Proposing of SPR biosensor based on 2D Ti3C2Tx MXene for uric acid detection immobilized by uricase enzyme

被引:15
作者
Ghodrati, Maryam [1 ]
Mir, Ali [1 ]
Farmani, Ali [1 ]
机构
[1] Lorestan Univ, Fac Engn, Khorramabad, Iran
关键词
Surface plasmon resonance; Ti3C2Tx MXene; Uric acid; Biosensor; Sensitivity; SURFACE-PLASMON RESONANCE; GRAPHENE; LAYER;
D O I
10.1007/s10825-022-01959-w
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a surface plasmon resonance (SPR) biosensor based on Ti3C2Tx MXene two-dimensional material to detect uric acid by utilizing urate oxidase enzyme. The proposed biosensor is a free space structure using Kretschmann configuration to stimulate the surface plasmons. The structure consists of SF11 prism, BK7 glass, silver (Ag), tungsten disulfide (WS2), graphene, Ti3C2Tx MXene, and the sensing medium. The minimum reflection, sensitivity, figure of merit, and detection accuracy of the SPR are investigated using the numerical method of FDTD in the visible region. Molarity varies from 0 to 500 ppm and refractive index from 1.3300 to 1.3336 for the sensing layer. The results indicate that the highest sensitivity of 273.53 deg/RIU can be achieved with a thickness of 50 nm Ag and a monolayer of WS2, a monolayer of graphene, and four layers of Ti3C2Tx MXene, at 633 nm wavelength.
引用
收藏
页码:560 / 569
页数:10
相关论文
共 50 条
[41]   Engineering the decay time of Ti3C2Tx MXene by gold nanoparticle decoration [J].
Rajput, Gaurav ;
Rawat, Ankita ;
Chourasia, Nitesh K. ;
Jalendra, Gaurav ;
Gupta, Govind ;
Yadav, Aditya ;
Kulriya, P. K. .
NANOTECHNOLOGY, 2025, 36 (15)
[42]   Micromechanics of Ti3C2Tx MXene reinforced poly(vinyl alcohol) nanocomposites [J].
Dong, Ming ;
Hu, Yi ;
Zhang, Han ;
Bilotti, Emiliano ;
Pugno, Nicola ;
Dunstan, David ;
Papageorgiou, Dimitrios G. .
COMPOSITES PART C: OPEN ACCESS, 2024, 13
[43]   Ti3C2Tx MXene based hybrid electrodes for wearable supercapacitors with varied deformation capabilities [J].
Zhang, Jingmin ;
Jiang, Degang ;
Liao, Leiping ;
Cui, Liang ;
Zheng, Rongkun ;
Liu, Jingquan .
CHEMICAL ENGINEERING JOURNAL, 2022, 429
[44]   Sensitivity-Enhanced Surface Plasmon Resonance Sensor with Bimetal/ Tungsten Disulfide (WS2)/MXene (Ti3C2Tx) Hybrid Structure [J].
Ghodrati, Maryam ;
Mir, Ali ;
Farmani, Ali .
PLASMONICS, 2022, 17 (05) :1973-1984
[45]   Detection of Uric Acid Using Kretschmann-based SPR Biosensor with MoS2-Graphene [J].
Jamil, Nur Akmar ;
Mei, Gan Siew ;
Khairulazdan, Nurkhairul Bariyah ;
Thiagarajah, Siva Priya ;
Hamzah, Azrul Azlan ;
Majlis, Burhanuddin Yeop ;
Menon, P. Susthitha .
2018 IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED), 2018,
[46]   Ecotoxicological assessment of Ti3C2Tx (MXene) using a zebrafish embryo model [J].
Nasrallah, Gheyath K. ;
Al-Asmakh, Maha ;
Rasool, Kashif ;
Mahmoud, Khaled A. .
ENVIRONMENTAL SCIENCE-NANO, 2018, 5 (04) :1002-1011
[47]   Electrochemical biosensors based on Ti3C2Tx MXene: future perspectives for on-site analysis [J].
Mathew, Minu ;
Rout, Chandra Sekhar .
CURRENT OPINION IN ELECTROCHEMISTRY, 2021, 30
[48]   Layer-dependent frictional properties of Ti3C2Tx MXene nanosheets [J].
Pendyala, Prashant ;
Lee, Juyun ;
Kim, Seon Joon ;
Yoon, Eui-Sung .
APPLIED SURFACE SCIENCE, 2022, 603
[49]   Understanding the swelling behavior of Ti3C2Tx MXene membranes in aqueous media [J].
Helal, Mohamed I. ;
Sinopoli, Alessandro ;
Gladich, Ivan ;
Tong, Yongfeng ;
Alfahel, Radwan ;
Gomez, Tricia ;
Mahmoud, Khaled A. .
JOURNAL OF MATERIALS CHEMISTRY A, 2024, 12 (44) :30729-30742
[50]   Room temperature gas sensors for NH3 detection based on the heterojunction of 2D Ti3C2Tx MXenes and Bi2S3 [J].
Zhao, Zhihua ;
Su, Zijie ;
Lv, Zhenli ;
Shi, Pu ;
Jin, Guixin ;
Wu, Lan .
MICROCHIMICA ACTA, 2024, 191 (11)