Exergy performance assessment of a novel air-cooled photovoltaic thermal collector with a double serpentine runner

被引:19
作者
Xie, Yujie [1 ]
Zhou, Jinzhi [1 ]
Bisengimana, Emmanuel [1 ]
Jiang, Fujian [1 ]
Ji, Wenhui [1 ]
Sun, Liangliang [1 ]
Zhao, Kaiming [1 ]
Yuan, Yanping [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu 610031, Peoples R China
关键词
Air-cooled PVT collector; A double serpentine runner; Baffle; Thermal and electrical efficiency; Exergy efficiency; Pressure drop; HEAT-TRANSFER; SOLAR COLLECTORS; PRESSURE-DROP; PVT SYSTEM; OPTIMIZATION; DESIGN; VENTILATION; BAFFLE; FINS; FLOW;
D O I
10.1016/j.applthermaleng.2023.121330
中图分类号
O414.1 [热力学];
学科分类号
摘要
Despite the various technologies are used in enhancing the air-cooled photovoltaic thermal (PVT) collector through ranging baffles on the chamber, it still leads to a greater pressure loss, resulting in increasing the energy consumption of the fan. This problem is addressed in this work by rearranging the baffle to form a double serpentine runner for improving heat transfer characteristic and reducing the pressure drop of the air in the structure of the serpentine runner. A CFD (Computational Fluid Dynamics) module has been carried out to analyze the collector performance and verified by the experiments. Influences of the structural and operating parameters are studied to optimize the performance of the PVT collector and the results indicated that: (a) Large flow stagnation zones may result from improperly arranged baffles, significantly affecting heat transfer and producing considerable pressure loss. And the recommended values of the structural parameters are given: baffle height is in the range of 75-95 mm, baffle number is in the range of 10-14, and baffle length is in the range of 700-800 mm. (b) although the thermal and electrical efficiency are improved with increasing flow rate, the exergy efficiency increases first and then reduces. The value of the air mass rate is suggested in the range of 0.02-0.03 kg/s. (c) the value ranges of the thermal, electrical, total, and exergy efficiency of the collector for Lasa in November can be 37.2-42.3 %, 11.3-12.5 %, 41.3-51.1 %, and 9.8-11.8 %. (d) comparing this collector with previous studies, the thermal and electrical efficiency of this collector is similar to other collectors, and the pressure drop is significantly lower.
引用
收藏
页数:17
相关论文
共 55 条
[1]   Simulation and Performance Analysis of Air-Type PVT Collector with Interspaced Baffle-PV Cell Design [J].
Ahn, Jong-Gwon ;
Yu, Ji-Suk ;
Boafo, Fred Edmond ;
Kim, Jin-Hee ;
Kim, Jun-Tae .
ENERGIES, 2021, 14 (17)
[2]  
[Anonymous], 2014, ANSI/ASHRAE 93 ERTA-2014.
[3]  
[Anonymous], 1974, Comput. Methods Appl. Mech. Eng., V3, P269
[4]  
[Anonymous], 2021, Test methods for solar collectors, Domestic National Standards State Administration for Market Regulation CN-GB
[5]   Energy and exergy analysis of different solar air collector systems with forced convection [J].
Bahrehmand, D. ;
Ameri, M. ;
Gholampour, M. .
RENEWABLE ENERGY, 2015, 83 :1119-1130
[6]  
Bailin X, 2011, Analysis on Heat Removal Factor and Thermal Performance of Integrated Flat-Plate Solar Collector, P76
[7]   Numerical and Experimental Study of the Impact of Key Parameters on a PVT Air Collector: Mass Flow Rate and Duct Depth [J].
Baklouti, Ismail ;
Driss, Zied .
JOURNAL OF THERMAL SCIENCE, 2021, 30 (05) :1625-1642
[8]  
Barker G, 2011, ASM INT C EN SUST
[9]  
Bolin X., 2011, Analysis on Heat Removal Factor And Thermal Performance Of Integrated Flat-Plate Solar Collector, P76
[10]  
Bolin X, 2012, Acta Energ. Solar Sin., V33, P1560