Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures

被引:1
|
作者
Zhang, Ru-Yi [1 ]
Zhang, Wu-Peng [2 ,3 ,4 ]
Yang, Guang-Min [5 ]
Wang, Dao-Feng [6 ]
Su, Peng [1 ]
Zhang, Yi [1 ]
Nie, Shao-Bo [2 ,3 ]
Li, Jia [2 ,3 ]
Zhao, Zhe [5 ,7 ]
Li, Jian-Tao [2 ,3 ,7 ]
Zhang, Li-Cheng [2 ,3 ,7 ]
Tang, Pei-Fu [2 ,3 ]
机构
[1] Capital Med Univ, Beijing Shijingshan Hosp, Shijingshan Teaching Hosp, Dept Orthopaed, Beijing, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 4, Dept Orthoped, Beijing, Peoples R China
[3] Natl Clin Res Ctr Orthoped Sports Med & Rehabil, Beijing, Peoples R China
[4] Nankai Univ, Sch Med, Tianjin, Peoples R China
[5] Tsinghua Univ, Sch Clin Med, Beijing Tsinghua Changgung Hosp, Dept Orthopaed, Beijing, Peoples R China
[6] Capital Med Univ, Beijing Jishuitan Hosp, Dept Sports Med, Sports Med Serv, Beijing, Peoples R China
[7] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 4, Dept Orthoped, Beijing, Peoples R China
关键词
Biomechanics; Cannulated Compression Screw; Femoral Neck Fracture; Oblique Triangle; Spatial Configuration; INTERNAL-FIXATION; NAIL;
D O I
10.1111/os.14004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Surgical treatment with internal fixation, specifically percutaneous fixation with three cannulated compression screws (CCSs), is the preferred choice for young and middle-aged patients. The mechanical advantage of the optimal spatial configuration with three screws provides maximum dispersion and cortical support. We suspect that the spatial proportion of the oblique triangle configuration (OTC) in the cross-section of the femoral neck isthmus (FNI) may significantly improve shear and fatigue resistance of the fixed structure, thereby stabilizing the internal fixation system in femoral neck fracture (FNF). This study aims to explore the mechanical features of OTC and provide a mechanical basis for its clinical application. Methods: Twenty Sawbone femurs were prepared as Pauwels type III FNF models and divided equally into two fixation groups: OTC and inverted equilateral triangle configuration (IETC). Three 7.3 mm diameter cannulated compression screws (CCSs) were used for fixation. The specimens of FNF after screw internal fixation were subjected to static loading and cyclic loading tests, respectively, with five specimens for each test. Axial stiffness, 5 mm failure load, ultimate load, shear displacement, and frontal rotational angle of two fragments were evaluated. In the cyclic loading test, the load sizes were 700 N, 1400 N, and 2100 N, respectively, and the fracture end displacement was recorded. Results were presented as means +/- SD. Data with normal distributions were compared by the Student's t test. Results: In the static loading test, the axial stiffness, ultimate load, shear displacement, and frontal rotational angle of two fragments were (738.64 vs. 620.74) N/mm, (2957.61 vs. 2643.06) N, (4.67 vs. 5.39) mm, and (4.01 vs. 5.52)degrees (p < 0.05), respectively. Comparison between the femoral head displacement after 10,000 cycles of 700N cyclic loading and total displacement after 20,000 cycles of 700-1400N cyclic loading showed the OTC group was less than the IETC group (p < 0.05). A comparison of femoral head displacement after 10,000 cycles of 1400N and 2100N cycles and total displacement after 30,000 cycles of 700-2100N cycles showed the OTC group was less than another group, but the difference was not significant (p > 0.05). Conclusion: When three CCSs are inserted in parallel to fix FNF, the OTC of three screws has obvious biomechanical advantages, especially in shear resistance and early postoperative weight-bearing, which provides a mechanical basis for clinical selection of ideal spatial configuration for unstable FNF.
引用
收藏
页码:953 / 964
页数:12
相关论文
共 50 条
  • [21] Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures
    Saglam, Necdet
    Kucukdurmaz, Fatih
    Kivilcim, Hakan
    Kurtulmus, Tuhan
    Sen, Cengiz
    Akpinar, Fuat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 196 - 201
  • [22] Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients
    Hu, Huaijian
    Cheng, Jingbo
    Feng, Mingli
    Gao, Zhihua
    Wu, Jingwei
    Lu, Shibao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [23] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [24] A prediction model for osteonecrosis of femoral head after internal fixation with multiple cannulated compression screws for adult femoral neck fractures
    Jin, Zhang
    Chen, Luo
    Wang, Dafeng
    Ye, Yayun
    Fu, Jiaxing
    Yang, Zhifan
    He, Baoqiang
    JOINT DISEASES AND RELATED SURGERY, 2024, 35 (01) : 20 - 26
  • [25] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [26] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Weil, Yoram A.
    Qawasmi, Feras
    Liebergall, Meir
    Mosheiff, Rami
    Khoury, Amal
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (05) : 661 - 667
  • [27] A comparative study of internal fixation with porous tantalum screws and cannulated screws in the treatment of femoral neck fractures
    Dewei Zhao
    Yu Zhang
    Liangliang Cheng
    Zhijie Ma
    Feng Wang
    Xing Qiu
    Jiawei Ying
    Tianwei Zhang
    Fuyang Wang
    Scientific Reports, 15 (1)
  • [28] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Baokun Zhang
    Jingwen Liu
    Yi Zhu
    Wei Zhang
    International Orthopaedics, 2018, 42 : 1949 - 1955
  • [29] Biomechanical analysis of the closed reduction internal fixation with cannulated screw of femoral neck fractures
    Wang, Jian-Guang
    Wu, Jun-Xian
    Li, Yu-Min
    Xu, You-Yin
    MEDICINE, 2021, 100 (08) : E24834
  • [30] Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients
    Huaijian Hu
    Jingbo Cheng
    Mingli Feng
    Zhihua Gao
    Jingwei Wu
    Shibao Lu
    Journal of Orthopaedic Surgery and Research, 16