Applicability and usage of dose mapping/accumulation in radiotherapy

被引:31
|
作者
Murr, Martina [1 ]
Brock, Kristy K. [2 ,3 ]
Fusella, Marco [4 ]
Hardcastle, Nicholas [5 ,6 ]
Hussein, Mohammad [7 ]
Jameson, Michael G. [8 ]
Wahlstedt, Isak [9 ,10 ,11 ]
Yuen, Johnson [12 ,13 ,14 ]
McClelland, Jamie R. [15 ]
Osorio, Eliana Vasquez [16 ]
机构
[1] Univ Tubingen, Dept Radiat Oncol, Sect Biomed Phys, Tubingen, Germany
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
[4] Abano Terme Hosp, Dept Radiat Oncol, Abano Terme, Italy
[5] Univ Melbourne, Peter MacCallum Canc Ctr, Phys Sci, Melbourne, Vic, Australia
[6] Univ Melbourne, Sir Peter MacCallum Dept Oncol, Melbourne, Vic, Australia
[7] Natl Phys Lab, Metrol Med Phys Ctr, Teddington, Middx, England
[8] Univ New South Wales, Fac Med & Hlth, Sch Clin Med, GenesisCare New South Wales, Sydney, Australia
[9] Tech Univ Denmark, Dept Hlth Technol, Anker Engelunds Vej 1,Bygning 101A, DK-2800 Kongens Lyngby, Denmark
[10] Rigshosp RH, Copenhagen Univ Hosp, Ctr Canc & Organ Dis, Dept Oncol, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
[11] Copenhagen Univ Hosp Herlev & Gentofte HGH, Dept Oncol, Borgmester Ib Juuls Vej 7, DK-2730 Herlev, Denmark
[12] St George Hosp, Canc Care Ctr, Kogarah, NSW 2217, Australia
[13] Univ New South Wales, South Western Clin Sch, Sydney, NSW, Australia
[14] Ingham Inst Appl Med Res, Sydney, NSW, Australia
[15] UCL, Ctr Med Image Comp & Wellcome, EPSRC Ctr Intervent & Surg Sci, Dept Med Phys & Biomed Engn, London, England
[16] Univ Manchester, Div Canc Sci, Fac Biol Med & Hlth, Manchester M20 4BX, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Dose mapping; accumulation; Deformable image registration (DIR); DIR uncertainties; Impact of dose mapping uncertainties; Anatomical changes; accumulation landscape  (DMAL); DEFORMABLE IMAGE REGISTRATION; ADAPTIVE RADIATION-THERAPY; VOXEL-BASED ANALYSIS; NONRIGID REGISTRATION; ACCUMULATION; LUNG; HEAD; UNCERTAINTIES; MOTION; INFORMATION;
D O I
10.1016/j.radonc.2023.109527
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Dose mapping/accumulation (DMA) is a topic in radiotherapy (RT) for years, but has not yet found its widespread way into clinical RT routine. During the ESTRO Physics workshop 2021 on "commissioning and quality assurance of deformable image registration (DIR) for current and future RT applications ", we built a working group on DMA from which we present the results of our discussions in this article. Our aim in this manuscript is to shed light on the current situation of DMA in RT and to highlight the issues that hinder consciously integrating it into clinical RT routine.As a first outcome of our discussions, we present a scheme where representative RT use cases are posi-tioned, considering expected anatomical variations and the impact of dose mapping uncertainties on patient safety, which we have named the DMA landscape (DMAL). This tool is useful for future reference when DMA applications get closer to clinical day-to-day use.Secondly, we discussed current challenges, lightly touching on first-order effects (related to the impact of DIR uncertainties in dose mapping), and focusing in detail on second-order effects often dismissed in the current literature (as resampling and interpolation, quality assurance considerations, and radiobio-logical issues). Finally, we developed recommendations, and guidelines for vendors and users. Our main point include: Strive for context-driven DIR (by considering their impact on clinical decisions/judgements) rather than perfect DIR; be conscious of the limitations of the implemented DIR algorithm; and consider when dose mapping (with properly quantified uncertainties) is a better alternative than no mapping.(c) 2023 The Author(s). Published by Elsevier B.V. Radiotherapy and Oncology 182 (2023) 1-11 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:11
相关论文
共 50 条
  • [41] INTER-INDIVIDUAL ORGAN-DRIVEN CT REGISTRATION FOR DOSE MAPPING IN PROSTATE CANCER RADIOTHERAPY
    Drean, Gael
    Acosta, Oscar
    Simon, Antoine
    de Crevoisier, Renaud
    Haigron, Pascal
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 370 - 373
  • [42] Development of a multi-layer quality assurance program to evaluate the uncertainty of deformable dose accumulation in adaptive radiotherapy
    Zhong, Hualiang
    Garcia-Alvarez, Juan A.
    Kainz, Kristofer
    Tai, An
    Ahunbay, Ergun
    Erickson, Beth
    Schultz, Christopher J.
    Li, X. Allen
    MEDICAL PHYSICS, 2023, 50 (03) : 1766 - 1778
  • [43] Unified Registration Framework for Cumulative Dose Assessment in Cervical Cancer across External Beam Radiotherapy and Brachytherapy
    Roy, Sharmili
    Totman, John J.
    Choo, Bok A.
    MEDICAL IMAGING 2016: IMAGE PROCESSING, 2016, 9784
  • [44] Use of a DVH overlay technique for quality assurance of deformable image registration-based dose accumulation
    Kainz, Kristofer
    Garcia Alvarez, Juan
    Zhong, Hualiang
    Lim, Sara
    Ahunbay, Ergun
    Tai, An
    Erickson, Beth
    Lawton, Colleen
    Li, X. Allen
    MEDICAL PHYSICS, 2022, 49 (01) : 611 - 623
  • [45] A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration
    Hub, Martina
    Thieke, Christian
    Kessler, Marc L.
    Karger, Christian P.
    MEDICAL PHYSICS, 2012, 39 (04) : 2186 - 2192
  • [46] Accuracy of dose calculation on iterative CBCT for head and neck radiotherapy
    Washio, Hayate
    Ohira, Shingo
    Funama, Yoshinori
    Ueda, Yoshihiro
    Isono, Masaru
    Inui, Shoki
    Miyazaki, Masayoshi
    Teshima, Teruki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 106 - 112
  • [47] A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations
    Yan, C.
    Hugo, G.
    Salguero, F. J.
    Saleh-Sayah, N.
    Weiss, E.
    Sleeman, W. C.
    Siebers, J. V.
    MEDICAL PHYSICS, 2012, 39 (04) : 2119 - 2128
  • [48] Developments in deep learning based corrections of cone beam computed tomography to enable dose calculations for adaptive radiotherapy
    Taasti, Vicki Trier
    Klages, Peter
    Parodi, Katia
    Muren, Ludvig Paul
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 15 : 77 - 79
  • [49] Impact of deformable image registration on dose accumulation applied electrocardiograph-gated 4DCT in the heart and left ventricular myocardium during esophageal cancer radiotherapy
    Tong, Ying
    Yin, Yong
    Cheng, Pinjing
    Gong, Guanzhong
    RADIATION ONCOLOGY, 2018, 13
  • [50] Dose mapping: Validation in 4D dosimetry with measurements and application in radiotherapy follow-up evaluation
    Zhang, Geoffrey G.
    Huang, Tzung-Chi
    Forster, Ken M.
    Lin, Kang-Ping
    Stevens, Craig
    Harris, Eleanor
    Guerrero, Thomas
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2008, 90 (01) : 25 - 37