Facile one pot synthesis of sulphur doped graphene for non-enzymatic sensing of hydrogen peroxide

被引:2
作者
Kanuganti, Saritha Rani [1 ,2 ]
Sultana, Rafiya [2 ]
Kolli, Deepti [3 ]
Maddula, Gnana Kiran [4 ]
Singampalli, Mutta Reddy [1 ]
机构
[1] Acharya Nagarjuna Univ, Dept Chem, Guntur, Andhra Pradesh, India
[2] Govt Degree Coll Women, Dept Chem, Hyderabad, India
[3] Koneru Lakshmaiah Educ Fdn KLEF, Dept Chem, Guntur, Andhra Pradesh, India
[4] Koneru Lakshmaiah Educ Fdn KLEF, Dept Phys, Guntur, Andhra Pradesh, India
关键词
Sulphur doped graphene; chronoamperometry; cyclic voltammetry; hydrogen peroxide; ELECTROCHEMICAL DETECTION; OXYGEN REDUCTION; NITROGEN; NANOSHEETS; H2O2; NANOCOMPOSITES; EFFICIENT; NANOPARTICLES; ENERGY;
D O I
10.1080/03067319.2021.1980785
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein we demonstrated the preparation of sulphur-doped graphene (SG) prepared via hydrothermal route. The resulted material is used for making highly sensitive and selective electrochemical sensor platform for accurate quantification of Hydrogen Peroxide (H2O2). Structural features and surface morphology of synthesised materials are fully examined using High resolution Transmission electron microscopy (HRTEM), Scanning electron microscopy (SEM), FT-IR and Raman spectroscopy techniques. In addition to that, electrochemical techniques like cyclic voltammetry (CV) and chronoamperometry (CA) are used to quantify the electron transfer kinetics and electro catalytic activity, these results inveterate it is due to strong electron donating ability of doped sulphur (S) atom and edge plane sites in SG that promotes the electron transfer process at electrode-electrolyte interface. The SG modified glassy carbon electrode (SG/GCE) exhibited finite selectivity; sensitivity stability with a regression coefficient (R-2) value is 0.99 towards H2O2 estimation. The above observation conclude that these results are finest report to scrutinise the electrochemical properties of Graphene network by doping with Sulphur atom and it served as an important benchmark for the development of inexpensive SG based sensor platforms for electrochemical biosensor applications.
引用
收藏
页码:8051 / 8062
页数:12
相关论文
共 50 条
[21]   Crumpled Graphene/Poly (azure I) Modified Electrode for Non-enzymatic Detection of Hydrogen Peroxide Secreted from Tumor Cells [J].
Zhang, Keying ;
Zhang, Ziqiang ;
Ma, Shangshang ;
Cheng, Deshun ;
Fan, Mengdi ;
Zhou, Xinyu ;
Li, Fajun ;
Zhang, Na .
ANALYTICAL SCIENCES, 2021, 37 (10) :1367-1372
[22]   Green facile synthesis of biowaste-converted Cu-Cu2O/BPC for non-enzymatic hydrogen peroxide sensing [J].
Liu, Dong ;
Cao, Wenbin ;
Li, Fan ;
Ding, Yigang ;
Fan, Baomin .
DIAMOND AND RELATED MATERIALS, 2022, 130
[23]   A non-enzymatic hydrogen peroxide sensor based on dendrimer functionalized magnetic graphene oxide decorated with palladium nanoparticles [J].
Baghayeri, Mehdi ;
Alinezhad, Heshmatollah ;
Tarahomi, Mehrasa ;
Fayazi, Maryam ;
Ghanei-Motlagh, Masoud ;
Maleki, Behrooz .
APPLIED SURFACE SCIENCE, 2019, 478 :87-93
[24]   Preparation of reduced graphene oxide decorated with high density Ag nanorods for non-enzymatic hydrogen peroxide detection [J].
Yu, Bo ;
Feng, Jianchao ;
Liu, Sen ;
Zhang, Tong .
RSC ADVANCES, 2013, 3 (34) :14303-14307
[25]   Facile fabrication and enhanced properties of copper-based metal organic framework incorporated with graphene for non-enzymatic detection of hydrogen peroxide [J].
Golsheikh, Amir Moradi ;
Yeap, Guan-Yeow ;
Yam, Fong Kwong ;
Lim, Hwee San .
SYNTHETIC METALS, 2020, 260
[26]   Facile two-step Electrodeposition Synthesis of CuO Nanowires for Ultrasensitive Non-Enzymatic Sensing of Glucose [J].
Zhang, Di ;
Wei, Yuyun ;
Zhao, Meidan ;
Wang, Hong ;
Xia, Qing ;
Fang, Yuxin .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (12) :10835-10847
[27]   Laser-induced Graphene-based Non-enzymatic Sensor for Detection of Hydrogen Peroxide [J].
Zhang, Yuhan ;
Zhu, Huichao ;
Sun, Pin ;
Sun, Chang-Kai ;
Huang, Hui ;
Guan, Shui ;
Liu, Hailong ;
Zhang, Hangyu ;
Zhang, Chi ;
Qin, Kai-Rong .
ELECTROANALYSIS, 2019, 31 (07) :1334-1341
[28]   Graphene oxide-Cu(II) composite electrode for non-enzymatic determination of hydrogen peroxide [J].
Muralikrishna, S. ;
Cheunkar, Sarawut ;
Lertanantawong, Benchaporn ;
Ramakrishnappa, T. ;
Nagaraju, D. H. ;
Surareungchai, Werasak ;
Balakrishna, R. Geetha ;
Reddy, K. Ramakrishna .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 776 :59-65
[29]   Non-Enzymatic Amperometric Sensing of Hydrogen Peroxide Based on Vanadium Pentoxide Nanostructures [J].
Ghanei-Motlagh, Masoud ;
Taher, Mohammad Ali ;
Fayazi, Maryam ;
Baghayeri, Mehdi ;
Hosseinifar, AbduRahman .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) :B367-B372
[30]   Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with the layered MoS2-reduced graphene oxide and Prussian Blue [J].
Cheng, Zhenyu ;
Shen, Qihui ;
Yu, Huashi ;
Han, Dandan ;
Zhong, Fangli ;
Yang, Yingjie .
MICROCHIMICA ACTA, 2017, 184 (12) :4587-4595