The Use of a Closed Feed Frame for the Development of Near-Infrared Spectroscopic Calibration Model to Determine Drug Concentration

被引:0
作者
Movilla-Meza, Nathaly A. [1 ]
Sierra-Vega, Nobel O. [2 ]
Alvarado-Hernandez, Barbara B. [1 ]
Mendez, Rafael [2 ]
Romanach, Rodolfo J. [1 ,3 ]
机构
[1] Univ Puerto Rico, Dept Chem Engn, Mayaguez, PR 00680 USA
[2] Univ Puerto Rico, Dept Chem Engn, Mayaguez, PR USA
[3] Univ Puerto Rico, Ctr Struct Organ Particulate Syst C SOPS, Dept Chem, POB 9000, Mayaguez, PR 00681 USA
基金
瑞典研究理事会;
关键词
blend uniformity; calibration models; feed frame; near-infrared spectroscopy; process analytical technology; VARIOGRAPHIC ANALYSIS; METHODOLOGY; PREDICTION; DENSITY;
D O I
10.1007/s11095-023-03601-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
PurposeThis study evaluates the use of the closed feed frame as a material sparing approach to develop near-infrared (NIR) spectroscopic calibration models for monitoring blend uniformity. The effect of shear induced by recirculation on NIR spectra was also studied.MethodsCalibration models were developed using NIR spectra obtained in the closed feed frame for two cases. For case 2, blends that flowed through the open feed frame were predicted with the model. The shear effect of the feed frame on the blends was assessed through the characterization of powder properties before and after recirculation.ResultsThe physical characterization of the blends confirmed that the powder properties were not altered after recirculation within the closed feed frame. Both calibration models provided highly accurate predictions of the test sets with low bias (0.03% w/w and -0.06% w/w) and relative standard error of prediction (1.9% and 3.7%), respectively. The predictive performance of the calibration models was not affected by the shear effect.ConclusionRecirculation within the closed feed frame did not change the physical properties of the blends studied. The prediction of blends flowing through the open feed frame was possible with a calibration model developed in the closed feed frame. The closed feed frame could reduce the materials needed to develop calibration models by more than 90%.
引用
收藏
页码:2903 / 2916
页数:14
相关论文
共 38 条
  • [1] Benchtop NIR method development for continuous manufacturing scale to enable efficient PAT application for solid oral dosage form
    Alam, Md Anik
    Liu, Yang Angela
    Dolph, Stephanie
    Pawliczek, Marcin
    Peeters, Elisabeth
    Palm, Andrew
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 601
  • [2] A sampling system for flowing powders based on the theory of sampling
    Alvarado-Hernandez, Barbara B.
    Sierra-Vega, Nobel O.
    Martinez-Cartagena, Pedro
    Hormaza, Manuel
    Mendez, Rafael
    Romanach, Rodolfo J.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2020, 574
  • [3] [Anonymous], 2004, GUIDANCE IND 5 FRAME
  • [4] A novel method for determination of the filling level in the feed frame of a rotary tablet press
    Duehlmeyer, K. P.
    Oezcoban, H.
    Leopold, C. S.
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2018, 44 (11) : 1744 - 1751
  • [5] EMA, 2005, INT C HARMON
  • [6] EMA - European Medicines Agency, 2014, GUID US NEAR INFR SP
  • [7] Esbensen KH, 2009, COMPREHENSIVE CHEMOMETRICS: CHEMICAL AND BIOCHEMICAL DATA ANALYSIS, VOLS 1-4, pC1
  • [8] Adequacy and verifiability of pharmaceutical mixtures and dose units by variographic analysis (Theory of Sampling) - A call for a regulatory paradigm shift
    Esbensen, Kim H.
    Roman-Ospino, Andres D.
    Sanchez, Adriluz
    Romanach, Rodolfo J.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2016, 499 (1-2) : 156 - 174
  • [9] Representative sampling of large kernel lots I. Theory of Sampling and variographic analysis
    Esbensen, Kim H.
    Paoletti, Claudia
    Minkkinen, Pentti
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 32 : 154 - 164
  • [10] FDA, 2015, DEV SUBM NEAR INFR A