An intelligent protection scheme for series-compensated transmission lines connecting large-scale wind farms

被引:1
作者
Prabhu, M. S. [1 ]
Biswas, Sauvik [2 ]
Nayak, Paresh Kumar [3 ]
Abdelaziz, Almoataz [4 ]
El-Shahat, Adel [5 ]
机构
[1] Vel Tech Rangarajan Dr Sagunthala R&D Inst Sci & T, Elect & Elect Engn, Chennai, India
[2] Indian Inst Technol, Elect Engn, Delhi, India
[3] Indian Inst Technol ISM, Elect Engn, Dhanbad, India
[4] Future Univ Egypt, Fac Engn & Technol, Cairo, Egypt
[5] Purdue Univ, Sch Engn Technol, Energy Technol Program, W Lafayette, IN USA
关键词
series-compensated transmission line; DFIG-WTG; large-scale wind farm; distance relay; fault detection; fault classification; bagging ensemble classifier; FED INDUCTION GENERATOR; ADAPTIVE DISTANCE PROTECTION; FOURIER-BESSEL EXPANSION; CLASSIFICATION SCHEME; FAULT CLASSIFICATION; DYNAMIC-BEHAVIOR; TCSC; IDENTIFICATION; CIRCUIT; NETWORK;
D O I
10.3389/fenrg.2023.1141235
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Series-compensated transmission lines (SCTLs) are increasingly preferred for transmitting bulk amounts of electricity generated from the present-day large-scale wind farm to the utility grid due to several technical and economic benefits. However, when a fault occurs in such a wind farm-integrated SCTL, the impedance across the metal oxide varistor (MOV)-protected series capacitor varies non-linearly. Also, the fault current contributed from the wind farm side is quite different compared to the grid side. Consequently, the widely used fixed impedance-based distance relaying schemes showed limitations when used for protecting such crucial TLs. In this paper, the impacts of series compensation and wind farm integration on distance relay are investigated, and this paper proposes an intelligent relaying scheme using only the current measurements. In the proposed scheme, the fault detection task is performed using the signs of the half-cycle magnitude differences of the line end positive-sequence currents, and the fault classification task is performed using only the local current measurements processed through the Fourier-Bessel series expansion (FBSE) bagging ensemble (BE) classifier. The non-stationary components present in the current signal at the initiation of a fault are captured by calculating FBSE coefficients, and the singular value decomposition is applied for dimensionality reduction of the feature set. Finally, the extracted features are used by the BE classifier for fault classification. The method is evaluated in MATLAB/Simulink (R) on numerous fault and non-fault data simulated in two-bus systems and also validated through the OPAL-RT (OP4510) manufactured real-time digital simulation platform. The obtained results (response time for fault detection and classification < 10 m s ), including the comparative assessment results (fault detection accuracy = 100 % and fault classification accuracy = 99.37 % ), justify the effectiveness of the proposed relaying scheme in protecting the wind farm-integrated SCTLs.
引用
收藏
页数:17
相关论文
共 54 条
  • [1] Modem approaches for protection of series compensated transmission lines
    Abdelaziz, AY
    Ibrahim, AM
    Mansour, MM
    Talaat, HE
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2005, 75 (01) : 85 - 98
  • [2] Advances in Series-Compensated Line Protection
    Altuve, Hector J.
    Mooney, Joseph B.
    Alexander, George E.
    [J]. 2009 62ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2009, : 263 - 275
  • [3] A Dual-Time Transform Assisted Intelligent Relaying Scheme for the STATCOM-Compensated Transmission Line Connecting Wind Farm
    Biswas, Sauvik
    Nayak, Paresh
    Pradhan, Gayadhar
    [J]. IEEE SYSTEMS JOURNAL, 2022, 16 (02): : 2160 - 2171
  • [4] A New Approach for Protecting TCSC Compensated Transmission Lines Connected to DFIG-Based Wind Farm
    Biswas, Sauvik
    Nayak, Paresh Kumar
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2021, 17 (08) : 5282 - 5291
  • [5] A Fault Detection and Classification Scheme for Unified Power Flow Controller Compensated Transmission Lines Connecting Wind Farms
    Biswas, Sauvik
    Nayak, Paresh Kumar
    [J]. IEEE SYSTEMS JOURNAL, 2021, 15 (01): : 297 - 306
  • [6] An unblocking assistance to distance relays protecting TCSC compensated transmission lines during power swing
    Biswas, Sauvik
    Nayak, Paresh Kumar
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (08):
  • [7] Random forests
    Breiman, L
    [J]. MACHINE LEARNING, 2001, 45 (01) : 5 - 32
  • [8] Cental Electricity Regulatory Commision, 2010, IND EL GRID COD
  • [9] Wind energy development and policy in India: A review
    Chaurasiya, Prem Kumar
    Warudkar, Vilas
    Ahmed, Siraj
    [J]. ENERGY STRATEGY REVIEWS, 2019, 24 : 342 - 357
  • [10] Adaptive distance protection for grounded fault of lines connected with doubly-fed induction generators
    Chen, Shi
    Tai, Nengling
    Fan, Chunju
    Liu, Jian
    Hong, Shubin
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (06) : 1513 - 1520