Efficacy and Safety of the Medium Cut-Off Elisio HX Dialyzer

被引:5
|
作者
Maduell, Francisco [1 ,2 ]
Broseta, Jose Jesus [1 ]
Rodriguez-Espinosa, Diana [1 ]
Del Risco-Zevallos, Jimena [1 ]
Gomez, Miquel [1 ]
Rodas, Lida M. [1 ]
Arias-Guillen, Marta [1 ]
Vera, Manel [1 ]
Fontsere, Nestor [1 ]
Salgado, Maria del Carmen [3 ]
Rico, Nayra [3 ]
机构
[1] Hosp Clin Barcelona, Dept Nephrol, Barcelona, Spain
[2] Univ Barcelona, Dept Med, Barcelona, Spain
[3] Hosp Clin Barcelona, Dept Biochem, Barcelona, Spain
关键词
Dialyzer performance; Expanded hemodialysis; Helixone; Hemodiafiltration; Polyethersulfone; HEMODIAFILTRATION; HEMODIALYSIS;
D O I
10.1159/000524644
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. Methods: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ss(2)-microglobulin, myoglobin, kappa FLC, prolactin, alpha(1)-microglobulin, alpha(1)-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. Results: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. Conclusions: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.
引用
收藏
页码:68 / 74
页数:7
相关论文
共 50 条
  • [1] Assessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Haemodiafiltration
    Marcello, Matteo
    Simonini, Marco
    Lorenzin, Anna
    Corradi, Valentina
    Virzi, Grazia Maria
    Caprara, Carlotta
    Brendolan, Alessandra
    Benedetti, Claudia
    Lentini, Paolo
    Zanella, Monica
    Ronco, Claudio
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [2] Efficacy of Medium Cut-Off Dialyzer and Comparison with Standard High-Flux Hemodialysis
    Bushljetik, Irena Rambabova
    Trajceska, Lada
    Biljali, Sefedin
    Balkanov, Trajan
    Dejanov, Petar
    Spasovski, Goce
    BLOOD PURIFICATION, 2021, 50 (4-5) : 492 - 498
  • [3] Experience of using hemodialysis with medium cut-off dialyzer in cast nephropathy
    Cazorla Lopez, Juan Manuel
    Garcia Garcia-Doncel, Ana
    Naranjo Munoz, Javier
    Villanego Fernandez, Florentino
    Vigara Sanchez, Luis Alberto
    Ceballos Guerrero, Manuel
    NEFROLOGIA, 2020, 40 (03): : 367 - 369
  • [4] IMPACT OF A MEDIUM CUT-OFF DIALYZER ON SKIN AUTOFLUORESCENCE IN HAEMODIALYSIS PATIENTS
    Horner, Daniela Viramontes
    Kolhe, Nitin
    Leung, Janson
    Fluck, Richard
    Selby, Nicholas
    Taal, Maarten
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 1405 - 1405
  • [5] The possible usefulness of a medium cut-off dialyzer in a patient with cardiomyopathy of unclear origin
    Szewczyk, Bartlomiej A.
    Holownia, Kamila
    Jaroszynski, Andrzej
    MEDICAL STUDIES-STUDIA MEDYCZNE, 2022, 38 (03) : 258 - 261
  • [6] Protein Loss with Medium Cut-Off and High Flux Dialyzer: A Proteomic Analysis
    Wang, Xiaoling
    Tao, Xia
    Silva, Leticia M. Tapia
    Patel, Amrish U.
    Hakim, Mohamad I.
    Grobe, Nadja
    Thijssen, Stephan
    Kotanko, Peter
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 316 - 316
  • [7] Improved Removal of Free Light Chains by Hemodialysis With Medium Cut-Off Dialyzer
    Lee, Eun
    Jhee, Jong Hyun
    Park, Hyeong Cheon
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 717 - 718
  • [8] LONG TERM EFFECT OF MEDIUM CUT-OFF DIALYZER ON MIDDLE UREMIC TOXINS
    Rambabova-Bushljetik, Irena
    Shterjova-Markovska, Zhaklina
    Taneska, Aleksandra Canevska
    Janevski, Zoran
    Filipovski, Stefan
    Nikolov, Igor
    Severova-Andreevska, Galina
    Bushljetikj, Oliver
    Gjorgjievski, Nikola
    Pushevski, Vladimir
    Spasovski, Goce
    Trajcheska, Lada
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I709 - I709
  • [9] EFFICACY OF MEDIUM CUT-OFF DIALYZER AND COMPARISON WITH STANDARD HIGH-FLUX HEMODIALYSIS AND PREDILUTION ONLINE HEMODIAFILTRATION
    Kim, Tae Hoon
    Lee, Moon Hyoung
    Lee, Jung Eun
    Kim, Hyunwook
    Choi, Hoon Young
    Park, Hyeong Cheon
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [10] Medium cut-off dialyzer for middle molecular uremic toxins in AKI and chronic dialysis
    Fiorentino, Marco
    La Fergola, Francesco
    De Rosa, Silvia
    JOURNAL OF NEPHROLOGY, 2024, 37 (01) : 23 - 37