The first mobile photon-counting detector CT: the human images and technical performance study

被引:8
作者
Park, Su-Jin [1 ]
Park, Junyoung [1 ]
Kim, Doil [1 ]
Lee, Duhgoon [2 ]
Lee, Chang-Lae [1 ]
Bechwati, Ibrahim [2 ]
Wu, Dufan [3 ]
Gupta, Rajiv [3 ]
Jung, Jinwook [1 ]
机构
[1] Samsung Elect Co Ltd, Hlth & Med Equipment Business, 129 SamSung Ro, Suwon, Gyeonggi Do 16677, South Korea
[2] Samsung NeuroL, 14 Elect Ave, Danvers, MA 01923 USA
[3] Massachusetts Gen Hosp, Radiol, 55 Fruit St, Boston, MA 02114 USA
关键词
photon-counting detector; PCD-CT; human images; techincal performance; COMPUTED-TOMOGRAPHY;
D O I
10.1088/1361-6560/acc8b3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The purpose of this study is to assess its human images and its unique capabilities such as the 'on demand' higher spatial resolution and multi-spectral imaging of photon-counting-detector (PCD)-CT. Approach. In this study, the FDA 510(k) cleared mobile PCD-CT (OmniTom Elite) was used. To this end, we imaged internationally certified CT phantoms and a human cadaver head to evaluate the feasibility of high resolution (HR) and multi-energy imaging. We also demonstrate the performance of PCD-CT via first-in-human imaging by scanning three human volunteers. Main results. At the 5 mm slice thickness, routinely used in diagnostic head CT, the first human PCD-CT images were diagnostically equivalent to the EID-CT scanner. The HR acquisition mode of PCD-CT achieved a resolution of 11 line-pairs (lp)/cm as compared to 7 lp cm(-1) using the same kernel (posterior fossa-kernel) in the standard acquisition mode of EID-CT. For the quantitative multi-energy CT performance, the measured CT numbers in virtual mono-energetic images (VMI) of iodine inserts in the Gammex Multi-Energy CT phantom (model 1492, Sun Nuclear Corporation, USA) matched the manufacturer reference values with mean percent error of 3.25%. Multi-energy decomposition with PCD-CT demonstrated the separation and quantification of iodine, calcium, and water. Significance. PCD-CT can achieve multi-resolution acquisition modes without physically changing the CT detector. It can provide superior spatial resolution compared with the standard acquisition mode the conventional mobile EID-CT. Quantitative spectral capability of PCD-CT can provide accurate, simultaneous multi-energy images for material decomposition and VMI generation using a single exposure.
引用
收藏
页数:15
相关论文
共 18 条
[1]   A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT [J].
Cammin, Jochen ;
Xu, Jennifer ;
Barber, William C. ;
Iwanczyk, Jan S. ;
Hartsough, Neal E. ;
Taguchi, Katsuyuki .
MEDICAL PHYSICS, 2014, 41 (04)
[2]   Photon-counting x-ray detectors for CT [J].
Danielsson, Mats ;
Persson, Mats ;
Sjolin, Martin .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03)
[3]   Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies [J].
Gutjahr, Ralf ;
Halaweish, Ahmed F. ;
Yu, Zhicong ;
Leng, Shuai ;
Yu, Lifeng ;
Li, Zhoubo ;
Jorgensen, Steven M. ;
Ritman, Erik L. ;
Kappler, Steffen ;
McCollough, Cynthia H. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (07) :421-429
[4]  
Knoll G., 2010, Radiation detection and measurement
[5]  
Krauss B, 2015, INVEST RADIOL, V50, P114, DOI 10.1097/RLI.0000000000000109
[6]   Bringing CT Scanners to the Skies: Design of a CT Scanner for an Air Mobile Stroke Unit [J].
Kwok, Jun Sheng ;
Fox, Kate ;
Bil, Cees ;
Langenberg, Francesca ;
Balabanski, Anna H. ;
Dos Santos, Angela ;
Bivard, Andrew ;
Gardiner, Fergus ;
Bladin, Christopher ;
Parsons, Mark ;
Zhao, Henry ;
Coote, Skye ;
Levi, Christopher ;
De Aizpurua, Henry ;
Campbell, Bruce ;
Davis, Stephen M. ;
Donnan, Geoffrey A. ;
Easton, Damien ;
Pang, Toh Yen .
APPLIED SCIENCES-BASEL, 2022, 12 (03)
[7]   Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications [J].
Lee, Chang-Lae ;
Hong, Key Jo ;
Kim, Namwoo ;
Han, Kwanhee ;
Kim, Dongkyu ;
Jung, Hoe-Su ;
Lee, Sangmin ;
Park, Junyoung ;
Lee, Kyoung-Yong ;
Lee, Jee Eun ;
Choi, Yuna ;
Cho, Minkook .
SCIENTIFIC REPORTS, 2021, 11 (01)
[8]   Ultra-High Spatial Resolution, Multi-Energy CT using Photon Counting Detector Technology [J].
Leng, S. ;
Gutjahr, R. ;
Ferrero, A. ;
Kappler, S. ;
Henning, A. ;
Halaweish, A. ;
Zhou, W. ;
Montoya, J. ;
McCollough, C. .
MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
[9]  
Leng S., 2016, PROC SPIE, P9783
[10]   Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology [J].
Leng, Shuai ;
Bruesewitz, Michael ;
Tao, Shengzhen ;
Rajendran, Kishore ;
Halaweish, Ahmed F. ;
Campeau, Norbert G. ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .