Behaviour of CFRP confined square concrete-filled stainless steel tubular columns under uni-axial compression

被引:16
作者
Tang, Hongyuan [1 ]
Wang, Huixiang [1 ]
Liu, Ye [2 ]
Sun, Xujie [1 ]
Huang, Xiaogang [3 ]
机构
[1] Xihua Univ, Inst Struct Engn, Chengdu 610039, Peoples R China
[2] Sichuan Univ, Coll Architecture & Environm, Key Lab Deep Underground Sci & Engn, Minist Educ, Chengdu 610065, Peoples R China
[3] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
CFRP sheet; Concrete-filled stainless steel tube; Failure modes; Ultimate bearing capacity; Twin-shear unified strength theory; STRESS-STRAIN MODEL; TUBE COLUMNS; STRUCTURAL PERFORMANCE; STUB COLUMNS; DESIGN; STRENGTH;
D O I
10.1016/j.tws.2022.110440
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the behaviour of the carbon fibre-reinforced polymer (CFRP) confined square concrete-filled stainless steel tubular (CFSST) stub column, three square CFSST stub columns and nine CFRP confined square CFSST stub columns were tested under axial compression. The test parameters included the number of CFRP sheet layers and the thickness of the stainless steel tube. The test results showed that failure modes of all CFRP confined square CFSST stub columns were the fracture of CFRP sheets and the outward local buckling of the stainless steel tube at the chamfering. The typical load-displacement curves of the tested columns exhibited four stages, i.e., elastic stage, elastoplastic stage, descending stage and residual stage. CFRP sheets could restrain the local buckling of CFSST, and improve the ultimate bearing capacity and the ductility index of the columns. With the increase in the number of CFRP sheet layers and the wall thickness of the stainless steel tube, the bearing capacity of the column increased linearly. Based on the twin-shear unified strength theory, a calculation method of the ultimate bearing capacity of the square CFSST stub column was proposed. Besides, through the superposition method and regression analysis, two simplified methods to predict the ultimate bearing capacity of CFRP confined square CFSST stub column under axial compression were obtained.
引用
收藏
页数:13
相关论文
共 61 条
[1]  
[Anonymous], 2004, GBT33542014
[2]  
[Anonymous], 2019, The Chinese National Standard GB/T 50081
[3]  
[Anonymous], 2010, DBJ/T13-51-2010
[4]  
[Anonymous], 2004, Bridge Design, Part 6: Steel and Composite Construction
[5]  
[Anonymous], 2005, Design of steel structures-Part 1.1: General rules and rules for buildings. EN 1993-1-1:2005
[6]  
[Anonymous], 2005, 36005 ANSI AISC
[7]   Compressive strength of concrete-filled stainless steel tube stub columns [J].
Dai, Peng ;
Yang, Lu ;
Wang, Jie ;
Zhou, Yuhang .
ENGINEERING STRUCTURES, 2020, 205
[8]   Confinement coefficient of concrete-filled square stainless steel tubular stub columns [J].
Ding, Fa-xing ;
Yin, Yi-xiang ;
Wang, Liping ;
Yu, Yujie ;
Luo, Liang ;
Yu, Zhi-wu .
STEEL AND COMPOSITE STRUCTURES, 2019, 30 (04) :337-350
[9]   Behaviour of CFRP-confined concrete-filled circular steel tube stub columns under axial loading [J].
Ding, Fa-xing ;
Lu, De-ren ;
Bai, Yu ;
Gong, Yong-zhi ;
Yu, Zhi-wu ;
Ni, Ming ;
Li, Wei .
THIN-WALLED STRUCTURES, 2018, 125 :107-118
[10]   Structural Performance of Eccentric Ferrocement Reinforced Concrete Columns [J].
Erfan, Abeer M. ;
Ahmed, Hossam H. ;
Mina, Bishoy A. ;
El-Sayed, Taha A. .
NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2019, 11 (09) :1213-1225