Prediction of post-fire seismic performance of reinforced concrete frames

被引:10
作者
Kamalvand, Morteza [1 ]
Massumi, Ali [1 ]
Homami, Peyman [1 ]
机构
[1] Kharazmi Univ, Fac Engn, Dept Civil Engn, Tehran, Iran
关键词
RC frame; Post-fire seismic resistance; Heat transfer analysis; Residual capacity; Bond-slip; PLASTIC-DAMAGE MODEL; NUMERICAL-ANALYSIS; RESIDUAL STRENGTH; EXPOSURE; BEAMS; BEHAVIOR; TEMPERATURES; COLUMNS; STEELS;
D O I
10.1016/j.istruc.2023.104874
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the importance of evaluating the seismic behavior of structures after a fire, a numerical study was conducted on RC frames using the detailed finite element method. The simulation process consists of two separate steps. The first step is heat transfer analysis to estimate heat distribution in the various elements of RC frames, and the second step is evaluating the post-fire seismic performance of the frames using thermal-mechanical analysis. The test specimens used to verify the proposed FE model include two RC frames with different beam-column bending capacity ratios, which are in two different conditions, including the specimens at ambient temperature as control specimens and fired specimens inside of the furnace chamber. In the heat transfer analysis step, the sensitivity of responses to two effective parameters, including the moisture content and the emissivity of the concrete surface has been investigated. In the post-fire analysis, among the various models presented for the post-fire behavior of concrete, three stress-strain models were selected for cyclic analysis of RC frames and the results were compared with the test data. Also, the bond-slip behavior of the concrete-steel interface has been simulated using the equivalent springs technique. It was seen from the comparison of the numerical results with the test data, that the proposed model accurately estimates the resistance and the dissipated energy of frames in each cycle. In addition, parametric studies showed that every 30 min increase in the fire duration based on the ISO 834 standard curve causes a 10% decrease in post-fire seismic resistance compared to the control specimen.
引用
收藏
页数:15
相关论文
共 59 条
[21]   Concrete strength for fire safety design [J].
Hertz, KD .
MAGAZINE OF CONCRETE RESEARCH, 2005, 57 (08) :445-453
[22]  
Hognestad E., 1951, BULLETIN, V399, P1
[23]  
Hu C.P., 2014, J HUAQIAO U NATURAL, V35, P196, DOI 10.11830/ISSN.1000-5013.2014.02
[24]   An approach for evaluating residual capacity of reinforced concrete beams exposed to fire [J].
Kodur, V. K. R. ;
Agrawal, Ankit .
ENGINEERING STRUCTURES, 2016, 110 :293-306
[25]  
Kordina K, 1985, PROCEEDING 1 INT S F, P281
[26]   Plastic-damage model for cyclic loading of concrete structures [J].
Lee, JH ;
Fenves, GL .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1998, 124 (08) :892-900
[27]  
Lemaitre J., 1990, Mechanics of Solid Materials, V1st
[28]   Residual mechanical properties of high strength steels after exposure to fire [J].
Li, Hai-Ting ;
Young, Ben .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 148 :562-571
[29]   Experimental study on seismic performance of post-fire reinforced concrete frames [J].
Li, Ling-Zhi ;
Liu, Xin ;
Yu, Jiang-Tao ;
Lu, Zhou-Dao ;
Su, Mei-Ni ;
Liao, Jie-Hong ;
Xia, Min .
ENGINEERING STRUCTURES, 2019, 179 :161-173
[30]   Fire Performance of Steel-Reinforced Ultrahigh-Toughness Cementitious Composite Columns: Experimental Investigation and Numerical Analyses [J].
Li, Qing-Hua ;
Sun, Chao-Jie ;
Lyu, Jun-Feng ;
Quan, Guan ;
Huang, Bo-Tao ;
Xu, Shi-Lang .
JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (03)