Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients

被引:7
|
作者
Leong, Sook Sam [1 ]
Jalalonmuhali, Maisarah [2 ]
Nazri, Mohammad
Ng, Kwan Hoong [2 ,4 ]
Vijayananthan, Anushya [5 ]
Hisham, Ranitha [6 ]
Wong, Jeannie Hsiu Ding [3 ]
机构
[1] Univ Teknol MARA, Fac Hlth Sci, Ctr Med Imaging Studies, Selangor, Malaysia
[2] Univ Malaya, Fac Med, Dept Med, Kuala Lumpur, Malaysia
[3] Univ Malaya, Fac Med, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[4] UCSI Univ, Fac Med & Hlth Sci, Port Dickson, Negeri Sembilan, Malaysia
[5] Univ Malaya Specialist Ctr, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[6] Univ Malaya, Univ Malaya Lib, Kuala Lumpur, Malaysia
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1144期
关键词
FORCE IMPULSE QUANTIFICATION; ALLOGRAFT FIBROSIS; ELASTICITY QUANTIFICATION; TISSUE ELASTICITY; KIDNEY; DISEASE; DIAGNOSIS; STIFFNESS; ARFI;
D O I
10.1259/bjr.20220288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Many studies have conflicting findings in using shear wave elastography (SWE) to assess renal fibrosis. This study reviews the use of SWE to evaluate pathological changes in native kidneys and renal allo-grafts. It also tries to elucidate the confounding factors and care taken to ensure the results are consistent and reliable. Methods: The review was carried out according to the Preferred Reporting Items for SystematicReviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus data-base up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk -of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.Results: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in system-atic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patientsConclusions: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE repro-ducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful. Advances in knowledge: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Quantifying Myocardial Contractility Changes Using Ultrasound-Based Shear Wave Elastography
    Vejdani-Jahromi, Maryam
    Freedman, Jenna
    Nagle, Matthew
    Kim, Young-Joong
    Trahey, Gregg E.
    Wolf, Patrick D.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (01) : 90 - 96
  • [32] Characterization of soft tissue tumours with ultrasound, shear wave elastography and MRI
    Winn, N.
    Baldwin, J.
    Cassar-Pullicino, V
    Cool, P.
    Ockendon, M.
    Tins, B.
    Jaremko, J. L.
    SKELETAL RADIOLOGY, 2020, 49 (06) : 869 - 881
  • [33] Defining the optimal technique for endoscopic ultrasound shear wave elastography: a combined benchtop and animal model study with comparison to transabdominal shear wave elastography
    Wang, Thomas J.
    Ryou, Marvin
    CLINICAL ENDOSCOPY, 2023, 56 (02) : 229 - 238
  • [34] ULTRASOUND AND POINT SHEAR WAVE ELASTOGRAPHY IN LIVERS OF PATIENTS WITH PRIMARY SCLEROSING CHOLANGITIS
    Mjelle, Anders Batman
    Mulabecirovic, Anesa
    Hausken, Trygve
    Havre, Roald Flesland
    Gilja, Odd Helge
    Vesterhus, Mette
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (09): : 2146 - 2155
  • [35] Clinical Application of Shear Wave Elastography With Shear Wave Dispersion Imaging in the Preoperative Evaluation of Hepatic Parenchyma in Patients With Liver Tumors
    Wang, Kun
    Zhang, Shuchen
    Zhou, Wenyan
    Wen, Li
    Zhang, Shanshan
    Yu, Dong
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (04) : 797 - 807
  • [36] Value of ultrasound shear wave elastography in the diagnosis of adenomyosis
    Acar, S.
    Millar, E.
    Mitkova, M.
    Mitkov, V.
    ULTRASOUND, 2016, 24 (04) : 205 - 213
  • [37] Evaluation of Main Lacrimal Gland through Shear-wave Ultrasound Elastography in Patients with Low Schirmer Value
    Yilmaz, Hakan
    Gunes, Irfan Botan
    CURRENT MEDICAL IMAGING, 2024, 20
  • [38] The evaluation of retrobulbar fat tissue in Graves' orbitopathy with shear-wave ultrasound elastography
    Gunes, Irfan Botan
    Yilmaz, Hakan
    Onal, Eda Demir
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [39] Testicular Evaluation Using Shear Wave Elastography (SWE) in Patients with Varicocele
    Baleato-Gonzalez, Sandra
    Osorio-Vazquez, Iria
    Flores-Rios, Enrique
    Santiago-Perez, Maria Isolina
    Laguna-Reyes, Juan Pablo
    Garcia-Figueiras, Roberto
    JOURNAL OF IMAGING, 2023, 9 (09)
  • [40] Value of Shear Wave Elastography for differentiating benign and malignant renal lesions
    Aydin, Sinem
    Yildiz, Seyma
    Turkmen, Ihsan
    Sharifov, Rasul
    Uysal, Omer
    Gucin, Zuhal
    Armagan, Abdullah
    Kocakoc, Ercan
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (01) : 21 - 26