Estimating Blood Pressure during Exercise with a Cuffless Sphygmomanometer

被引:2
作者
Hayashi, Kenta [1 ]
Maeda, Yuka [1 ]
Yoshimura, Takumi [2 ]
Huang, Ming [3 ]
Tamura, Toshiyo [4 ]
机构
[1] Univ Tsukuba, Inst Syst & Informat Engn, Tsukuba 3058577, Japan
[2] Tokyo Metropolitan Coll Ind Technol, Dept Med & Welf Engn, Tokyo 1168523, Japan
[3] Nagoya City Univ, Sch Data Sci, Nagoya 4678501, Japan
[4] Waseda Univ, Future Robot Org, Tokyo 1698050, Japan
关键词
blood pressure (BP); photoplethysmogram (PPG); skewness signal quality index (SSQI); feature extraction; long short-term memory (LSTM); bidirectional LSTM; exercise; PULSE TRANSIT-TIME;
D O I
10.3390/s23177399
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurately measuring blood pressure (BP) is essential for maintaining physiological health, which is commonly achieved using cuff-based sphygmomanometers. Several attempts have been made to develop cuffless sphygmomanometers. To increase their accuracy and long-term variability, machine learning methods can be applied for analyzing photoplethysmogram (PPG) signals. Here, we propose a method to estimate the BP during exercise using a cuffless device. The BP estimation process involved preprocessing signals, feature extraction, and machine learning techniques. To ensure the reliability of the signals extracted from the PPG, we employed the skewness signal quality index and the RReliefF algorithm for signal selection. Thereafter, the BP was estimated using the long short-term memory (LSTM)-based neural network. Seventeen young adult males participated in the experiments, undergoing a structured protocol composed of rest, exercise, and recovery for 20 min. Compared to the BP measured using a non-invasive voltage clamp-type continuous sphygmomanometer, that estimated by the proposed method exhibited a mean error of 0.32 & PLUSMN; 7.76 mmHg, which is equivalent to the accuracy of a cuff-based sphygmomanometer per regulatory standards. By enhancing patient comfort and improving healthcare outcomes, the proposed approach can revolutionize BP monitoring in various settings, including clinical, home, and sports environments.
引用
收藏
页数:14
相关论文
共 50 条
[31]   Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals [J].
Peng, Rong-Chao ;
Yan, Wen-Rong ;
Zhang, Ning-Ling ;
Lin, Wan-Hua ;
Zhou, Xiao-Lin ;
Zhang, Yuan-Ting .
SENSORS, 2015, 15 (09) :23653-23666
[32]   Using Impedance-plethysmography Technique for Cuffless Blood Pressure Measurement [J].
Liu, Shing-Hong ;
Cai, Guo-He ;
Cheng, Da-Chuan ;
Huang, Yung-Fa .
2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, :395-398
[33]   Causal inference based cuffless blood pressure estimation: A pilot study [J].
Liu, Lei ;
Zhang, Yuan-Ting ;
Wang, Wenyan ;
Chen, Yifan ;
Ding, Xiaorong .
COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 159
[34]   State-of-the-Art Analysis of Cuffless Methods for Blood Pressure Measurement [J].
Burbach, Simon ;
Brueck, Rainer ;
Keil, Alexander .
ADVANCES IN DIGITAL HEALTH AND MEDICAL BIOENGINEERING, VOL 1, EHB-2023, 2024, 109 :127-134
[35]   Calibration-Free Cuffless Blood Pressure Estimation Based on a Population With a Diverse Range of Age and Blood Pressure [J].
Yamanaka, Syunsuke ;
Morikawa, Koji ;
Morita, Hiroshi ;
Huh, Ji Young ;
Yamamura, Osamu .
FRONTIERS IN MEDICAL TECHNOLOGY, 2021, 3
[36]   Blood pressure-independent neurogenic effect on conductance and resistance vessels: a consideration for cuffless blood pressure measurement? [J].
Cox, James ;
Avolio, Alberto P. ;
Louka, Kyrollos ;
Shirbani, Fatemeh ;
Tan, Isabella ;
Butlin, Mark .
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, :7485-7488
[37]   Cuffless and Continuous Blood Pressure Estimation based on Multiple Regression Analysis [J].
Shen, Zixiao ;
Miao, Fen ;
Meng, Qinghan ;
Li, Ye .
2015 5TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND TECHNOLOGY (ICIST), 2015, :117-120
[38]   Cuffless Blood Pressure Estimation Using Calibrated Cardiovascular Dynamics in the Photoplethysmogram [J].
Samimi, Hamed ;
Dajani, Hilmi R. .
BIOENGINEERING-BASEL, 2022, 9 (09)
[39]   Dual-Stream CNN-LSTM Architecture for Cuffless Blood Pressure Estimation From PPG and ECG Signals: A PulseDB Study [J].
Shaikh, Mohd. Rizwan ;
Forouzanfar, Mohamad .
IEEE SENSORS JOURNAL, 2025, 25 (02) :4006-4014
[40]   Modeling of pulse transit time under the effects of hydrostatic pressure for cuffless blood pressure measurements [J].
Poon, Carmen C. Y. ;
Zhang, Yuan-Ting ;
Liu, Yinbo .
2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, :65-+