Assessing the combined effects of local climate and mounting configuration on the electrical and thermal performance of photovoltaic systems. Application to the greater Sydney area

被引:1
作者
Boccalatte, Alessia [1 ,3 ]
Thebault, Martin [1 ]
Paolini, Riccardo [2 ]
Fossa, Marco [3 ]
Ramousse, Julien [1 ]
Menezo, Christophe [1 ]
Santamouris, Mattheos [2 ]
机构
[1] Univ Savoie Mont Blanc, LOCIE, CNRS, UMR5271, F-73376 Le Bourget Du Lac, France
[2] Univ New South Wales UNSW, Fac Built Environm, Sydney, NSW 2052, Australia
[3] Univ Genoa, DIME Dept Mech Energy Management & Transportat En, I-16145 Genoa, Italy
关键词
Urban overheating; Photovoltaic (PV) system performance; Mounting configurations; Daytime convective flux; OPERATING TEMPERATURE; ENERGY EFFICIENCY; AIR-TEMPERATURE; SKY TEMPERATURE; HEAT-ISLAND; PV MODULES; IMPACT; PANELS; RELIABILITY; EXPERIENCE;
D O I
10.1016/j.renene.2023.119478
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Extremely high urban temperatures adversely affect photovoltaic (PV) system performance. Accurate PV cell temperature assessment relies on local weather conditions, exacerbated by urban overheating, often overlooked by inadequate temperature models and non-local data. This study investigates the electrical and thermal PV performance, considering mounting configurations and local conditions. Data from ten weather stations in Greater Sydney (NSW) during 2016-2017, including a hot summer, are used. The Sandia model is used to predict cell temperatures and power output for four mounting configurations, from open rack to building-integrated (BIPV). A PV thermal model is implemented to analyse daytime convection, crucial for understanding PV impact on local climate. Results show peak cell temperatures of 60 degrees C (open rack) to over 90 degrees C (BIPV), causing up to 50% power loss and 11% reduction in monthly performance ratio. Local climate variations impact PV energy output up to 6%, with mounting configuration effects up to 11%. Daytime convective flux averages 150-180 W/m2, peaking at 700 W/m2. Convective release varies up to 22% based on local climate, generally higher for open rack than close roof mounts, with potential reversals under low wind speed conditions. These findings can improve the knowledge of PV performances in urban areas facing extreme temperatures.
引用
收藏
页数:19
相关论文
共 96 条
  • [71] Increasing frequency, intensity and duration of observed global heatwaves and warm spells
    Perkins, S. E.
    Alexander, L. V.
    Nairn, J. R.
    [J]. GEOPHYSICAL RESEARCH LETTERS, 2012, 39
  • [72] Comparing photovoltaic and reflective shade surfaces in the urban environment: Effects on surface sensible heat flux and pedestrian thermal comfort
    Pham, Julie, V
    Baniassadi, Amir
    Brown, Kyle E.
    Heusinger, Jannik
    Sailor, David J.
    [J]. URBAN CLIMATE, 2019, 29
  • [73] Pokhrel Rabindra, 2020, Journal of Engineering for Sustainable Buildings and Cities, V1, DOI 10.1115/1.4045347
  • [74] Combining High-Resolution Land Use Data With Crowdsourced Air Temperature to Investigate Intra-Urban Microclimate
    Potgieter, Julia
    Nazarian, Negin
    Lipson, Mathew J.
    Hart, Melissa A.
    Ulpiani, Giulia
    Morrison, William
    Benjamin, Kit
    [J]. FRONTIERS IN ENVIRONMENTAL SCIENCE, 2021, 9
  • [75] Principe J.A., 2019, Int. Arch. Photogramm. Remote Sens. Spat. Inf. Sci. - ISPRS Arch., V42, P339, DOI [10.5194/isprs-archives-XLII-4-W19-339-2019, DOI 10.5194/ISPRS-ARCHIVES-XLII-4-W19-339-2019]
  • [76] REINDL DT, 1990, SOL ENERGY, V45, P1, DOI [10.1016/0038-092X(90)90060-P, 10.1016/0038-092X(91)90123-E]
  • [77] Ross R. G., 1976, INTERFACE DESIGN CON
  • [78] S.N. Laboratoraties, 2021, Pvlib _ python Documentation
  • [79] Photovoltaics in the built environment: A critical review
    Sailor, D. J.
    Anand, J.
    King, R. R.
    [J]. ENERGY AND BUILDINGS, 2021, 253
  • [80] Analyzing the heat island magnitude and characteristics in one hundred Asian and Australian cities and regions
    Santamouris, M.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 512 : 582 - 598