Amniocentesis-When It Is Clear That It Is Not Clear

被引:5
作者
Ciortea, Razvan [1 ]
Malutan, Andrei Mihai [1 ]
Bucuri, Carmen Elena [1 ]
Berceanu, Costin [2 ]
Rada, Maria Patricia [1 ]
Ormindean, Cristina Mihaela [1 ]
Mihu, Dan [1 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Dept Obstet & Gynaecol 2, Cluj Napoca 400012, Romania
[2] Univ Med & Pharm Craiova, Emergency Univ Hosp Craiova, Dept Obstet & Gynecol, Craiova 200642, Romania
关键词
amniocentesis; contamination; technique; needle gauge; doppler; pregnancy; risk; MATERNAL CELL CONTAMINATION; 2ND TRIMESTER AMNIOCENTESIS; AMNIOTIC-FLUID; PRENATAL-DIAGNOSIS; DOWN-SYNDROME; SAMPLES; DNA; ANEUPLOIDY; STATEMENT; 20G;
D O I
10.3390/jcm12020454
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A fetus identified to be at risk for chromosomal abnormalities may benefit from identification of genetic defects through amniocentesis. Although the risks associated with amniocentesis are considered to be minimal, being an invasive procedure it is not completely without complications. Background and Objectives: The current study aims to identify correlations between blood contamination of samples collected during amniocentesis and certain factors dependent on the instruments used (thickness of the needle used to aspirate the fluid), the location of the placenta, and uterine vascularity (more pronounced in multiparous patients). Materials and Methods: The study included 190 patients in the second trimester of pregnancy who met one of the criteria for invasive prenatal diagnosis (age over 35 years, high risk in first trimester screening, history of pregnancies with genetic abnormalities, etc.). The amniotic fluid samples collected from these patients were analyzed in terms of blood contamination of the amniotic fluid aspirated with maternal cells Results: Of the patients in whom the procedure was performed using 21 G size needles, 16 samples (13.33% of the total) were contaminated. None of the samples collected from patients where a 20 G needle was used were contaminated. There was a statistically significant association between the lack of contamination and the use of Doppler ultrasound in multiparous patients with anterior placenta in whom a 21-gauge needle was used for amniocentesis. Conclusions: There is an increased rate of sample contamination (statistically significant) when using 21 G needle sizes and a significant difference in contamination between primiparous and multiparous patients, with contamination being more frequent in multiparous patients. The use of Doppler ultrasonography may benefit the procedure, as the contamination rate was significantly reduced when used during amniocentesis.
引用
收藏
页数:14
相关论文
共 27 条
[1]   Amniocentesis and chorionic villus sampling for prenatal diagnosis [J].
Alfirevic, Zarko ;
Navaratnam, Kate ;
Mujezinovic, Faris .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (09)
[2]   AMNIOCENTESIS AND ITS COMPLICATIONS [J].
ANANDAKUMAR, C ;
WONG, YC ;
ANNAPOORNA, V ;
ARULKUMARAN, S ;
CHIA, D ;
BONGSO, A ;
RATNAM, SS .
AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1992, 32 (02) :97-99
[3]  
[Anonymous], 2014, RCOG Scientific Impact Paper, V15, P1
[4]   Comparison between 20G and 22G needle for second trimester amniocentesis in terms of technical aspects and short-term complications [J].
Athanasiadis, Apostolos P. ;
Pantazis, Konstantinos ;
Goulis, Dimitrios G. ;
Chatzigeorgiou, Konstantinos ;
Vaitsi, Violeta ;
Assimakopoulos, Efstratios ;
Tzevelekis, Filippos ;
Tsalikis, Tryfon ;
Bontis, John N. .
PRENATAL DIAGNOSIS, 2009, 29 (08) :761-765
[5]   MATERNAL CELL CONTAMINATION OF AMNIOTIC-FLUID CELL-CULTURES - RESULTS OF A UNITED-STATES NATIONWIDE SURVEY [J].
BENN, PA ;
HSU, LYF .
AMERICAN JOURNAL OF MEDICAL GENETICS, 1983, 15 (02) :297-305
[6]   Prenatal Detection of Down Syndrome using Massively Parallel Sequencing (MPS): a rapid response statement from a committee on behalf of the Board of the International Society for Prenatal Diagnosis, 24 October 2011 [J].
Benn, Peter ;
Borrell, Antoni ;
Cuckle, Howard ;
Dugoff, Lorraine ;
Gross, Susan ;
Johnson, Jo-ann ;
Maymon, Ron ;
Odibo, Anthony ;
Schielen, Peter ;
Spencer, Kevin ;
Wright, Dave ;
Yaron, Yuval .
PRENATAL DIAGNOSIS, 2012, 32 (01) :1-2
[7]   Genome-Wide Fetal Aneuploidy Detection by Maternal Plasma DNA Sequencing [J].
Bianchi, Diana W. ;
Platt, Lawrence D. ;
Goldberg, James D. ;
Abuhamad, Alfred Z. ;
Sehnert, Amy J. ;
Rava, Richard P. .
OBSTETRICS AND GYNECOLOGY, 2012, 119 (05) :890-901
[8]  
Buchovecky CM, 2019, METHODS MOL BIOL, V1885, P117, DOI 10.1007/978-1-4939-8889-1_8
[9]   Prenatal Diagnosis Screening and Diagnostic Tools [J].
Carlson, Laura M. ;
Vora, Neeta L. .
OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 2017, 44 (02) :245-+
[10]   Role of late amniocentesis in the era of modern genomic technologies [J].
Daum, H. ;
Ben David, A. ;
Nadjari, M. ;
Zenvirt, S. ;
Helman, S. ;
Yanai, N. ;
Meiner, V. ;
Yagel, S. ;
Frumkin, A. ;
Rafid, S. Shkedi .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 53 (05) :676-685