A three-dimensional composite film-modified electrode based on polyoxometalates and ionic liquid-decorated carbon nanotubes for the determination of L-tyrosine in food

被引:2
|
作者
Wang, Ying [1 ]
Jiao, Jia [1 ,2 ]
Chu, Mingyue [1 ]
Jin, Zhongxin [1 ]
Liu, Yikun [1 ]
Song, Daozheng [1 ]
Yu, Ting-Ting [3 ]
Yang, Guixin [1 ]
Wang, Yingji [4 ]
Ma, Huiyuan [1 ]
Pang, Haijun [1 ]
Wang, Xinming [1 ]
机构
[1] Harbin Univ Sci & Technol, Sch Mat Sci & Chem Engn, Harbin 150040, Peoples R China
[2] Harbin Inst Technol, Sch Life Sci & Technol, Harbin 150040, Peoples R China
[3] Harbin Inst Petr, Coll Chem Engn, Harbin 150028, Peoples R China
[4] Harbin Med Univ, Coll Pharm, Harbin 150081, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical sensor; Cyclic voltammetry; Ionic liquid; Polyoxometalates; Layer-by-layer; L-tyrosine; ASCORBIC-ACID; URIC-ACID; NANOCOMPOSITE; NANOPARTICLES; PARACETAMOL; EPINEPHRINE; SURFACE; SERUM;
D O I
10.1007/s00604-023-05967-w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A stable and innovative composite film-modified electrode based on Dawson polyoxometalates H8P2Mo16V2O62 (P2Mo16V2) and ionic liquid (BMIMBr)-decorated carbon nanotubes, annotated as PEI/(P2Mo16V2/BMIMBr-CNTs)(8), has been constructed by using the layer-by-layer self-assembly (LBL) method for the determination of L-tyrosine. The combination of three active components not only offers higher conductivity to facilitate rapid electron transfer, but also avoids the accumulation of P2Mo16V2 to expand the contact area and increase the reactive active sites. The modified electrode exhibits outstanding sensing performance for determination of Tyr with wide linear determination range of 5.8x10(-7) M similar to 1.2x10(-4) M, low determination limit of 1.7x10(-7)M (S/N=3), high selectivity for common interferences, and excellent stability at the potential of +0.78 V (vs. Ag/AgCl (3 M KCl)). The relative standard deviation (RSD) of 4.3% for five groups of parallel experiments shows the satisfactory repeatability of PEI/(P2Mo16V2/BMIMBr-CNTs)(8). In addition, for determination of Tyr, the PEI/(P2Mo16V2/BMIMBr-CNTs)(8) shows good recoveries of 98.8-99.8% in meat floss, which can be feasible in practical application.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Voltammetric myoglobin sensor based on a glassy carbon electrode modified with a composite film consisting of carbon nanotubes and a molecularly imprinted polymerized ionic liquid
    Wang, Yanying
    Han, Miao
    Ye, Xiaoxue
    Wu, Kangbing
    Wu, Tsunghsueh
    Li, Chunya
    MICROCHIMICA ACTA, 2017, 184 (01) : 195 - 202
  • [22] Amperometric Immunosensor for Myeloperoxidase in Human Serum Based on a Multi-wall Carbon Nanotubes-Ionic Liquid-Cerium Dioxide Film-modified Electrode
    Lu, Lingsong
    Liu, Bei
    Liu, Chenggui
    Xie, Guoming
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (11) : 3259 - 3264
  • [23] Platinum nanoparticles decorated multiwalled carbon nanotubes - Ionic liquid composite film coated glassy carbon electrodes for sensitive determination of theophylline
    Liu, Liqin
    Xiao, Fei
    Li, Jiangwen
    Wu, Weibing
    Zhao, Faqiong
    Zeng, Baizhao
    ELECTROANALYSIS, 2008, 20 (11) : 1194 - 1199
  • [24] Direct electrochemistry of adenine on multiwalled carbon nanotube-ionic liquid composite film modified carbon paste electrode and its determination in DNA
    Arvand, M.
    Niazi, A.
    Mazhabi, R. Motaghed
    Biparva, P.
    JOURNAL OF MOLECULAR LIQUIDS, 2012, 173 : 1 - 7
  • [25] A sensitive electrochemical sensor based on aluminium doped copper selenide nanoparticles-modified screen printed carbon electrode for determination of L-tyrosine in pharmaceutical samples
    Murtada, Khaled
    Salghi, Rachid
    Rios, Angel
    Zougagh, Mohammed
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 874
  • [26] Electrocatalytic Oxidation of Ascorbic Acid on Quaternized Carbon Nanotubes/Ionic Liquid-Polyaniline Composite Film Modified Glassy Carbon Electrode
    Xi, Lingling
    Zhu, Zuoyi
    Wang, Fengli
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (06) : H327 - H334
  • [27] Electrochemical Biosensor Based on Carbon Ionic Liquid Electrode Modified with Nafion/Hemoglobin/DNA Composite Film
    Sun, Wei
    Wang, Yan
    Li, Xiaoqing
    Wu, Jie
    Zhan, Tianrong
    Jiao, Kui
    ELECTROANALYSIS, 2009, 21 (22) : 2454 - 2460
  • [28] Electrochemical deoxyribonucleic acid biosensor based on the self-assembly film with nanogold decorated on ionic liquid modified carbon paste electrode
    Gao, Hongwei
    Qi, Xiaowei
    Chen, Ying
    Sun, Wei
    ANALYTICA CHIMICA ACTA, 2011, 704 (1-2) : 133 - 138
  • [29] Fabrication of poly(orthanilic acid)–multiwalled carbon nanotubes composite film-modified glassy carbon electrode and its use for the simultaneous determination of uric acid and dopamine in the presence of ascorbic acid
    Lei Zhang
    Zhige Shi
    Qiuhua Lang
    Journal of Solid State Electrochemistry, 2011, 15 : 801 - 809
  • [30] Fabrication of poly(orthanilic acid)-multiwalled carbon nanotubes composite film-modified glassy carbon electrode and its use for the simultaneous determination of uric acid and dopamine in the presence of ascorbic acid
    Zhang, Lei
    Shi, Zhige
    Lang, Qiuhua
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (04) : 801 - 809