Applicability and usage of dose mapping/accumulation in radiotherapy

被引:31
|
作者
Murr, Martina [1 ]
Brock, Kristy K. [2 ,3 ]
Fusella, Marco [4 ]
Hardcastle, Nicholas [5 ,6 ]
Hussein, Mohammad [7 ]
Jameson, Michael G. [8 ]
Wahlstedt, Isak [9 ,10 ,11 ]
Yuen, Johnson [12 ,13 ,14 ]
McClelland, Jamie R. [15 ]
Osorio, Eliana Vasquez [16 ]
机构
[1] Univ Tubingen, Dept Radiat Oncol, Sect Biomed Phys, Tubingen, Germany
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
[4] Abano Terme Hosp, Dept Radiat Oncol, Abano Terme, Italy
[5] Univ Melbourne, Peter MacCallum Canc Ctr, Phys Sci, Melbourne, Vic, Australia
[6] Univ Melbourne, Sir Peter MacCallum Dept Oncol, Melbourne, Vic, Australia
[7] Natl Phys Lab, Metrol Med Phys Ctr, Teddington, Middx, England
[8] Univ New South Wales, Fac Med & Hlth, Sch Clin Med, GenesisCare New South Wales, Sydney, Australia
[9] Tech Univ Denmark, Dept Hlth Technol, Anker Engelunds Vej 1,Bygning 101A, DK-2800 Kongens Lyngby, Denmark
[10] Rigshosp RH, Copenhagen Univ Hosp, Ctr Canc & Organ Dis, Dept Oncol, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
[11] Copenhagen Univ Hosp Herlev & Gentofte HGH, Dept Oncol, Borgmester Ib Juuls Vej 7, DK-2730 Herlev, Denmark
[12] St George Hosp, Canc Care Ctr, Kogarah, NSW 2217, Australia
[13] Univ New South Wales, South Western Clin Sch, Sydney, NSW, Australia
[14] Ingham Inst Appl Med Res, Sydney, NSW, Australia
[15] UCL, Ctr Med Image Comp & Wellcome, EPSRC Ctr Intervent & Surg Sci, Dept Med Phys & Biomed Engn, London, England
[16] Univ Manchester, Div Canc Sci, Fac Biol Med & Hlth, Manchester M20 4BX, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Dose mapping; accumulation; Deformable image registration (DIR); DIR uncertainties; Impact of dose mapping uncertainties; Anatomical changes; accumulation landscape  (DMAL); DEFORMABLE IMAGE REGISTRATION; ADAPTIVE RADIATION-THERAPY; VOXEL-BASED ANALYSIS; NONRIGID REGISTRATION; ACCUMULATION; LUNG; HEAD; UNCERTAINTIES; MOTION; INFORMATION;
D O I
10.1016/j.radonc.2023.109527
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Dose mapping/accumulation (DMA) is a topic in radiotherapy (RT) for years, but has not yet found its widespread way into clinical RT routine. During the ESTRO Physics workshop 2021 on "commissioning and quality assurance of deformable image registration (DIR) for current and future RT applications ", we built a working group on DMA from which we present the results of our discussions in this article. Our aim in this manuscript is to shed light on the current situation of DMA in RT and to highlight the issues that hinder consciously integrating it into clinical RT routine.As a first outcome of our discussions, we present a scheme where representative RT use cases are posi-tioned, considering expected anatomical variations and the impact of dose mapping uncertainties on patient safety, which we have named the DMA landscape (DMAL). This tool is useful for future reference when DMA applications get closer to clinical day-to-day use.Secondly, we discussed current challenges, lightly touching on first-order effects (related to the impact of DIR uncertainties in dose mapping), and focusing in detail on second-order effects often dismissed in the current literature (as resampling and interpolation, quality assurance considerations, and radiobio-logical issues). Finally, we developed recommendations, and guidelines for vendors and users. Our main point include: Strive for context-driven DIR (by considering their impact on clinical decisions/judgements) rather than perfect DIR; be conscious of the limitations of the implemented DIR algorithm; and consider when dose mapping (with properly quantified uncertainties) is a better alternative than no mapping.(c) 2023 The Author(s). Published by Elsevier B.V. Radiotherapy and Oncology 182 (2023) 1-11 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Evaluation of nonrigid registration models for interfraction dose accumulation in radiotherapy
    Janssens, Guillaume
    de Xivry, Jonathan Orban
    Fekkes, Stein
    Dekker, Andre
    Macq, Benoit
    Lambin, Philippe
    van Elmpt, Wouter
    MEDICAL PHYSICS, 2009, 36 (09) : 4268 - 4276
  • [2] Deformable image registration for dose mapping between external beam radiotherapy and brachytherapy images of cervical cancer
    Rigaud, B.
    Klopp, A.
    Vedam, S.
    Venkatesan, A.
    Taku, N.
    Simon, A.
    Haigron, P.
    de Crevoisier, R.
    Brock, K. K.
    Cazoulat, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11)
  • [3] Dose accumulation for MR-guided adaptive radiotherapy: From practical considerations to state-of-the-art clinical implementation
    McDonald, Brigid A.
    Zachiu, Cornel
    Christodouleas, John
    Naser, Mohamed A.
    Ruschin, Mark
    Sonke, Jan-Jakob
    Thorwarth, Daniela
    Letourneau, Daniel
    Tyagi, Neelam
    Tadic, Tony
    Yang, Jinzhong
    Li, X. Allen
    Bernchou, Uffe
    Hyer, Daniel E.
    Snyder, Jeffrey E.
    Bubula-Rehm, Edyta
    Fuller, Clifton D.
    Brock, Kristy K.
    FRONTIERS IN ONCOLOGY, 2023, 12
  • [4] Predictive dose accumulation for HN adaptive radiotherapy
    Lee, Donghoon
    Zhang, Pengpeng
    Nadeem, Saad
    Alam, Sadegh
    Jiang, Jue
    Caringi, Amanda
    Allgood, Natasha
    Aristophanous, Michalis
    Mechalakos, James
    Hu, Yu-Chi
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [5] EFFECT OF BREATHING MOTION ON RADIOTHERAPY DOSE ACCUMULATION IN THE ABDOMEN USING DEFORMABLE REGISTRATION
    Velec, Michael
    Moseley, Joanne L.
    Eccles, Cynthia L.
    Craig, Tim
    Sharpe, Michael B.
    Dawson, Laura A.
    Brock, Kristy K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 265 - 272
  • [6] Improving anatomical mapping of complexly deformed anatomy for external beam radiotherapy and brachytherapy dose accumulation in cervical cancer
    Osorio, Eliana M. Vasquez
    Kolkman-Deurloo, Inger-Karine K.
    Schuring-Pereira, Monica
    Zolnay, Andras
    Heijmen, Ben J. M.
    Hoogeman, Mischa S.
    MEDICAL PHYSICS, 2015, 42 (01) : 206 - 220
  • [7] Accumulation of the delivered dose based on cone-beam CT and deformable image registration for non-small cell lung cancer treated with hypofractionated radiotherapy
    Wang, Bin
    Wang, Da Quan
    Lin, Mao Sheng
    Lu, Shi Pei
    Zhang, Jun
    Chen, Li
    Li, Qi Wen
    Cheng, Zhang Kai
    Liu, Fang Jie
    Guo, Jin Yu
    Liu, Hui
    Qiu, Bo
    BMC CANCER, 2020, 20 (01)
  • [8] Dose Deformation and Accumulation for Adaptive Radiotherapy in Nasopharyngeal Carcinoma
    Zhou, Lu
    Zhang, Shuxu
    Yuan, Kehong
    Wang, Linjing
    Peng, Yingying
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 397 - 401
  • [9] Direct dose mapping versus energy/mass transfer mapping for 4D dose accumulation: fundamental differences and dosimetric consequences
    Li, Haisen S.
    Zhong, Hualiang
    Kim, Jinkoo
    Glide-Hurst, Carri
    Gulam, Misbah
    Nurushev, Teamour S.
    Chetty, Indrin J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (01) : 173 - 188
  • [10] Surface-Constrained Nonrigid Registration for Dose Monitoring in Prostate Cancer Radiotherapy
    Cazoulat, Guillaume
    Simon, Antoine
    Dumenil, Aurelien
    Gnep, Khemara
    de Crevoisier, Renaud
    Acosta, Oscar
    Haigron, Pascal
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (07) : 1464 - 1474