Surface trueness and precision of interim restorations fabricated by digital light processing and CAD-CAM milling systems

被引:5
作者
Thomas, Achsah Ann [1 ,2 ]
Daniel, Angleena Y. [1 ]
Gandhi, Nitasha [1 ]
Roy, Neethu [1 ]
Varghese, Kevin George [1 ]
Wadhwa, Samiksha [1 ]
Mathew, Jemin Elizabeth [1 ]
机构
[1] Christian Dent Coll, Dept Prosthodont & Crown & Bridge, Ludhiana, Punjab, India
[2] Christian Dent Coll, Dept Prosthodont & Crown & Bridge, Ludhiana 141008, Punjab, India
关键词
PROVISIONAL CROWNS; ACCURACY; FIT;
D O I
10.1016/j.prosdent.2023.07.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The development of digital dental technologies has enabled clinicians to use additive and subtractive manufacturing techniques to fabricate interim restorations. However, knowledge of the trueness and precision of such restorations fabricated using digital light processing (DLP) and computer-aided design and computer-aided manufacturing (CAD-CAM) methods is limited.Purpose. The purpose of this in vitro study was to assess and compare the accuracy of interim crowns fabricated using DLP and CAD-CAM methods.Material and methods. A typodont mandibular first molar was prepared for a ceramic crown, and a digital scan (Medit T500) was obtained to design interim crowns by using the CAD software program. The CAD data were designated as the reference data. A total of 20 crowns were fabricated by DLP and CAD-CAM technology. The fabricated interim crowns were further scanned using a laboratory scanner and were superimposed with the CAD data by using a 3-dimensional (3D) point cloud assessing software program (CloudCompare) for the evaluation of trueness and precision. Root mean square values (RMS) were obtained for the evaluation of discrepancies. The Student t test was used to compare data as the Shapiro-Wilk test confirmed the normal distribution.Results. RMS values for the trueness values of the external and intaglio surfaces of the 3D printed and milled interim crown displayed no statistically significant differences (P>.05). Precision for the external surface reported significance (P<.05), whereas that for the intaglio surface reported no significance (P>.05).Conclusions. The accuracy of interim crowns fabricated by using DLP was comparable with that of milled crowns. Both manufacturing systems produced a true reproduction of the CAD. As for precision, the external surface of the DLP interim crown was statistically different from that of the milled group as it relates to the CAD.
引用
收藏
页码:611.e1 / 611.e7
页数:7
相关论文
共 24 条
  • [11] Kang Wol, 2019, [Journal of Dental Hygiene Science, 치위생과학회지], V19, P238, DOI 10.17135/jdhs.2019.19.4.238
  • [12] Kim DY, 2017, J PROSTHET DENT, V117, P260, DOI 10.1016/j.prosdent.2016.07.007
  • [13] Lee WS, 2017, J ADV PROSTHODONT, V9, P265
  • [14] Fit of interim crowns fabricated using photopolymer-jetting 3D printing
    Mai, Hang-Nga
    Lee, Kyu-Bok
    Lee, Du-Hyeong
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02) : 208 - 215
  • [15] Fracture resistance of additive manufactured and milled implant-supported interim crowns
    Martin-Ortega, Nuria
    Sallorenzo, Alessandro
    Casajus, Javier
    Cervera, Alberto
    Revilla-Leon, Marta
    Gomez-Polo, Miguel
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02) : 267 - 274
  • [16] Mitteramskogler G., 2014, Addit. Manuf., V1-4, P110, DOI DOI 10.1016/J.ADDMA.2014.08.003
  • [17] A comparison of trueness and precision of 12 3D printers used in dentistry
    Nulty, Adam
    [J]. BDJ OPEN, 2022, 8 (01)
  • [18] Osman RB, 2017, INT J PROSTHODONT, V30, P182, DOI 10.11607/ijp.5117
  • [19] Workflow description of additively manufactured clear silicone indexes for injected provisional restorations: A novel technique
    Revilla-Leon, Marta
    Fountain, Joshua
    Piedra Cascon, Wenceslao
    Ozcan, Mutlu
    Zandinejad, Amirali
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (03) : 213 - 221
  • [20] Additive Manufacturing Technologies Used for Processing Polymers: Current Status and Potential Application in Prosthetic Dentistry
    Revilla-Leon, Marta
    Ozcan, Mutlu
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : 146 - 158