Cerebral Glutamate Alterations Using Chemical Exchange Saturation Transfer Imaging in a Rat Model of Lipopolysaccharide-Induced Sepsis

被引:5
|
作者
Lee, Do-Wan [1 ]
Kwon, Jae-Im [2 ,3 ]
Heo, Hwon [4 ]
Woo, Chul-Woong [5 ]
Yu, Na Hee [3 ]
Kim, Kyung Won [1 ,2 ]
Woo, Dong-Cheol [2 ,4 ,5 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Radiol, Coll Med, Seoul 05505, South Korea
[2] Univ Ulsan, Asan Med Inst Convergence Sci & Technol, Asan Med Ctr, Dept Med Sci,Coll Med, Seoul, South Korea
[3] QuBEST BIO Inc, Nonclin Res Ctr, Yongin 17015, Gyeonggi Do, South Korea
[4] Univ Ulsan, Asan Med Ctr, Dept Convergence Med, Coll Med, Seoul 05505, South Korea
[5] Asan Med Ctr, Asan Inst Life Sci, Convergence Med Res Ctr, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
glutamate; chemical exchange saturation transfer; lipopolysaccharide; sepsis; MAGNETIC-RESONANCE-SPECTROSCOPY; CLINICAL-APPLICATIONS; BRAIN; MICROGLIA; RELIABILITY; ACTIVATION; CONTRAST; PET;
D O I
10.3390/metabo13050636
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Glutamate-weighted chemical exchange saturation transfer (GluCEST) is a useful imaging tool to detect glutamate signal alterations caused by neuroinflammation. This study aimed to visualize and quantitatively evaluate hippocampal glutamate alterations in a rat model of sepsis-induced brain injury using GluCEST and proton magnetic resonance spectroscopy (H-1-MRS). Twenty-one Sprague Dawley rats were divided into three groups (sepsis-induced groups (SEP05, n = 7 and SEP10, n = 7) and controls (n = 7)). Sepsis was induced through a single intraperitoneal injection of lipopolysaccharide (LPS) at a dose of 5 mg/kg (SEP05) or 10 mg/kg (SEP10). GluCEST values and H-1-MRS concentrations in the hippocampal region were quantified using conventional magnetization transfer ratio asymmetry and a water scaling method, respectively. In addition, we examined immunohistochemical and immunofluorescence staining to observe the immune response and activity in the hippocampal region after LPS exposure. The GluCEST and H-1-MRS results showed that GluCEST values and glutamate concentrations were significantly higher in sepsis-induced rats than those in controls as the LPS dose increased. GluCEST imaging may be a helpful technique for defining biomarkers to estimate glutamate-related metabolism in sepsis-associated diseases.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Pharmacologic studies on ET-26 hydrochloride in a rat model of lipopolysaccharide-induced sepsis
    Wang, Bin
    Jiang, Junli
    Yang, Jun
    Chen, Jun
    Zhu, Zhaoqiong
    Liu, Jin
    Zhang, Wensheng
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 109 : 441 - 445
  • [22] Molecular imaging of tumors and metastases using chemical exchange saturation transfer (CEST) MRI
    Rivlin, Michal
    Horev, Judith
    Tsarfaty, Ilan
    Navon, Gil
    SCIENTIFIC REPORTS, 2013, 3
  • [23] pH Imaging Using Chemical Exchange Saturation Transfer (CEST) MRI
    Pavuluri, KowsalyaDevi
    McMahon, Michael T.
    ISRAEL JOURNAL OF CHEMISTRY, 2017, 57 (09) : 862 - 879
  • [24] Visualization of Unconjugated Bilirubin In Vivo with a Novel Approach Using Chemical Exchange Saturation Transfer Magnetic Resonance Imaging in a Rat Model
    Yang, Lin
    Cheng, Yan
    Jia, Yanlong
    Cao, Zhen
    Zhuang, Zerui
    Zhang, Xiaolei
    Guan, Jitian
    Cai, Rongzhi
    Lin, Yan
    Wu, Renhua
    ACS CHEMICAL NEUROSCIENCE, 2024, : 4533 - 4543
  • [25] Protective effects of edaravone, a free radical scavenger, on lipopolysaccharide-induced acute kidney injury in a rat model of sepsis
    Liu, Lin
    Song, Yijin
    Zhao, Ming
    Yi, Zhuwen
    Zeng, Qiyi
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2015, 47 (10) : 1745 - 1752
  • [26] Comparison of Chemical Exchange Saturation Transfer Imaging with Diffusion-weighted Imaging and Magnetic Resonance Spectroscopy in a Rat Model of Hypoxic-ischemic Encephalopathy
    Ohki, Akiko
    Saito, Shigeyoshi
    Hirayama, Eri
    Takahashi, Yusuke
    Ogawa, Yuko
    Tsuji, Masahiro
    Higuchi, Takahiro
    Fukuchi, Kazuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 359 - 365
  • [27] Diamagnetic chemical exchange saturation transfer (diaCEST) affords magnetic resonance imaging of extracellular matrix hydrogel implantation in a rat model of stroke
    Jin, Tao
    Nicholls, Francesca J.
    Crum, William R.
    Ghuman, Harmanvir
    Badylak, Stephen F.
    Modo, Michel
    BIOMATERIALS, 2017, 113 : 176 - 190
  • [28] Temporal Changes in In Vivo Glutamate Signal during Demyelination and Remyelination in the Corpus Callosum: A Glutamate-Weighted Chemical Exchange Saturation Transfer Imaging Study
    Lee, Do-Wan
    Heo, Hwon
    Woo, Chul-Woong
    Woo, Dong-Cheol
    Kim, Jeong-Kon
    Kim, Kyung-Won
    Lee, Dong-Hoon
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (24) : 1 - 10
  • [29] Effects of S-allyl cysteine on lung and liver tissue in a rat model of lipopolysaccharide-induced sepsis
    Bayraktar, Orhan
    Tekin, Neslihan
    Aydin, Ozlem
    Akyuz, Fahrettin
    Musmul, Ahmet
    Burukoglu, Dilek
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2015, 388 (03) : 327 - 335
  • [30] The alteration of glutamate involved in the brain of Parkinson's disease patients using glutamate chemical exchange saturation transfer (GluCEST)
    Liu, Miaomiao
    Li, Minglong
    Du, Hailing
    Xu, Donghao
    Wang, Jing
    Ren, Qingfa
    Wang, Rui
    Gong, He
    Liu, Yuwei
    Qi, Kai
    Tao, Jin
    Xia, Shuyuan
    Wang, Hongcai
    Li, Xianglin
    Liu, Quanyuan
    BEHAVIOURAL BRAIN RESEARCH, 2025, 483