Lumen-apposing metal stents versus traditional self-expanding metal stents for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a systematic review and meta-analysis

被引:3
作者
Tian, Yong [1 ,2 ]
Yin, Changjie [3 ]
Ma, Yihan [1 ]
Fu, Guochuan [1 ]
Liu, Rui [2 ]
Ran, Hongmei [1 ]
Pan, Tao [1 ]
Xiao, Yang [2 ]
Wen, Xudong [1 ]
机构
[1] Chengdu Univ Tradit Chinese Med, Chengdu Peoples Hosp 1, Dept Gastroenterol, Chengdu, Sichuan, Peoples R China
[2] Chengdu Univ Tradit Chinese Med, Clin Med Coll, Chengdu, Sichuan, Peoples R China
[3] Gen Hosp Western Theater Command, Peoples Liberat Army, Chengdu, Sichuan, Peoples R China
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2023年 / 38卷 / 2期
关键词
Lumen-apposing metal stents; Self-expanding metal stents; Endoscopic ultrasound; Pancreatic fluid collections; Meta-analysis; BILIARY STENTS; NECROTIZING PANCREATITIS; PLASTIC STENTS; OUTCOMES; NECROSIS; SAFETY; MANAGEMENT; EFFICACY;
D O I
10.1007/s00464-023-10636-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Endoscopic drainage has become the preferred treatment for pancreatic fluid collections (PFCs). There is still a lack of reliable evidence to prove which metal stent is the best choice for endoscopic ultrasound (EUS)-guided drainage of PFCs. In this study, we aimed to evaluate the efficacy and safety of lumen-apposing metal stents (LAMS) compared to traditional self-expanding metal stents (SEMS) in meta-analysis.Methods We systematically searched PubMed, Embase, Web of Science, and Cochrane Library up to July 15, 2023. Relevant publications that compared LAMS with traditional SEMS for drainage of patients' PFCs under EUS-guidance were included. This meta-analysis assessed endpoints using Review Manager 5.3 and Stata 14.0 statistical software.Result Nine citations comprising 707 patients with PFCs were included. The clinical success rate of LAMS tended to be higher than that of SEMS (RR = 1.07, 95%CI [1.00, 1.15], P = 0.05). LAMS had a lower technical success rate (RR = 0.97, 95%CI [0.94, 0.99], P = 0.02) and faster procedure time (minutes) (MD = - 24.29, 95%CI [- 25.59, - 22.99], P < 0.00001) compared to SEMS. In addition, LAMS had fewer overall adverse events (RR = 0.64, 95%CI [0.48, 0.87], P = 0.004). For specific adverse events, LAMS had fewer migration (RR = 0.37, 95%CI [0.19, 0.72], P = 0.003), occlusion (RR = 0.43, 95%CI [0.22, 0.82], P = 0.01) and infection (RR = 0.38, 95%CI [0.20, 0.70], P = 0.002). There was no significant difference in bleeding and perforation between the two stents. For hospital stay (days), LAMS group was similar to SEMS group (MD = - 3.34, 95%CI [- 7.71, - 1.03], P = 0.13). Regarding recurrence, LAMS group was fewer than SEMS group (RR = 0.41, 95%CI [0.21, 0.78], P = 0.007).Conclusion Compared to traditional SEMS, LAMS has a higher clinical success rate, faster procedure time, fewer adverse events, similar hospital stay and lower recurrence rate in EUS-guided drainage of PFCs. LAMS is a good choice with a high technical success rate over 95%, and using a shorter length or "one-step" operation can further improve it. Richer placement experience is required for LAMS placement under EUS-guidance.
引用
收藏
页码:586 / 596
页数:11
相关论文
共 59 条
[1]   Lumen-apposing-metal stent misdeployment in endoscopic ultrasound-guided drainages: A systematic review focusing on issues and rescue management [J].
Armellini, Elia ;
Metelli, Flavio ;
Anderloni, Andrea ;
Cominardi, Anna ;
Aragona, Giovanni ;
Marini, Michele ;
Pace, Fabio .
WORLD JOURNAL OF GASTROENTEROLOGY, 2023, 29 (21) :3341-3361
[2]   Endoscopic management of acute necrotizing pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) evidence-based multidisciplinary guidelines [J].
Arvanitakis, Marianna ;
Dumonceau, Jean-Marc ;
Albert, Joerg ;
Badaoui, Abdenor ;
Bali, Maria Antonietta ;
Barthet, Marc ;
Besselink, Marc ;
Deviere, Jacques ;
Ferreira, Alexandre Oliveira ;
Gyokeres, Tibor ;
Hritz, Istvan ;
Hucl, Tomas ;
Milashka, Marianna ;
Papanikolaou, Ioannis S. ;
Poley, Jan-Werner ;
Seewald, Stefan ;
Vanbiervliet, Geoffroy ;
van Lienden, Krijn ;
van Santvoort, Hjalmar ;
Voermans, Rogier ;
Delhaye, Myriam ;
van Hooft, Jeanin .
ENDOSCOPY, 2018, 50 (05) :524-546
[3]   Lumen-apposing metal stents for endoscopic ultrasonography-guided interventions [J].
Bang, Ji Young ;
Varadarajulu, Shyam .
DIGESTIVE ENDOSCOPY, 2019, 31 (06) :619-626
[4]   Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial [J].
Bang, Ji Young ;
Navaneethan, Udayakumar ;
Hasan, Muhammad K. ;
Sutton, Bryce ;
Hawes, Robert ;
Varadarajulu, Shyam .
GUT, 2019, 68 (07) :1200-1209
[5]   Factors impacting treatment outcomes in the endoscopic management of walled-off pancreatic necrosis [J].
Bang, Ji Young ;
Wilcox, C. Mel ;
Trevino, Jessica ;
Ramesh, Jayapal ;
Peter, Shajan ;
Hasan, Muhammad ;
Hawes, Robert H. ;
Varadarajulu, Shyam .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 (11) :1725-1732
[6]   American Gastroenterological Association Clinical Practice Update: Management of Pancreatic Necrosis [J].
Baron, Todd H. ;
DiMaio, Christopher J. ;
Wang, Andrew Y. ;
Morgan, Katherine A. .
GASTROENTEROLOGY, 2020, 158 (01) :67-+
[7]  
Bekkali NLH, 2017, ENDOSC INT OPEN, V5, pE1189, DOI 10.1055/s-0043-120831
[8]   Analysis of pancreatic pseudocyst drainage procedural outcomes: a population based study [J].
Chawla, Amrita ;
Afridi, Faiz ;
Prasath, Vishnu ;
Chokshi, Ravi ;
Ahlawat, Sushil .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (01) :156-164
[9]   Lumen apposing metal stents are superior to plastic stents in pancreatic walled-off necrosis: a large international multicenter study [J].
Chen, Yen-I ;
Yang, Juliana ;
Friedland, Shai ;
Holmes, Ian ;
Law, Ryan ;
Hosmer, Amy ;
Stevens, Tyler ;
Franco, Matheus C. ;
Jang, Sunguk ;
Pawa, Rishi ;
Mathur, Nihar ;
Sejpal, Divyesh V. ;
Inamdar, Sumant ;
Trindade, Arvind J. ;
Nieto, Jose ;
Berzin, TylerM. ;
Sawhney, Mandeep ;
DeSimone, Michael L. ;
DiMaio, Christopher ;
Kumta, Nikhil A. ;
Gupta, Sanchit ;
Yachimski, Patrick ;
Anderloni, Andrea ;
Baron, Todd H. ;
James, Theodore W. ;
Jamil, Laith H. ;
Ona, Mel A. ;
Lo, Simon K. ;
Gaddam, Srinivas ;
Dollhopf, Markus ;
Bukhari, Majidah A. ;
Moran, Robert ;
Gutierrez, Olaya Brewer ;
Sanaei, Omid ;
Fayad, Lea ;
Ngamruengphong, Saowanee ;
Kumbhari, Vivek ;
Singh, Vikesh ;
Repici, Alessandro ;
Khashab, Mouen A. .
ENDOSCOPY INTERNATIONAL OPEN, 2019, 7 (03) :E347-E354
[10]   Cost-effectiveness analysis comparing lumen-apposing metal stents with plastic stents in the management of pancreatic walled-off necrosis [J].
Chen, Yen-I ;
Barkun, Alan N. ;
Adam, Viviane ;
Bai, Ge ;
Singh, Vikesh K. ;
Bukhari, Majidah ;
Gutierrez, Olaya Brewer ;
Elmunzer, B. Joseph ;
Moran, Robert ;
Fayad, Lea ;
El Zein, Mohamad ;
Kumbhari, Vivek ;
Repici, Alessandro ;
Khashab, Mouen A. .
GASTROINTESTINAL ENDOSCOPY, 2018, 88 (02) :267-+