Optimising internal curing parameters for autonomous curing of normal-strength concrete

被引:1
作者
Atsbha, Tesfaalem Gereziher [1 ]
Zhutovsky, Semion [1 ]
机构
[1] Technion Israel Inst Technol, Fac Civil & Environm Engn, Haifa, Israel
关键词
carbonation; curing; durability-related properties; permeability & pore-related properties; porosimetry; PROTECTED PASTE VOLUME; PORE-SIZE DISTRIBUTION; SUPERABSORBENT POLYMERS; CEMENT PASTES; LOW WATER; LIGHTWEIGHT; SHRINKAGE; EFFICIENCY; HYDRATION; AGENT;
D O I
10.1680/jmacr.22.00254
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Autogenous curing, also known as internal curing (IC), has revolutionised the way high-performance concrete (HPC) and high-strength concrete (HSC) are cured. IC improves the service life of concrete by lowering early-age cracking and enhancing durability. However, normal-strength concrete (NSC), the most commonly used type in the industry, is typically cured using conventional methods. Researchers are thus looking at ways to reproduce the positive results found in internally cured HSC/HPC in NSC. Studies have shown that IC is feasible in NSC despite its higher permeability, which results in loss of internal curing water (ICW). However, no comprehensive study has attempted to assess how the type, size and amount of IC agents affect the properties of NSC. The aim of this work was thus to optimise IC parameters for autonomous curing of NSC. The findings of this study support the notion that IC is possible in concrete with a high water/cement ratio and that, compared with lightweight aggregates (LWAs), superabsorbent polymers significantly impacted the durability properties of the NSC. Moreover, varying the size of the IC agent (LWA) had little effect on NSC properties, while increasing the amount of ICW considerably improved the durability properties.
引用
收藏
页码:888 / 905
页数:18
相关论文
共 91 条
[1]  
Abdelaziz G.E., 2006, 6 AS PAC STRUCT ENG
[2]  
ACI, 2014, PRC21314 ACI
[3]  
ACI (American Concrete Institute), 2008, 308R01 ACI
[4]   Effects of distribution of lightweight aggregates on internal curing of concrete [J].
Akcay, Burcu ;
Tasdemir, Mehmet Ali .
CEMENT & CONCRETE COMPOSITES, 2010, 32 (08) :611-616
[5]  
Akinwumi II., 2014, INT J CIV ENV RES, V1, P83
[6]  
Aligizaki K.K., 2005, PORE STRUCTURE CEMEN
[7]  
Angst U., 2019, P 10 INT C FRACT MEC, DOI DOI 10.21012/FC10.233307
[8]  
[Anonymous], 2022, Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
[9]  
[Anonymous], 2013, Standard test method for measurement of absorption of water by hydrauliccement concretes
[10]  
[Anonymous], 2013, BS EN 206: 2013