Deep learning approximation of attenuation maps for myocardial perfusion SPECT with an IQ.SPECT collimator

被引:0
|
作者
Huxohl, Tamino [1 ]
Patel, Gopesh [1 ]
Zabel, Reinhard [2 ]
Burchert, Wolfgang [1 ]
机构
[1] Univ Hosp Ruhr Univ Bochum, Inst Radiol Nucl Med & Mol Imaging, Heart & Diabet Ctr North Rhine Westphalia, Bad Oeynhausen, Germany
[2] Hosp Lippe, Inst Nucl Med, Lippe, Germany
来源
EJNMMI PHYSICS | 2023年 / 10卷 / 01期
关键词
Deep learning; SPECT; Myocardial perfusion imaging; Attenuation correction; PROCEDURAL GUIDELINES; COMPENSATION;
D O I
10.1186/s40658-023-00568-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The use of CT images for attenuation correction of myocardial perfusion imaging with single photon emission computer tomography (SPECT) increases diagnostic confidence. However, acquiring a CT image registered to a SPECT image is often not possible because most scanners are SPECT-only. It is possible to approximate attenuation maps using deep learning, but this has not yet been shown to work for a SPECT scanner with an IQ center dot SPECT collimator. This study investigates whether it is possible to approximate attenuation maps from non-attenuation-corrected (nAC) reconstructions acquired with a SPECT scanner equipped with an IQ center dot SPECT collimator. Methods: Attenuation maps and reconstructions were acquired retrospectively for 150 studies. A U-Net was trained to predict attenuation maps from nAC reconstructions using the conditional generative adversarial network framework. Predicted attenuation maps are compared to real attenuation maps using the normalized mean absolute error (NMAE). Attenuation-corrected reconstructions were computed, and the resulting polar maps were compared by pixel and by average perfusion per segment using the absolute percent error (APE). The training and evaluation code is available at https://gitlab.ub.uni-bielefeld.de/thuxohl/mu-map. Results: Predicted attenuation maps are similar to real attenuation maps, achieving an NMAE of 0.020 +/- 0.007. The same is true for polar maps generated from reconstructions with predicted attenuation maps compared to CT-based attenuation maps. Their pixel-wise absolute distance is 3.095 +/- 3.199, and the segment-wise APE is 1.155 +/- 0.769. Conclusions: It is feasible to approximate attenuation maps from nAC reconstructions acquired by a scanner with an IQ center dot SPECT collimator using deep learning.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Application of IQ.SPECT in Myocardial Perfusion Imaging: Comparison with conventional SPECT
    Jin, Xiaoxiao
    Wei, Hua
    Wu, Zhifang
    Liu, Jianzhong
    Hu, Guang
    Wang, Jin
    Li, Sijin
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [2] Creation and characterization of normal myocardial perfusion imaging databases using the IQ.SPECT system
    Okuda, Koichi
    Nakajima, Kenichi
    Matsuo, Shinro
    Kondo, Chisato
    Sarai, Masayoshi
    Horiguchi, Yoriko
    Konishi, Takahiro
    Onoguchi, Masahisa
    Shimizu, Takeshi
    Kinuya, Seigo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (04) : 1328 - 1337
  • [3] Comparison of MPI SPECT/CT scans acquired with LEHR collimator and reduced time IQ.SPECT system
    Ferreira, S.
    Begley, P.
    Jessop, M.
    Aldous, A.
    Eftychiou, N.
    Singh, N.
    Dizdarevic, S.
    Sousa, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S889 - S890
  • [4] Synthetic Attenuation Correction Maps for SPECT Imaging using Deep Learning: A Study on Myocardial Perfusion Imaging
    Namias, M.
    Prieto Canalejo, M. A.
    San Pedro, A. Palau
    Geronazzo, R.
    Minsky, D. M.
    Juarez Orozco, L. E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S270 - S271
  • [5] Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging
    Canalejo, Mariana Andrea Prieto
    Pedro, Aley Palau San
    Geronazzo, Ricardo
    Minsky, Daniel Mauricio
    Juarez-Orozco, Luis Eduardo
    Namias, Mauro
    DIAGNOSTICS, 2023, 13 (13)
  • [6] The Value of Semiquantitative Analysis in Myocardial Perfusion Imaging using Multifocal Collimator SPECT/CT: IQ-SPECT
    Trogrlic, M.
    Medvedec, M.
    Tezak, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S511 - S512
  • [7] Deep learning-based attenuation map generation for myocardial perfusion SPECT
    Shi, Luyao
    Onofrey, John A.
    Liu, Hui
    Liu, Yi-Hwa
    Liu, Chi
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (10) : 2383 - 2395
  • [8] Deep learning-based attenuation map generation for myocardial perfusion SPECT
    Luyao Shi
    John A. Onofrey
    Hui Liu
    Yi-Hwa Liu
    Chi Liu
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 2383 - 2395
  • [9] Comparing the Impact of SPECT and IQ SPECT Cardiac Images on Myocardial Perfusion
    Uitham, R.
    Willemsen, A.
    Koole, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S230 - S230
  • [10] Tomographic Performance Characteristics of the IQ.SPECT System
    Rajaram, Ramya
    Bhattacharya, Manojeet
    Ding, Xinhong
    Malmin, Ron
    Rempel, Trudy D.
    Vija, A. Hans
    Zeintl, Johannes
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2451 - 2456