Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients

被引:7
|
作者
Leong, Sook Sam [1 ]
Jalalonmuhali, Maisarah [2 ]
Nazri, Mohammad
Ng, Kwan Hoong [2 ,4 ]
Vijayananthan, Anushya [5 ]
Hisham, Ranitha [6 ]
Wong, Jeannie Hsiu Ding [3 ]
机构
[1] Univ Teknol MARA, Fac Hlth Sci, Ctr Med Imaging Studies, Selangor, Malaysia
[2] Univ Malaya, Fac Med, Dept Med, Kuala Lumpur, Malaysia
[3] Univ Malaya, Fac Med, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[4] UCSI Univ, Fac Med & Hlth Sci, Port Dickson, Negeri Sembilan, Malaysia
[5] Univ Malaya Specialist Ctr, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[6] Univ Malaya, Univ Malaya Lib, Kuala Lumpur, Malaysia
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1144期
关键词
FORCE IMPULSE QUANTIFICATION; ALLOGRAFT FIBROSIS; ELASTICITY QUANTIFICATION; TISSUE ELASTICITY; KIDNEY; DISEASE; DIAGNOSIS; STIFFNESS; ARFI;
D O I
10.1259/bjr.20220288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Many studies have conflicting findings in using shear wave elastography (SWE) to assess renal fibrosis. This study reviews the use of SWE to evaluate pathological changes in native kidneys and renal allo-grafts. It also tries to elucidate the confounding factors and care taken to ensure the results are consistent and reliable. Methods: The review was carried out according to the Preferred Reporting Items for SystematicReviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus data-base up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk -of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.Results: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in system-atic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patientsConclusions: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE repro-ducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful. Advances in knowledge: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Shear wave elastography evaluation of kidneys in children with familial mediterranean fever
    Ozmen, Z.
    Kasap, T.
    Aktas, F.
    Ozmen, Z. C.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (07) : 957 - 962
  • [22] An evaluation with shear wave elastography of kidney elasticity in patients with familial Mediterranean fever
    Kayali, Alperen
    Keles, Fatma Ozturk
    Seyfettin, Ayca
    Dirican, Emre
    Celik, Muhammed Murat
    JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (01) : 177 - 183
  • [23] NAFLD evaluation: Which is more appropriate, multislice computed tomography or ultrasound real-time shear wave elastography?
    Lei, Pinggui
    Jiao, Jun
    Li, Hong
    Wang, Pingxian
    Duan, Qinghong
    Liu, Jing
    Zhou, Shi
    Wei, Qian
    Wang, Xiaolin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (05) : 871 - 883
  • [24] Comparison of ultrasound shear wave elastography with magnetic resonance elastography and renal microvascular flow in the assessment of chronic renal allograft dysfunction
    Garcia, Stephan R. Marticorena
    Guo, Jing
    Duerr, Michael
    Denecke, Timm
    Hamm, Bernd
    Sack, Ingolf
    Fischer, Thomas
    ACTA RADIOLOGICA, 2018, 59 (09) : 1139 - 1145
  • [25] Evaluation of Diaphragm Thickness and Stiffness Using Ultrasound and Shear-Wave Elastography
    Sendur, Halit Nahit
    Cerit, Mahi Nur
    Sendur, Aylin Billur
    Oktar, Suna Ozhan
    Yucel, Cem
    ULTRASOUND QUARTERLY, 2022, 38 (01) : 89 - 93
  • [26] Point shear wave elastography of the liver in healthy adult cats
    Park, Saechol
    Choi, Jeongwoo
    Kim, Kyeonga
    Oh, Donghyun
    Yoon, Junghee
    Choi, Mincheol
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2021, 82 (04) : 286 - 291
  • [27] Shear Wave Elastography (SWE) for the Evaluation of Patients with Plantar Fasciitis
    Gatz, Matthias
    Bejder, Ljudmila
    Quack, Valentin
    Schrading, Simone
    Dirrichs, Timm
    Tingart, Markus
    Kuhl, Christiane
    Betsch, Marcel
    ACADEMIC RADIOLOGY, 2020, 27 (03) : 363 - 370
  • [28] Magnetic resonance elastography vs. point shear wave ultrasound elastography for the assessment of renal allograft dysfunction
    Kennedy, Paul
    Bane, Octavia
    Hectors, Stefanie J.
    Gordic, Sonja
    Berger, Mark
    Delaney, Veronica
    Salem, Fadi
    Lewis, Sara
    Menon, Madhav
    Taouli, Bachir
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
  • [29] Plane wave elastography: a frequency-domain ultrasound shear wave elastography approach
    Khodayi-mehr, Reza
    Urban, Matthew W.
    Zavlanos, Michael M.
    Aquino, Wilkins
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12):
  • [30] Ultrasound evaluation of stiffness and vascularity of renal parenchymal damage secondary to hydronephrosis in pediatric patients using shear wave elastography and superb microvascular imaging
    Gunay, Burak
    Solak, Serdar
    Ustabasioglu, Fethi Emre
    Kula, Osman
    Karabulut, Derya
    Tuncbilek, Nermin
    SONOGRAPHY, 2024, 11 (03) : 223 - 230