Effects of Structural Size on Postearthquake Fire Resistance of HSS-CHS-SHS T-Joints under Nonuniform Elevated Temperatures

被引:0
|
作者
Xu, Jixiang [1 ]
Tian, Fang [1 ]
Han, Jianping [1 ]
机构
[1] Lanzhou Univ Tech, Sch Civil Engn, Lanzhou 730050, Gansu, Peoples R China
基金
中国国家自然科学基金;
关键词
High-strength steel (HSS); HSS-CHS-SHS T-joints; Postearthquake failure mechanism; Gradient temperature; Theoretical modeling of bearing capacity; HIGH-STRENGTH STEEL; MECHANICAL-PROPERTIES; TUBULAR JOINTS; HYSTERETIC BEHAVIOR; LONGITUDINAL PLATE; POSTFIRE BEHAVIOR; DESIGN;
D O I
10.1061/JSENDH.STENG-12944
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Limited research has been conducted on the fire resistance of high-strength steel (HSS) T-joints after an earthquake. The aim of this study is to assess postearthquake fire resistance and determine the optimal design dimensions of HSS-circular hollow sections-square hollow sections (CHS-SHS) T-joints considering the nonuniform temperature field effect through parameter analysis. The computational models of HSS T-joints developed in this study were validated against existing test results. Twenty four computational models related to HSS-CHS-SHS T-joints were established using the finite element software ANSYS; further, a sequential temperature-displacement analysis method was used to perform a parameter study. Subsequently, parameter analysis was conducted on HSS-CHS-SHS T-joints by varying parameters such as chord-width-to-thickness ratio (gamma), brace-to-chord-thickness radio (tau), brace-to-chord-width ratio (alpha), chord-length-to-height ratio (beta), and damage variable (D similar to). The results indicate that the failure of HSS-CHS-SHS T-joints is attributed to plasticization of the chord surface, and that parameters alpha and D similar to have a significant influence on the postearthquake failure mechanism and catastrophic process. Moreover, an empirical theoretical model for determining the bearing capacity of HSS-CHS-SHS T-joints after exposure to fire is proposed and validated. The HSS-CHS-SHS T-joint is widely used in offshore platforms, building frames, transmission towers, etc. Secondary fires occur frequently after an earthquake, which typically cause huge casualties and economic losses. Since earthquakes may produce residual stress and deformation in HSS-CHS-SHS T-joints, the failure mechanism of HSS-CHS-SHS T-joints under fire cannot be used to accurately evaluate their reliability and safety under a postearthquake fire. Thereby, the investigation of this study can provide valuable reference for design, repair, and reinforcement of HSS-CHS-SHS T-joints.
引用
收藏
页数:17
相关论文
共 6 条
  • [1] Fire resistance of reinforced SHS T-joints considering gradient temperature effect under post-earthquake fire
    Xu, Jixiang
    Jiang, Wang
    Han, Jianping
    Wang, Jianjun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 191
  • [2] Fire resistance behavior of earthquake-damaged tubular T-joints at elevated temperatures
    Xu, Jixiang
    Yang, Longlong
    Han, Jianping
    Han, Zhaolong
    Tu, Jiahuang
    Li, Zhanjie
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 159 : 176 - 188
  • [3] Structural Behavior of CHS T-Joints Subjected to Static In-Plane Bending in Fire Conditions
    Fung, T. C.
    Tan, K. H.
    Nguyen, M. P.
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (03)
  • [4] Effects of structure size on post-earthquake fire resistance of CCBCC joints at non-uniform elevated temperatures
    Xu, Jixiang
    Sang, Shengtao
    Han, Jianping
    STRUCTURES, 2023, 58
  • [5] Numerical models and parametric study on ultimate strength of CHS T-joints subjected to brace axial compression under fire condition
    Nguyen, M. P.
    Tan, K. H.
    Fung, T. C.
    TUBULAR STRUCTURES XIII, 2010, : 733 - 740
  • [6] Fire resistance of thin-walled tubular T-joints with internal ring stiffeners under post-earthquake fire
    Xu, Jixiang
    Tong, Yige
    Han, Jianping
    Han, Zhaolong
    Li, Zhanjie
    THIN-WALLED STRUCTURES, 2019, 145