Quantitative Determination of Duloxetine Hydrochloride in Biological Samples of Blood Serum and Urine Using a Novel Potentiometric Sensor

被引:0
|
作者
Pourhakkkaka, Parvin [1 ]
Karimi, Mohammad Ali [1 ]
Tavallali, Hossein [1 ]
Ardakani, Mohammad Mazloum [2 ]
Pourhakkak, Pouran [1 ]
Rahimi, Eisa [1 ]
机构
[1] Payame Noor Univ, Dept Chem, Tehran 193954697, Iran
[2] Yazd Univ, Fac Sci, Dept Chem, Yazd 89195741, Iran
来源
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY | 2023年 / 15卷 / 03期
关键词
-Potentiometric sensor; Ion selective electrode; Duloxetine hydrochloride (DHCl); Duloxetine tetraphenylborate ion pair; Polyvinyl chloride (PVC);
D O I
10.22034/abec.2023.703903
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
this work, a potentiometric sensor was developed based on polyvinyl chloride (PVC), duloxetine tetraphenylborate ion pair, various plasticizers of dioctyl phthalate (DOP), benzyl butyl phthalate (BBP), di(2-ethylhexyl)phthalate (DEPH), tris(2-ethylhexyl) phosphate (TEPH), dibutyl butyl phosphonate (DBBPh), dibutyl phthalate (DBP), dioctyl sebacate (DOS), dibutyl sebacate (DBS), 2-nitrophenyl octyl ether (NPOE) and di-octyl phthalate (DOPH)) and THF as membrane solvent. The electrode responses at various contents of PVC and plasticizer were recorded to optimize their percentage compositions, and the best Nernst response (59.7) was obtained. The linear concentration range for this electrode made by optimal composition is 0.7 mu M to 0.1 M with a detection limit of 0.3 mu M. The response time of the ion -selective electrode based on the duloxetine-tetraphenylborate ion pair was determined. The effect of pH on the potential of duloxetine hydrochloride (DHCl) solution with a concentration of 1.0 mM was studied. Moreover, the performance of the prepared electrode was studied over two months to investigate the constructed membrane electrode's stability. The selectivity coefficients of the electrode for determination of DHCl in the presence of some ions and molecules including Na+, K+, Li+, Ni+, Mg2+, Cd2+, Zn2+, Mn2+, Fe2+, Ca2+, Cu2+, Co2+, Cr2+, ascorbic acid, D-fructose, sucrose, aspartic acid, L-H-histidine, dopamine, glucose, uric acid, propranolol, dexamethasone and melatonin were determined using a separate solution method (SSM) and an adapted potential method. The application of the proposed sensor to determine DHCl in two biological matrices, including blood serum and urine samples, was also investigated.
引用
收藏
页码:229 / 239
页数:11
相关论文
共 50 条
  • [1] A Novel Potentiometric Sensor for Determination of Tramadol Hydrochloride in Biological Samples
    Pourhakkak, Parvin
    Karimi, Mohammad Ali
    Pourhakkak, Pouran
    Ardakani, Mohammad Mazloum
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (02): : 191 - 200
  • [2] Development of Novel Potentiometric Sensors for Determination of Lidocaine Hydrochloride in Pharmaceutical Preparations, Serum and Urine Samples
    Ali, Tamer Awad
    Mohamed, Gehad Genidy
    Yahya, Ghada A.
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2017, 16 (02): : 498 - 512
  • [3] Potentiometric Sensor for Betahistine Determination in Pharmaceuticals, Urine and Blood Serum
    Ensafi, Ali A.
    Doozandeh, Fatemeh
    Allafchian, Ali R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2010, 21 (12) : 2246 - 2253
  • [4] A Novel Potentiometric Sensor for Determination of Tramadol Hydrochloride in Biological Samples (vol 14, pg 191, 2022)
    Pourhakkak, Parvin
    Karimi, Mohammad Ali
    Tavallali, Hossein
    Ardakani, Mohammad Mazloum
    Pourhakkak, Pouran
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (04): : 444 - 444
  • [5] A new potentiometric sensor for the determination of ketamine hydrochloride in ampoules and urine
    Abu Shawish, Hazem M.
    Saadeh, Salman M.
    Tamos, Hassan
    Abed-Almonem, Khalid I.
    Al Khalili, Osama
    ANALYTICAL METHODS, 2015, 7 (01) : 301 - 308
  • [6] Potentiometric Sensor for Furosemide Determination in Pharmaceuticals, Urine, Blood Serum and Bovine Milk
    Santini, Alberto O.
    Pezza, Helena R.
    Sequinel, Rodrigo
    Rufino, Jose L.
    Pezza, Leonardo
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (01) : 64 - 73
  • [7] Determination of Ofloxacin in Pharmaceuticals, Human Urine and Serum Using a Potentiometric Sensor
    Pimenta, A. M.
    Souto, M. R. S.
    Catarino, R. I. L.
    Leal, M. F. C.
    Lima, J. L. F. C.
    ELECTROANALYSIS, 2011, 23 (04) : 1013 - 1022
  • [8] Quantitative Determination of Duloxetine Hydrochloride in Pharmaceuticals and Urine Using Prepared Ion Selective Membrane Electrode
    Ammar, Reda A.
    Otaif, Haleema
    Al-Warthan, Abdulrhman
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (05): : 4369 - 4380
  • [9] Quantitative Determination of Duloxetine Hydrochloride in Pharmaceuticals and Urine Using Prepared Ion Selective Membrane Electrode
    Ammar, Reda A.
    Otaif, Haleema
    Al-Warthan, Abdulrhman
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2531 - 2542
  • [10] Development of new potentiometric sensors for the determination of proguanil hydrochloride in serum and urine
    Fatehy M.Abdel-Haleem
    Mohamed Saad
    Mohamed S.Rizk
    ChineseChemicalLetters, 2016, 27 (06) : 857 - 863