Oh, Byung-Hee .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 328 :104-110
[14]   The subcutaneous implantable cardioverter-defibrillator in review [J].
Kamp, Nicholas J. ;
Al-Khatib, Sana M. .
AMERICAN HEART JOURNAL, 2019, 217 :131-139
[15]   Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks [J].
Kiranyaz, Serkan ;
Ince, Turker ;
Gabbouj, Moncef .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (03) :664-675
[16]   Comprehensive electrocardiographic diagnosis based on deep learning [J].
Lih, Oh Shu ;
Jahmunah, V. ;
San, Tan Ru ;
Ciaccio, Edward J. ;
Yamakawa, Toshitaka ;
Tanabe, Masayuki ;
Kobayashi, Makiko ;
Faust, Oliver ;
Acharya, U. Rajendra .
ARTIFICIAL INTELLIGENCE IN MEDICINE, 2020, 103
[17]   Real-Time Multilead Convolutional Neural Network for Myocardial Infarction Detection [J].
Liu, Wenhan ;
Zhang, Mengxin ;
Zhang, Yidan ;
Liao, Yuan ;
Huang, Qijun ;
Chang, Sheng ;
Wang, Hao ;
He, Jin .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (05) :1434-1444
[18]   QTc interval in patients with changing edematous states: Implications on interpreting repeat QTc interval measurements in patients with anasarca of varying etiology and those undergoing hemodialysis [J].
Madias, JE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (01) :54-61
[19]   Anasarca-mediated attenuation of the amplitude of electrocardiogram complexes: A description of a heretofore unrecognized phenomenon [J].
Madias, JE ;
Bazaz, R ;
Agarwal, H ;
Win, M ;
Medepalli, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) :756-764
[20]   Continuous blood pressure measurement from one-channel electrocardiogram signal using deep-learning techniques [J].
Miao, Fen ;
Wen, Bo ;
Hu, Zhejing ;
Fortino, Giancarlo ;
Wang, Xi-Ping ;
Liu, Zeng-Ding ;
Tang, Min ;
Li, Ye .
ARTIFICIAL INTELLIGENCE IN MEDICINE, 2020, 108