Effect of Clutter Filter in High-Frame-Rate Ultrasonic Backscatter Coefficient Analysis

被引:4
作者
Omura, Masaaki [1 ]
Yagi, Kunimasa [2 ]
Nagaoka, Ryo [1 ]
Yoshida, Kenji [3 ]
Yamaguchi, Tadashi [3 ]
Hasegawa, Hideyuki [1 ]
机构
[1] Univ Toyama, Fac Engn, Toyama 9308555, Japan
[2] Kanazawa Med Univ, Sch Med, Kanazawa 9200293, Japan
[3] Chiba Univ, Ctr Frontier Med Engn, Chiba 2638522, Japan
关键词
quantitative ultrasound; high-frame-rate imaging; backscatter coefficient; clutter filter; hemorheology; red blood cell; FLOWING WHOLE-BLOOD; ERYTHROCYTE AGGREGATION; DOPPLER; DEPENDENCE; VALIDATION; REDUCTION; FREQUENCY; ARTERY;
D O I
10.3390/s23052639
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-frame-rate imaging with a clutter filter can clearly visualize blood flow signals and provide more efficient discrimination with tissue signals. In vitro studies using clutter-less phantom and high-frequency ultrasound suggested a possibility of evaluating the red blood cell (RBC) aggregation by analyzing the frequency dependence of the backscatter coefficient (BSC). However, in in vivo applications, clutter filtering is required to visualize echoes from the RBC. This study initially evaluated the effect of the clutter filter for ultrasonic BSC analysis for in vitro and preliminary in vivo data to characterize hemorheology. Coherently compounded plane wave imaging at a frame rate of 2 kHz was carried out in high-frame-rate imaging. Two samples of RBCs suspended by saline and autologous plasma for in vitro data were circulated in two types of flow phantoms without or with clutter signals. The singular value decomposition was applied to suppress the clutter signal in the flow phantom. The BSC was calculated using the reference phantom method, and it was parametrized by spectral slope and mid-band fit (MBF) between 4-12 MHz. The velocity distribution was estimated by the block matching method, and the shear rate was estimated by the least squares approximation of the slope near the wall. Consequently, the spectral slope of the saline sample was always around four (Rayleigh scattering), independently of the shear rate, because the RBCs did not aggregate in the solution. Conversely, the spectral slope of the plasma sample was lower than four at low shear rates but approached four by increasing the shear rate, because the aggregations were presumably dissolved by the high shear rate. Moreover, the MBF of the plasma sample decreased from -36 to -49 dB in both flow phantoms with increasing shear rates, from approximately 10 to 100 s(-1). The variation in the spectral slope and MBF in the saline sample was comparable to the results of in vivo cases in healthy human jugular veins when the tissue and blood flow signals could be separated.
引用
收藏
页数:14
相关论文
共 46 条
[1]   In vivo measurement of attenuation coefficient of blood in a dorsal hand vein in a frequency range of 10-45 MHz: A preliminary study [J].
Arakawa, Mototaka ;
Higashiyama, Kyohei ;
Mori, Shohei ;
Yashiro, Satoshi ;
Ishigaki, Yasushi ;
Kanai, Hiroshi .
FRONTIERS IN PHYSICS, 2023, 11
[2]   Adaptive Spatiotemporal SVD Clutter Filtering for Ultrafast Doppler Imaging Using Similarity of Spatial Singular Vectors [J].
Baranger, Jerome ;
Arnal, Bastien ;
Perren, Fabienne ;
Baud, Olivier ;
Tanter, Mickael ;
Demene, Charlie .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (07) :1574-1586
[3]   Clutter filter design for ultrasound color flow imaging [J].
Bjærum, S ;
Torp, H ;
Kirstoffersen, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (02) :204-216
[4]   METHODS FOR ESTIMATION OF SUBSAMPLE TIME DELAYS OF DIGITIZED ECHO SIGNALS [J].
CESPEDES, I ;
HUANG, Y ;
OPHIR, J ;
SPRATT, S .
ULTRASONIC IMAGING, 1995, 17 (02) :142-171
[5]   RED-BLOOD-CELL AGGREGABILITY IN PATIENTS WITH A HISTORY OF LEG VEIN-THROMBOSIS - INFLUENCE OF POSTTHROMBOTIC TREATMENT [J].
CHABANEL, A ;
HORELLOU, MH ;
CONARD, J ;
SAMAMA, MM .
BRITISH JOURNAL OF HAEMATOLOGY, 1994, 88 (01) :174-179
[6]   Pilot clinical study of quantitative ultrasound spectroscopy measurements of erythrocyte aggregation within superficial veins [J].
Chayer, Boris ;
Allard, Louise ;
Qin, Zhao ;
Garcia-Duitama, Julian ;
Roger, Laurence ;
Destrempes, Francois ;
Cailhier, Jean-Francois ;
Denault, Andre ;
Cloutier, Guy .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 74 (02) :109-126
[7]   Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity [J].
Demene, Charlie ;
Deffieux, Thomas ;
Pernot, Mathieu ;
Osmanski, Bruno-Felix ;
Biran, Valerie ;
Gennisson, Jean-Luc ;
Sieu, Lim-Anna ;
Bergel, Antoine ;
Franqui, Stephanie ;
Correas, Jean-Michel ;
Cohen, Ivan ;
Baud, Olivier ;
Tanter, Mickael .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (11) :2271-2285
[8]   SOUND SCATTERING BY SOLID CYLINDERS AND SPHERES [J].
FARAN, JJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1951, 23 (04) :405-418
[9]  
Fornal M, 2006, CLIN HEMORHEOL MICRO, V35, P273
[10]   Estimation of Scatterer Diameter by Normalized Power Spectrum of High-FrequencyUltrasonic RF Echo for Assessment of Red Blood Cell Aggregation [J].
Fukushima, Taku ;
Hasegawa, Hideyuki ;
Kanai, Hiroshi .
JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (07)