Diffusion weighted hyperpolarized 129Xe MRI of the lung with 2D and 3D (FLORET) spiral

被引:12
作者
Bdaiwi, Abdullah S. [1 ,2 ]
Willmering, Matthew M. [1 ]
Wang, Hui [3 ]
Cleveland, Zackary, I [1 ,2 ,4 ,5 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Ctr Pulm Imaging Res, Div Pulm Med, 3333 Burnet Ave,MLC 2021, Cincinnati, OH 45229 USA
[2] Univ Cincinnati, Dept Biomed Engn, Cincinnati, OH USA
[3] Philips Healthcare, Cincinnati, OH USA
[4] Univ Cincinnati, Dept Pediat, Cincinnati, OH USA
[5] Cincinnati Childrens Hosp, Imaging Res Ctr, Dept Radiol, Med Ctr, Cincinnati, OH USA
基金
美国国家卫生研究院;
关键词
ADC; diffusion; FLORET; GRE; hyperpolarized Xe-129; spiral; NUCLEAR-MAGNETIC-RESONANCE; HE-3; MORPHOMETRY; VENTILATION; HEALTHY; REPRODUCIBILITY; RATIONALE; SNR;
D O I
10.1002/mrm.29518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To enable efficient hyperpolarized Xe-129 diffusion imaging using 2D and 3D (Fermat Looped, ORthogonally Encoded Trajectories, FLORET) spiral sequences and demonstrate that Xe-129 ADCs obtained using these sequences are comparable to those obtained using a conventional, 2D gradient-recalled echo (GRE) sequence. Theory and Methods Diffusion-weighted Xe-129 MRI (b-values = 0, 7.5, 15 s/cm(2)) was performed in four healthy volunteers and one subject with lymphangioleiomyomatosis using slice-selective 2D-GRE (scan time = 15 s), slice-selective 2D-Spiral (4 s), and 3D-FLORET (16 s) sequences. Experimental SNRs from b-value = 0 images (SNR0EX$$ SNR{0}_{EX} $$) and mean ADC values were compared across sequences. In two healthy subjects, a second b = 0 image was acquired using the 2D-Spiral sequence to map flip angle and correct RF-induced, hyperpolarized signal decay at the voxel level, thus improving regional ADC estimates. Results Diffusion-weighted images from spiral sequences displayed image quality comparable to 2D-GRE and produced sufficient SNR0EX$$ SNR{0}_{EX} $$ (16.8 +/- 3.8 for 2D-GRE, 21.2 +/- 3.5 for 2D-Spiral, 20.4 +/- 3.5 for FLORET) to accurately calculate ADC. Whole-lung means and SDs of ADC obtained via spiral were not significantly different (P > 0.54) from those obtained via 2D-GRE. Finally, 2D-Spiral images were corrected for signal decay, which resulted in a whole-lung mean ADC decrease of similar to 15%, relative to uncorrected images. Conclusions Relative to GRE, efficient spiral sequences allow Xe-129 diffusion images to be acquired with isotropic lung coverage (3D), higher SNR$$ SNR $$(2D and 3D), and three-fold faster (2D) within a single breath-hold. In turn, shortened breath-holds enable flip-angle mapping, and thus, allow RF-induced signal decay to be corrected, increasing ADC accuracy.
引用
收藏
页码:1342 / 1356
页数:15
相关论文
共 53 条
  • [1] Assessment of lung development using hyperpolarized helium-3 diffusion MR imaging
    Altes, Talissa A.
    Mata, Jaime
    de lange, Eduard E.
    Brookeman, James R.
    Mugler, John P., III
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) : 1277 - 1283
  • [2] Improving hyperpolarized 129Xe ADC mapping in pediatric and adult lungs with uncertainty propagation
    Bdaiwi, Abdullah S.
    Niedbalski, Peter J.
    Hossain, Md M.
    Willmering, Matthew M.
    Walkup, Laura L.
    Wang, Hui
    Thomen, Robert P.
    Ruppert, Kai
    Woods, Jason C.
    Cleveland, Zackary I.
    [J]. NMR IN BIOMEDICINE, 2022, 35 (03)
  • [3] Brandon Zanette YF., 2020, ISMRM
  • [4] Brown R. W., 2014, MAGNETIC RESONANCE I, DOI DOI 10.1002/9781118633953
  • [5] Airway Microstructure in Idiopathic Pulmonary Fibrosis: Assessment at Hyperpolarized 3He Diffusion-weighted MRI
    Chan, Ho-Fong
    Weatherley, Nicholas D.
    Johns, Christopher S.
    Stewart, Neil J.
    Collier, Guilhem J.
    Bianchi, Stephen M.
    Wild, Jim M.
    [J]. RADIOLOGY, 2019, 291 (01) : 223 - 229
  • [6] 3D diffusion-weighted 129Xe MRI for whole lung morphometry
    Chan, Ho-Fung
    Stewart, Neil J.
    Norquay, Graham
    Collier, Guilhem J.
    Wild, Jim M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) : 2986 - 2995
  • [7] Costa M., 2021, ISMRM
  • [8] Hyperpolarized 3He apparent diffusion coefficient MRI of the lung:: Reproducibility and volume dependency in healthy volunteers and patients with emphysema
    Diaz, Sandra
    Casselbrant, Ingrid
    Piitulainen, Eeva
    Pettersson, Goran
    Magnusson, Peter
    Peterson, Barry
    Wollmer, Per
    Leander, Peter
    Ekberg, Olle
    Akeson, Per
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 763 - 770
  • [9] Fast dynamic ventilation MRI of hyperpolarized 129Xe using spiral imaging
    Doganay, Ozkan
    Matin, Tahreema N.
    Mcintyre, Anthony
    Burns, Brian
    Schulte, Rolf F.
    Gleeson, Fergus V.
    Bulte, Daniel
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2597 - 2606
  • [10] Detection of age-dependent changes in healthy adult lungs with diffusion-weighted 3He MRI
    Fain, SB
    Altes, TA
    Panth, SR
    Evans, MD
    Waters, B
    Mugler, JP
    Korosec, FR
    Grist, TM
    Silverman, M
    Salerno, M
    Owers-Bradley, J
    [J]. ACADEMIC RADIOLOGY, 2005, 12 (11) : 1385 - 1393