O-Ring Attachments on One-Piece Mini Dental implants: In Vitro Analysis of Retention Force Reproducibility Using Different Pristine Matrix-O-Ring Combinations

被引:2
作者
Abou-Ayash, Samir [1 ,6 ]
Schimmel, Martin [2 ,3 ]
Worni, Andreas
Enkling, Norbert [4 ,5 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Sect Digital lmplant & Reconstruct Dent, Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[3] Univ Geneva, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[4] Univ Bern, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[5] Univ Bonn, Dept Prosthodont Preclin Educ & Dent Mat Sci, Bonn, Germany
[6] Gerodontol Univ Bern, Dept Reconstruct Dent, Freiburgstrasse 7, CH-3010 Bern, Switzerland
关键词
OVERDENTURES; SURVIVAL; SUCCESS;
D O I
10.11607/ijp.7055
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To analyze the influence of pristine matrix and O-ring dimensions on retention force and its reproducibility in single one-piece mini dental implants (MDIs) with ball patrices under in vitro conditions. Materials and Methods: Three different matrix/O-ring combinations (MH1, MH2, and MH3) were evaluated (n = 50 measurements each) on 1.8-mm-diameter implants. The matrices were manually mounted on the implants and subsequently removed in a vertical linear manner using a metal pin with two strain gauges, which recorded the maximum force during disconnection. The O-rings were exchanged after five disconnections, and the mean retention force was calculated, resulting in a total of 50 values for each matrix/O-ring combination. Mean and SD retention forces with 95% CI were calculated. ANOVA was used to test the global difference, and post hoc pairwise comparisons were subsequently applied. The leve) of significance was set at P < .05. Results: ANOVA (global P < .0001) and pairwise comparisons (all P < .001) demonstrated statistically significant differences between the three different matrix/O-ring combinations with mean values of 5.18 N (MH 1), 6.73 (MH 2), and 9.08 (MH 3). Within each combination, retention force variations of > 1 N could not be demonstrated; ie, by exchanging O-rings, a similar retention force can be reestablished. Condusion: Matrix and O-ring dimensions have a significant influence on retention forces in one-piece MDIs. Pristine O-rings demonstrated highly reproducible initial retention forces in all matrices. lntJ Prosthodont 2023;36:59-62. doi: 10.11607/ijp.7055
引用
收藏
页码:59 / 62
页数:4
相关论文
共 23 条
  • [1] Evolution of in vivo assessed retention forces in one-piece mini dental implant-retained mandibular overdentures: 5-Year follow-up of a prospective clinical trial
    Abou-Ayash, Samir
    Enkling, Norbert
    Srinivasan, Murali
    Haueter, Marius
    Worni, Andreas
    Schimmel, Martin
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 968 - 976
  • [2] AI-Nawas B, 2014, EUR J ORAL IMPLANTOL, V7, P5219
  • [3] Alsabeeha N, 2010, INT J PROSTHODONT, V23, P160
  • [4] Boulos Paul J., 2018, General Dentistry, V66, P41
  • [5] Resistance to Wear of Four Matrices with Ball Attachments for Implant Overdentures: A Fatigue Study
    Branchi, Roberto
    Vangi, Dario
    Virga, Antonio
    Guertin, Genevieve
    Fazi, Giovanni
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (08): : 31 - 36
  • [6] Buser R, 2018, FORUM IMPLANTOLOGICU, V14, P130
  • [7] FREEDOM OF ROTATION OF SELECTED OVERDENTURE ATTACHMENTS: AN IN VITRO STUDY
    Chen, I-Chieh
    Brudvik, James S.
    Mancl, Lloyd A.
    Rubenstein, Jeffrey E.
    Chitswe, Kinsey
    Raigrodski, Ariel J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (02) : 78 - 86
  • [8] Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations
    Choi, Jae-Won
    Bae, Ji-Hyeon
    Jeong, Chang-Mo
    Huh, Jung-Bo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (05) : 628 - 635
  • [9] Retentive Properties of O-Ring and Locator Attachments for Implant-Retained Maxillary Overdentures: An In Vitro Study
    ELsyad, Moustafa Abdou
    Elhaddad, Abdelsalam Amohamed
    Khirallah, Ahmed Samir
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (06): : 568 - 576
  • [10] Clinical outcomes and bone-level alterations around one-piece mini dental implants retaining mandibular overdentures: 5-year follow-up of a prospective cohort study
    Enkling, Norbert
    Moazzin, Rim
    Geers, Gregor
    Kokoschka, Stephanie
    Abou-Ayash, Samir
    Schimmel, Martin
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (06) : 549 - 556