Outcomes of Cerebral Embolic Protection for Bicuspid Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Replacement

被引:12
作者
Zhang, Jiajun [2 ,3 ,4 ]
Li, Xiaoxing [5 ]
Tian, Rui [2 ,3 ,4 ]
Zong, Mengzhi [2 ,3 ,4 ]
Gu, Xinghua [6 ]
Xu, Feng [2 ,3 ,4 ]
Chen, Yuguo [1 ,2 ,3 ,4 ]
Li, Chuanbao [1 ,2 ,3 ,4 ]
机构
[1] Shandong Univ, Qilu Hosp, 107 Wenhua Xi Rd, Jinan 250012, Shandong, Peoples R China
[2] Shandong Univ, Qilu Hosp, Cheeloo Coll Med, Dept Emergency Med, Jinan, Shandong, Peoples R China
[3] Key Lab Emergency & Crit Care Med Shandong Prov, Jinan, Peoples R China
[4] Key Lab Cardiovasc Remodeling & Funct Res, Jinan, Peoples R China
[5] Dept Geriatr, Jinan, Peoples R China
[6] Dept Cardiac Surg, Jinan, Peoples R China
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2023年 / 12卷 / 12期
基金
中国国家自然科学基金;
关键词
aortic stenosis; bicuspid aortic valve; cerebral embolic protection; National Inpatient Sample; transcatheter aortic valve replacement; RANDOMIZED EVALUATION; IMPLANTATION; ASSOCIATION; DEVICE; STROKE; SYSTEM; TRENDS; RISK;
D O I
10.1161/JAHA.122.028890
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThere was limited high-quality evidence that illuminated the efficiency of cerebral embolic protection (CEP) use during transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve (BAV) stenosis. Methods and ResultsIn this retrospective cohort study, patients with BAV stenosis undergoing TAVR with or without CEP were identified by querying the National Inpatient Sample database. The primary end point was any stroke during the hospitalization. The composite safety end point included any in-hospital death and stroke. We applied propensity score-matched analysis to minimize standardized mean differences of baseline variables and compare in-hospital outcomes. From July 2017 to December 2020, 4610 weighted hospitalizations with BAV stenosis undergoing TAVR were identified, of which 795 were treated with CEP. There was a significant increase in the CEP use rate for BAV stenosis (P-trend <0.001). A total of 795 discharges with CEP use were propensity score matched to 1590 comparable discharges but without CEP. CEP use was associated with a lower incidence of in-hospital stroke (1.3% versus 3.8%; P<0.001), which in multivariable regression was also independently associated with the primary outcome (adjusted odds ratio=0.38 [95% CI, 0.18-0.71]; P=0.005) and the safety end point (adjusted odds ratio=0.41 [95% CI, 0.22-0.68] P=0.001). Meanwhile, no significant difference was found in the cost of hospitalization ($46 629 versus $45 147; P=0.18) or the risk of vascular complications (1.9% versus 2.5%; P=0.41). ConclusionsThis observational study supported CEP use for BAV stenosis, which was independently associated with less in-hospital stroke without burdening the patients with a high hospitalization cost.
引用
收藏
页数:23
相关论文
共 26 条
[1]   Early Experience With Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement in the United States [J].
Alkhouli, Mohamad ;
Alqahtani, Fahad ;
Harris, Alyssa Hartsell ;
Hohmann, Samuel F. ;
Rihal, Charanjit S. .
JAMA INTERNAL MEDICINE, 2020, 180 (05) :783-784
[2]  
Ciobanu AO, 2021, AM J THER, V28, pE560, DOI 10.1097/MJT.0000000000001413
[3]   Temporal Trends and Outcomes of Transcatheter Versus Surgical Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis [J].
Elbadawi, Ayman ;
Saad, Marwan ;
Elgendy, Islam Y. ;
Barssoum, Kirolos ;
Omer, Mohamed A. ;
Soliman, Ahmed ;
Almahmoud, Mohamed F. ;
Ogunbayo, Gbolahan O. ;
Mentias, Amgad ;
Gilani, Syed ;
Jneid, Hani ;
Aronow, Herbert D. ;
Kleiman, Neil ;
Abbott, J. Dawn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (18) :1811-1822
[4]   Brain Injury After Transcatheter Replacement of Bicuspid Versus Tricuspid Aortic Valves [J].
Fan, Jiaqi ;
Fang, Xian ;
Liu, Chunhui ;
Zhu, Gangjie ;
Hou, Cody R. ;
Jiang, Jubo ;
Lin, Xinping ;
Wang, Lihan ;
He, Yuxin ;
Zhu, Qifeng ;
Ng, Stella ;
Chen, Zexin ;
Hu, Haitao ;
Liu, Xianbao ;
Wang, Jian'an ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (22) :2579-2590
[5]   Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis The CLEAN-TAVI Randomized Clinical Trial [J].
Haussig, Stephan ;
Mangner, Norman ;
Dwyer, Michael G. ;
Lehmkuhl, Lukas ;
Luecke, Christian ;
Woitek, Felix ;
Holzhey, David M. ;
Mohr, Friedrich W. ;
Gutberlet, Matthias ;
Zivadinov, Robert ;
Schuler, Gerhard ;
Linke, Axel .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (06) :592-601
[6]  
Healthcare Cost and Utilization Project, 2022, NATL NATIONWIDE INPA
[7]   Association Between Transcatheter Aortic Valve Replacement and Early Postprocedural Stroke [J].
Huded, Chetan P. ;
Tuzcu, E. Murat ;
Krishnaswamy, Amar ;
Mick, Stephanie L. ;
Kleiman, Neal S. ;
Svensson, Lars G. ;
Carroll, John ;
Thourani, Vinod H. ;
Kirtane, Ajay J. ;
Manandhar, Pratik ;
Kosinski, Andrzej S. ;
Vemulapalli, Sreekanth ;
Kapadia, Samir R. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2019, 321 (23) :2306-2315
[8]   Cerebral Embolic Protection and Stroke-Related Mortality Following Transcatheter Aortic Valve Replacement [J].
Isogai, Toshiaki ;
Bansal, Agam ;
Vanguru, Husitha Reddy ;
Agrawal, Ankit ;
Shekhar, Shashank ;
Puri, Rishi ;
Reed, Grant W. ;
Krishnaswamy, Amar ;
Uchino, Ken ;
Kapadia, Samir R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (05) :569-571
[9]   Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement [J].
Kapadia, Samir R. ;
Kodali, Susheel ;
Makkar, Raj ;
Mehran, Roxana ;
Lazar, Ronald M. ;
Zivadinov, Robert ;
Dwyer, Michael G. ;
Jilaihawi, Hasan ;
Virmani, Renu ;
Anwaruddin, Saif ;
Thourani, Vinod H. ;
Nazif, Tamim ;
Mangner, Norman ;
Woitek, Felix ;
Krishnaswamy, Amar ;
Mick, Stephanie ;
Chakravarty, Tarun ;
Nakamura, Mamoo ;
McCabe, James M. ;
Satler, Lowell ;
Zajarias, Alan ;
Szeto, Wilson Y. ;
Svensson, Lars ;
Alu, Maria C. ;
White, Roseann M. ;
Kraemer, Carlye ;
Parhizgar, Azin ;
Leon, Martin B. ;
Linke, Axel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (04) :367-377
[10]   Cerebral Embolic Protection during Transcatheter Aortic-Valve Replacement [J].
Kapadia, Samir R. R. ;
Makkar, Raj ;
Leon, Martin ;
Abdel-Wahab, Mohamed ;
Waggoner, Thomas ;
Massberg, Steffen ;
Rottbauer, Wolfgang ;
Horr, Samuel ;
Sondergaard, Lars ;
Karha, Juhana ;
Gooley, Robert ;
Satler, Lowell ;
Stoler, Robert C. ;
Messe, Steven R. ;
Baron, Suzanne J. ;
Seeger, Julia ;
Kodali, Susheel ;
Krishnaswamy, Amar ;
Thourani, Vinod H. ;
Harrington, Katherine ;
Pocock, Stuart ;
Modolo, Rodrigo ;
Allocco, Dominic J. ;
Meredith, Ian T. ;
Linke, Axel ;
PROTECTED TAVR Investigators .
NEW ENGLAND JOURNAL OF MEDICINE, 2022, 387 (14) :1253-1263