High Impedance Fault Models for Overhead Distribution Networks: A Review and Comparison with MV Lab Experiments

被引:3
作者
Huaquisaca Paye, Juan Carlos [1 ,2 ]
Vieira, Joao Paulo A. [1 ]
Tabora, Jonathan Munoz [1 ,3 ]
Leao, Andre P. [1 ]
Cordeiro, Murillo Augusto M. [1 ]
Junior, Ghendy C. [4 ]
Morais, Adriano P. de [4 ]
Farias, Patrick E. [5 ]
机构
[1] Fed Univ Para, Inst Technol, Elect Engn Fac, BR-66075110 Belem, Brazil
[2] Publ Univ El Alto UPEA, Elect Engn Dept, La Paz 00591, Bolivia
[3] Natl Autonomous Univ Honduras UNAH, Elect Engn Dept, Tegucigalpa 04001, Honduras
[4] Univ Fed Santa Maria, Dept Elect Engn, BR-97105900 Santa Maria, Brazil
[5] Fed Inst Rio Grande do Sul, Fed Inst Educ Sci & Technol, BR-95174274 Farroupilhas, Brazil
关键词
high impedance faults (HIFs); HIF models; overhead distribution networks (ODN); lab experiment; DISTRIBUTION-SYSTEMS; WAVELET TRANSFORM; RELAY ALGORITHM; LOCATION; METHODOLOGY; SIMULATION;
D O I
10.3390/en17051125
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Detecting and locating high impedance faults (HIF) in overhead distribution networks (ODN) remains one of the biggest challenges for manufacturers and researchers due to the complexity of this phenomenon, where the electrical current magnitude is similar to that of the loads. To simulate HIF, the selection of the HIF model is important, because it has to correctly reproduce the characteristics of this phenomenon, so that it does not negatively influence the simulations results. Therefore, HIF models play a fundamental role in proposing solutions and validating the effectiveness of the proposed methods to detect and localize HIF in ODN. This paper presents a systematic review of HIF models. It is intended to facilitate the selection of the HIF model to be considered. The models are validated based on experimental data from medium voltage (MV) laboratories, specifically, recorded waveforms from two HIF tests conducted in an MV lab were analyzed and compared with three established HIF models. The efficacy of these models was assessed against MV lab test data to ensure a precise representation of both transient and steady-state conditions for fault conductance and current waveforms. The findings show that the two nonlinear resistor models better approximate the waveforms obtained in the experimental tests performed in this study.
引用
收藏
页数:22
相关论文
共 87 条
[1]  
Adamiak M., High Impedance Fault Detection on Distribution Feeders
[2]   High-Impedance Fault Diagnosis: A Review [J].
Aljohani, Abdulaziz ;
Habiballah, Ibrahim .
ENERGIES, 2020, 13 (23)
[3]  
Aucoin B.M., 1982, Power Engineering Review, IEEE, VPER-2, P46, DOI [10.1109/MPER.1982.5521003, DOI 10.1109/MPER.1982.5521003]
[4]   High impedance fault detection implementation issues [J].
Aucoin, BM ;
Jones, RH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) :139-148
[5]  
Balser S.J., Detection of High Impedance Faults
[6]   High impedance fault detection methodology using wavelet transform and artificial neural networks [J].
Baqui, Ibrahem ;
Zamora, Inmaculada ;
Mazon, Javier ;
Buigues, Garikoitz .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) :1325-1333
[7]   Practical high-impedance fault detection on distribution feeders [J].
Benner, CL ;
Russell, BD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (03) :635-640
[8]   DETECTION OF HIGH IMPEDANCE FAULTS ON MULTI-GROUNDED PRIMARY DISTRIBUTION-SYSTEMS [J].
CARR, J .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04) :2008-2016
[9]  
Cassie A.M., 1939, Theorie Nouvelle des Arcs de Rupture et de la Rigidite des Circuits, P588
[10]  
Cordeiro M.A.M., 2019, P 13 LATIN AM C ELEC